Maria Cecília Gontijo Ramos
Institute/School/College
Knowledge Area
Date of Defense
Published
São Carlos, 2022
Supervisor
Committee
Roma, Woodrow Nelson Lopes (President)
Achon, Cali Laguna
Kellner, Erich
Title in Portuguese
Otimização operacional de um setor de abastecimento de água por meio da alteração dos volumes dos reservatórios de água tratada
Keywords in Portuguese
custo de energia
otimização combinatória
otimização multiobjetivo
redes de abastecimento de água
reservatórios de distribuição
Abstract in Portuguese
Em 2018, 89% do consumo energético dos prestadores de serviço de saneamento no Brasil foram destinados ao abastecimento de água, que representou 14,5% do total das despesas (SNIS, 2018). Na operadora de água do município do São Carlos - SP, esse percentual foi de 21,5%. Uma maneira de reduzir o custo de energia em um sistema de abastecimento de água é através de alteração operacional dos sistemas bombeamento-reservação, podendo-se ampliar o volume de armazenamento para deslocar o consumo de energia em que são cobradas as maiores tarifas para os horários em que as tarifas são mais baratas. Por outro lado, os reservatórios representam uma parcela bastante pequena do total de custos para manutenção e operação da rede. No entanto, seu impacto no desempenho geral da rede é significativo, desproporcional aos seus custos. Nessa pesquisa, foi desenvolvido um modelo de otimização que visa minimizar o custo energético, a partir da alteração das capacidades dos reservatórios de distribuição de água. Dessa forma, foi proposto um modelo computacional - MOC (Modelo de Otimização Combinatória), empregando algoritmo Guloso (ou de Prim) e um simulador hidráulico e de qualidade da água fundamentado no EPANET 2.2, que foi aplicado ao modelo hidráulico de um setor de abastecimento de São Carlos-SP. Dado que o sistema de abastecimento estudado possui 3 subsistemas e estes podem operar de forma independente ou interligada, foram realizadas análises para esses dois cenários. Mesmo no cenário que resultou em menor compensação financeira, estima-se que a economia de energia compensaria o custo a mais na implantação dos reservatórios dentro de 4 a 5 anos. No melhor cenário, essa compensação ocorreria em um ano.
Title in English
Operational optimization of a water distribution network by changing service water reservoirs' capacities
Keywords in English
combinatorial optimization
energy costs
multi-objective optimization
service reservoirs
water distribution networks
water tanks
Abstract in English
In 2018, 89% of the energy consumption of sanitation service providers in Brazil was destined for water supply, which represented 14.5% of total expenses (SNIS, 2018). At the water operator in São Carlos - SP, this percentage was 21.5%. One way to reduce energy costs in a water supply network is through operational changes in the pumping-reservoir systems, with the possibility of expanding the storage volume to shift the energy consumption from peak electricity tariffs periods to off-peak electricity tariffs periods. On the other hand, water tanks represent a very small portion of the total costs of network maintenance and operation. However, its impact on overall network performance is significant, out of proportion to its costs. In this research, an optimization model was developed that aims to minimize energy costs, by changing service reservoirs' storage capacities. Therefore, a computational model was proposed, named MCO (Model of Combinatorial Optimization), employing greedy (or Prim's) algorithm and a hydraulic and water quality simulator based on EPANET 2.2. The optimization model was then applied to the hydraulic model of a supply sector in São CarlosSP. Since there were 3 subsystems in the water supply sector studied and they can operate independently or connected, analyzes were carried out for these two scenarios. Even in the scenario that resulted in lower financial compensation, it is estimated that the energy savings would offset the extra cost of implementing the reservoirs within 4 to 5 years. In the best-case scenario, this compensation would occur in one year.
 
WARNING - Viewing this document is conditioned on your acceptance of the following terms of use:
This document is only for private use for research and teaching activities. Reproduction for commercial use is forbidden. This rights cover the whole data about this document as well as its contents. Any uses or copies of this document in whole or in part must include the author's name.
Publishing Date
2022-08-23
 
WARNING: Learn what derived works are clicking here.
All rights of the thesis/dissertation are from the authors
CeTI-SC/STI
Digital Library of Theses and Dissertations of USP. Copyright © 2001-2024. All rights reserved.