Master's Dissertation
DOI
https://doi.org/10.11606/D.18.2018.tde-16072018-163959
Document
Author
Full name
Patrícia Bilotta Monaco
Institute/School/College
Knowledge Area
Date of Defense
Published
São Carlos, 2000
Supervisor
Committee
Povinelli, Jurandyr (President)
Daniel, Luiz Antonio
Rezende, Maria Olímpia de Oliveira
Title in Portuguese
Estudo comparativo da ação do ozônio e radiação UV na desinfecção de esgoto sanitário
Keywords in Portuguese
Desinfecção de esgoto sanitário
Ozônio
Radiação ultravioleta
Abstract in Portuguese
A desinfecção é sem dúvida uma das etapas mais importantes no tratamento de águas residuárias. Dentre as técnicas em uso na inativação de microrganismos presentes em águas de abastecimento e esgoto sanitário, destaca-se a ozonização c a radiação ultravioleta, tanto pela eficiência de ação como pela não geração de subprodutos como trihalometanos, potencialmente cancerígenos. O presente trabalho buscou investigar e interpretar, de modo comparativo, aspectos relevantes do desempenho da ozonização e da radiação UV na remoção de coliformes totais e coliformes fecais, quando aplicados ao esgoto sanitário efluente de tratamento anaeróbio. A fase experimental foi dividida em duas etapas principais. Na primeira delas deu-se a avaliação da técnica de ozonização, exigindo para tanto a elaboração e construção da estação piloto, bem como a instalação de unidades adicionais responsáveis pelo pré-tratamento do ar atmosférico anteriormente à sua entrada no equipamento gerador de ozônio. Nesta fase foram avaliadas as dosagens de 5, 8 e 10 mg O3/L, para os tempos de contato de 5, 10 e 15 minutos. Na etapa seguinte buscou-se examinar a inativação de microrganismos mediante a aplicação de radiação ultravioleta, o que demandou o projeto e construção do reator fotoquímico empregado nos ensaios. Nesta etapa experimental a intensidade de radiação incidente, bem como a espessura de lâmina líquida, foram mantidas constantes, para os diferentes tempos de exposição investigados (10, 20, 40 e 60 segundos). Os ensaios de desinfecção foram seguidos de análises e exames da concentração de sólidos suspensos totais (SST), determinação do número mais provável de coliformes totais (CT) e coliformes fecais (CF), alcalinidade, pH e temperatura, demanda química de oxigênio (DQO) e carbono orgânico total (COT). No contexto dos aspectos observados ao longo desta pesquisa, concluiu-se, para as condições avaliadas, a superioridade da inativação de coliformes totais e coliformes fecais com o uso da radiação ultravioleta. Além disso, a técnica demonstrou vantagens, em relação a ozonização, no que concerne ao modo de operação, influência da qualidade do efluente bruto, controle do processo, entre outras.
Title in English
not available
Keywords in English
not available
Abstract in English
Disinfection is certainly among the most important phases in wastewater treatment. From the techniques in use today for inactivation of microorganisms present in either water supply of sanitary sewer, the ozonization and the ultraviolet radiation are worthy to be noticed due to both their action efficiency and the non generation of byproducts such as trihalomethanes, potentially cancerous. In this work we aim to investigate and interpret, in a comparative basis, relevant aspects on both ozonization and UV radiation performance in total and fecal coliform remotion when applied to sanitary sewer effluent from anaerobic treatment. The experimental phase comprises of two main steps. The first one was devoted to the evaluation of ozonization technique, for which it was necessary to build the pilot-station, as well as to set up additional unities responsible for the pre-treatment of atmospheric air prior to its entrance into the ozone generator. In this phase doses of 5, 8 and 10 mg O3/L were essayed for contact times of 5, 10 and 15 minutes. The second step 's goal was to examine microorganism inactivation through application of UV radiation, for which the design and implementation of the photochemical reactor used during the essays were necessary. In the experimental procedures the incident-radiation intensity, as well as the liquid layer thickness were kept constant for the several exposition time investigated (10, 20, 40 and 60 seconds). The disinfection essays were followed by exams and analysis of total suspended solid (TSS), most probable number of total (TC) and fecal (FC) coliforms, alkalinity, pH and temperature, chemical oxygen demand (COD) and total organic carbon (TOC). In the context of lhe observed aspects during this research work it was possible to notice, for the evaluated conditions, the UV radiation superiority in the total and fecal coliform inactivation. Also, this technique has shown to offer advantages when likened to ozonization regarding to operational complexity, influence of raw effluent quality, process control and other parameters.
 
WARNING - Viewing this document is conditioned on your acceptance of the following terms of use:
This document is only for private use for research and teaching activities. Reproduction for commercial use is forbidden. This rights cover the whole data about this document as well as its contents. Any uses or copies of this document in whole or in part must include the author's name.
Publishing Date
2018-07-17
 
WARNING: Learn what derived works are clicking here.
All rights of the thesis/dissertation are from the authors
CeTI-SC/STI
Digital Library of Theses and Dissertations of USP. Copyright © 2001-2024. All rights reserved.