Mémoire de Maîtrise
DOI
https://doi.org/10.11606/D.18.2012.tde-17102012-103326
Document
Auteur
Nom complet
Irene Monteiro da Franca Souza
Adresse Mail
Unité de l'USP
Domain de Connaissance
Date de Soutenance
Editeur
São Carlos, 2012
Directeur
Jury
Reali, Marco Antonio Penalva (Président)
Cordeiro, João Sérgio
Daniel, Luiz Antonio
Titre en portugais
Influência do gradiente médio de velocidade na zona de contato na eficiência de clarificação de água para abastecimento por flotação
Mots-clés en portugais
Flotação por ar dissolvido (FAD)
Gradiente médio de velocidade (G)
Telas
Tratamento de água para abastecimento
Zona de contato e zona de separação
Resumé en portugais
O presente trabalho teve como objetivo estudar a influência do gradiente médio de velocidade (Gzc), associado ao tempo de detenção hidráulico (tzc) e à taxa de aplicação superficial (TASzc), na zona de contato, na eficiência de clarificação de uma unidade retangular de flotação por ar dissolvido, em escala piloto, tratando água para abastecimento. Foram estudadas duas configurações da Unidade Piloto de Flotação por Ar Dissolvido (UPFAD) (A e B), as quais diferem no comprimento da zona de contato A (90 mm) e B (140 mm). A TASzc - A (133 ± 3 m/h) e B (86 ± 1 m/h) - e o tzc - A (54 ± 1s) e B (84 ± 1 s) - são diferentes. Foram avaliados três valores do Gzc A (1,8; 6,5;10,2) e B (0,9; 4,7; 6,3), através da inserção de telas com características diferentes no interior da zona de contato. E, Para cada valor de Gzc, foram investigados três valores de A/V (3,73; 4,90; 6,41). Em todos os ensaios realizados, foram fixados os seguintes parâmetros: vazão da água bruta preparada (5,4 m³/h); temperatura da água bruta preparada (26 ± 1ºC); pH de coagulação (6,5 ± 0,1); tempo de floculação (17,2 min); gradiente médio de velocidade de floculação (110 s-1); vazão de descarte após a floculação (0,8 m³/h); vazão de entrada para a flotação (Qe) (4,6 m³/h); velocidade de entrada para a flotação (ve) (180 m/h); velocidade cross-flow (45 m/h); TASzs (14,6 ± 0,2 m/h); pressão de saturação (4,5 ± 0,1 Kgf/cm²). A unidade piloto FAD foi alimentada com água preparada, que apresentou turbidez em torno de 7,4 ± 0,6 UNT, e cor aparente, em torno de 39,4 ± 4,3 UH. A fração removida dos parâmetros analisados para cada Gzc é menos sensível a variações de A/V na configuração A que na configuração B. Na configuração A, a tela que apresentou Gzc em torno de 6,5 s-1 gerou melhores resultados para cada A/V analisado. Na configuração B, a tela que gerou Gzc em torno de 4,7 s-1 proporcionou melhor fração removida de turbidez e cor para cada A/V estudado. Além disso, na configuração B, a fração removida de turbidez e cor foi menos sensível a variações de A/V, para Gzc de 4,7 s-1 que para os demais valores de Gzc. A tela que gerou resultados mais eficientes na configuração A foi a mesma para a configuração B. Portanto o uso da referida tela favoreceu o desempenho das configurações A e B. Comparando todas as situações estudadas nas duas configurações, o ensaio com a configuração A (com tzc de 54 s) com Gzc de 6,3 s-1 e A/V de 4,9 g/m³, apresentou as maiores frações de remoção de cor e turbidez.
Titre en anglais
Influence of the velocity gradient in the contact zone in the efficiency of clarification of potable water by flotation
Mots-clés en anglais
Contact zone and separation zone
Dissolved air flotation (DAF)
Grilles
Treatment of potable water
Velocity gradient (G)
Resumé en anglais
The present work aimed to study the influence of velocity gradient (Gzc) associated with the hydraulic detention time (tzc) and the rate of surface application (TASzc) in the contact zone in the efficiency of clarification of a unit rectangular dissolved air flotation pilot scale, treating water supplies. Two different kinds of configurations of the reactor dissolved air flotation in pilot scale (UPFA) (A and B) were studied, which differ in the length of the contact zone - A (90 mm) and B (140 mm). The TASzc - A (133 ± 3 m/h) and B (86 ± 1 m/h) - and tzc - A (54 ± 1 s) and B (84 ± 1 s) were different. Three different values of Gzc were analysed - A (1.8, 6.5, 10.2 s-1) and B (0.9, 4.7, 6.3 s-1) by insertion of grilles with different characteristics within the zone contact. And for each value of Gzc, three values of A/V (3.73, 4.90, 6.41 g/m³) were investigated. In all trials, the following parameters were set: flow of synthetic raw water (5.4 m³/h), synthetic raw water temperature (26 ± 1ºC), coagulation pH (6.5 ± 0.1); flocculation time (17.2 minutes), the speed gradient flocculation (110 s-1); flow disposal after flocculation (0.8 m³/h), input flow to the flotation (Qe) (4, 6 m³/h), input speed for flotation (ve) (180 m/h), cross-flow velocity (45 m/h), TASzs (14.6 ± 0.2 m/h), saturation pressure (4.5 ± 0.1 kgf/cm ²). The pilot plant was fed with synthetic water, which showed turbidity of approximately 7.4 ± 0.6 NTU, and apparent color, about 39.4 ± 4.3 HU. The removal efficiency of the analyzed parameters for each Gzc is less sensitive to variations in the A/V in the configuration A than in the configuration B. In configuration A, the grille that showed Gzc about 6.5 s-1 gave better results for each A/V analysis. In configuration B, the grille that has generated Gzc around 4.7 s-1 provided the best removal efficiency of turbidity and color for each A/V studied. Furthermore, in the configuration B, the removal efficiency of color and turbidity was less sensitive to variations in A/V for Gzc 4.7 s-1 than for other values of Gzc. The grille that generated the best results in the configuration A was the same for the configuration B. Therefore the use of that grille favored the performance of configurations A and B. Comparing all the situations studied in two configurations, the test with the configuration A (with tzc the 54 s) with Gzc of 6.3 s-1 and A/V of 4.9 g/m³, had the highest removal efficiencies of color and turbidity.
 
AVERTISSEMENT - Regarde ce document est soumise à votre acceptation des conditions d'utilisation suivantes:
Ce document est uniquement à des fins privées pour la recherche et l'enseignement. Reproduction à des fins commerciales est interdite. Cette droits couvrent l'ensemble des données sur ce document ainsi que son contenu. Toute utilisation ou de copie de ce document, en totalité ou en partie, doit inclure le nom de l'auteur.
Date de Publication
2012-10-18
 
AVERTISSEMENT: Apprenez ce que sont des œvres dérivées cliquant ici.
Tous droits de la thèse/dissertation appartiennent aux auteurs
CeTI-SC/STI
Bibliothèque Numérique de Thèses et Mémoires de l'USP. Copyright © 2001-2024. Tous droits réservés.