Titre en portugais
Remoção de fitoplancton e microcistina de águas de abastecimento, pela associação das técnicas de flotação por ar dissolvido e oxidação química com cloro e permanganato de potássio
Mots-clés en portugais
Flotação por ar dissolvido
Oxidação química com permanganato de potássio e cloro
Remoção de fitoplancton
Remoção de microcistina
Remoção e formação de trihalometanos
Resumé en portugais
O presente trabalho de pesquisa teve como objetivo principal avaliar a remoção de fitoplancton e microcistina em cinco fluxogramas de tratamento de água para abastecimento, que tiveram como seqüência básica as etapas de coagulação, floculação, flotação por ar dissolvido e filtração, complementados com oxidação química em diferentes pontos da seqüência básica de tratamento estabelecida. Os ensaios foram realizados em escala de laboratório, utilizando água de estudo preparada mediante a mistura de água coletada no reservatório de Barra Bonita, no Estado de São Paulo, e cultura com elevada concentração de microcistina preparada em laboratório. A concentração de microcistina na água de estudo foi mantida no intervalo de 14 a 17 µg/L. O cloreto férrico foi utilizado como agente coagulante, o permanganato de potássio e o cloro, na forma de hipoclorito de sódio, foram utilizados como agentes oxidantes. Foi observada eficiência de remoção de fitoplancton de cerca de 99,9% devido às etapas de coagulação, floculação e flotação por ar dissolvido e, conseqüentemente, remoção de microcistina contida no interior das células íntegras. A oxidação com cloro realizada após a filtração, bem como a oxidação com a associação do permanganato de potássio e cloro realizada após a flotação, resultaram em eficiência de remoção de microcistina extracelular (microcistina livre no meio líquido) da ordem de 95%, atendendo ao padrão de potabilidade com cocentrações de microcistina menores que 1,0 µg/L. A oxidação da água bruta com permanganato de potássio associada à oxidação da água flotada com cloro, apresentou o melhor desempenho de remoção de microcistina extracelular, com eficiência superior a 98%. Em todos os ensaios de oxidação química foi constatada a influência da variação do pH na remoção de microcistina, sendo que o aumento de eficiência foi associado à diminuição dos valores de pH. Foram observados indícios de remoção de trihalometanos pela flotação por ar dissolvido e redução da formação de trihalometanos quando a oxidação química foi feita com a associação do permanganato de potássio e cloro.
Titre en anglais
Removal of phytoplankton and microcystin from source water, by assotiation of dissolved air flotation and chemical oxidation with potassium permanganate and chlorine
Mots-clés en anglais
Chlorine oxidation
Dissolved air flotation
Microcystin removal
Phytoplankton removal
Potassium permanganate oxidation
THM's production
THM's removal
Resumé en anglais
The aim of this research was to study the phytoplankton and microcystin removal at different treatment conditions, all based in coagulation, flocculation, dissolved air flotation and filtration, complemented by chemical oxidation applied at different points of the basic treatment sequency. The lab scale experiments was conduted with raw water prepared by a mixture of natural water, collected in Barra Bonita reservoir at São Paulo State, Brazil, and a high concentrated Microcystis culture prepared in laboratory. The microcystin concentration in raw water was kept in a range of 14 to 17 µg/L. Ferric chloride was used as coagulant, and, potassium permanganate and chlorine (sodium hypochlorite) were used as oxidants. The results showed phytoplankton removal efficiency about 99,9% by the sequency of coagulation, flocculation and dissolved air flotation, resulting a great removal of microcystin retained into the whole cells. The chlorine oxidation after filtration, as well as the oxidation with potassium permanganate and chlorine after dissolved air flotation, resulted in a microcystin removal of about 95% and concentrations under the World Health Organization drinking water guideline value of 1,0 µg/L. The raw water potassium permanganate oxidation associated with the chlorine oxidation after flotation, leaded to the best results concerning microcystin removal, with efficiency above 98%. All experimental conditions with chemical oxidation showed a relevant effect of the pH on the microcystin removal, the decrease of pH values contributed to the increase of microcystin removal. It was observed signs of THM´s removal by the dissolved air flotation and reduction of THM´s production when the chemical oxidation took place with the association of potassium permanganate and chlorine.
 
AVERTISSEMENT - Regarde ce document est soumise à votre acceptation des conditions d'utilisation suivantes:
Ce document est uniquement à des fins privées pour la recherche et l'enseignement. Reproduction à des fins commerciales est interdite. Cette droits couvrent l'ensemble des données sur ce document ainsi que son contenu. Toute utilisation ou de copie de ce document, en totalité ou en partie, doit inclure le nom de l'auteur.
Date de Publication
2008-09-15
 
AVERTISSEMENT: Apprenez ce que sont des œvres dérivées cliquant ici.
Tous droits de la thèse/dissertation appartiennent aux auteurs
CeTI-SC/STI
Bibliothèque Numérique de Thèses et Mémoires de l'USP. Copyright © 2001-2024. Tous droits réservés.