• JoomlaWorks Simple Image Rotator
  • JoomlaWorks Simple Image Rotator
  • JoomlaWorks Simple Image Rotator
  • JoomlaWorks Simple Image Rotator
  • JoomlaWorks Simple Image Rotator
  • JoomlaWorks Simple Image Rotator
  • JoomlaWorks Simple Image Rotator
  • JoomlaWorks Simple Image Rotator
  • JoomlaWorks Simple Image Rotator
  • JoomlaWorks Simple Image Rotator
 
  Bookmark and Share
 
 
Doctoral Thesis
DOI
https://doi.org/10.11606/T.18.2016.tde-12092016-102929
Document
Author
Full name
Luci Sartori
E-mail
Institute/School/College
Knowledge Area
Date of Defense
Published
São Carlos, 2004
Supervisor
Committee
Daniel, Luiz Antonio (President)
Campos, José Roberto
Guimarães, José Roberto
Piveli, Roque Passos
Souza, Clovis Wesley Oliveira de
Title in Portuguese
Adequação da qualidade microbiológica de efluentes de tratamento secundário de esgoto sanitário pela aplicação dos desinfetantes ozônio, permanganato de potássio e ácido peracético
Keywords in Portuguese
Ácido peracético
Microrganismos indicadores
Ozônio
Permanganato de potássio
Reúso
Abstract in Portuguese
Esta pesquisa abordou a influência do ozônio, ácido peracético e permanganato de potássio na inativação dos microrganismos indicadores E.coli, colifago, C.perfringens e Ascaris lumbricoides de efluentes secundários, visando reúso em agricultura. Os efluentes utilizados para os ensaios com ozônio foram provenientes da Estação de Tratamento de Esgoto da cidade de Lins-SP (o tratamento consiste em lagoa anaeróbia seguida de facultativa) e da Estação de Tratamento de Esgoto da cidade de Araraquara-SP, na qual o tratamento é constituído de lagoa aerada seguida de lagoa de sedimentação. Para os ensaios de desinfecção com ácido peracético e permanganato de potássio utilizou-se apenas o efluente da Estação de Tratamento de Esgoto da cidade de Araraquara-SP. Os ensaios de desinfecção demonstraram que o ácido peracético tem maior poder bactericida em relação ao ozônio e permanganato de potássio. O ozônio foi mais eficiente na inativação do microrganismo colifago. Para todos os desinfetantes usados, a concentração da bactéria esporulada C.perfringens permaneceu entre 103 a 104 NMP/100 mL. Todos os desinfetantes, nas concentrações e tempos de contatos testados, mostraram-se tóxicos nas primeiras 24 h ao microcrustáceo Daphnia similis. O desinfetante que alcançou, com menor concentração e tempo de contato, o padrão proposto pela OMS (1989) para irrigação irrestrita foi o ácido peracético com 5 mg/L e tempo de contato de 10 minutos. Já a concentração de ozônio consumida de 40 mg/L e tempo de contato de 10 minutos foram suficientes para atender ao padrão proposto para irrigação restrita.
Title in English
Microbiological quality adequation of the wastewater secondary effluent by the application of ozone, potassium permanganate and peracetic acid desinfectants
Keywords in English
Indicator microorganisms
Ozone
Peracetic acid
Potassium permanganate
Reuse
Abstract in English
This research deals with the influence of ozone, peracetic acid and potassium permanganate on the inactivation of indicator microorganisms E.coli, coliphage, Clostridium perfringens and Ascaris lumbricoides secondary effluents, aiming agricultural reuse. The effluents used for the analyses with ozone had been proceeding from the Lins-SP Wastewater Treatment Plant (the treatment consists of an anaerobic lagoon followed by a facultative one) and from the Araraquara-SP Wastewater Treatment Plant, where the treatment consists of an aerated lagoon followed by a sedimentation pond. For the disinfection analyses with peracetic acid and potassium permanganate only the effluent from the Araraquara-SP Wastewater Treatment Plant was used. The disinfection analyses demonstrated that the peracetic acid has greater bactericide power than ozone and potassium permanganate. Ozone was more efficient in the coliphage microorganism inactivation. For all used disinfectants the concentration of sporulated bacteria Clostridium perfringens remained between 103 and 104 NPM/100 mL. All the disinfectants, under the concentration and contact time tested, showed themselves toxic during the first 24 h, and did not show any mortality to the Daphnia similis microorganism after that period. The disinfectant that reached, under lower concentration and contact time, the proposed standard for unrestricted irrigation from WHO (1989) was the peracetic acid with 5 mg/L and contact time of 10 minutes.
 
WARNING - Viewing this document is conditioned on your acceptance of the following terms of use:
This document is only for private use for research and teaching activities. Reproduction for commercial use is forbidden. This rights cover the whole data about this document as well as its contents. Any uses or copies of this document in whole or in part must include the author's name.
Tese_Sartori_Luci.pdf (43.02 Mbytes)
Publishing Date
2016-09-12
 
WARNING: The material described below relates to works resulting from this thesis or dissertation. The contents of these works are the author's responsibility.
  • SARTORI, Luci, DANIEL, L. A., y SCHULZ, Harry Edmar. Adequación de la Calidad Microbiológica de Desechos de Lagunas de Estabilización por la Aplicacion de Ozono [doi:10.4067/S0718-07642007000600011]. Información Tecnológica (Impresa) [online], 2007, vol. 18, p. 83-92.
  • SARTORI, Luci, and DANIEL, L. A. Microbiological quality adequation of effluents from secondary lagoons by the application of ozone. In 4th International symposium on wastewater reclamation and reuse, México, 2003. 4th International symposium on wastewater reclamation and reuse.Mexico : IWA - International Water Association, 2003.
  • SARTORI, Luci, e DANIEL, L. A. Resistência dos microrganismos indicadores Escherichia coli, colifagos e Clostridium perfringens frente à ação do ozônio como desinfetante utilizando efluente secundário de esgoto sanitário da ETE de Lins - SP. In 22 Congresso da Asssociação Brasileira de Engenharia Sanitária e Ambiental, Joinville - SC, 2003. 22 Congresso da Asssociação Brasileira de Engenharia Sanitária e Ambiental.Rio de Janeiro - RJ : ABES, 2003.
  • SOUZA, Jeanette Béber de, SARTORI, Luci, e DANIEL, L. A. Inativação de Escherichia coli e Clostridium perfringens em água empregando cloro e ácido peracético. In 22 Congresso da Asssociação Brasileira de Engenharia Sanitária e Ambiental, Joinville - SC, 2003. 22 Congresso da Asssociação Brasileira de Engenharia Sanitária e Ambiental.Rio de Janeiro - RJ : ABES, 2003.
  • SOUZA, Jeanette Béber de, SARTORI, Luci, e DANIEL, L. A. Influência da cor e da turbidez na desinfecção de águas de abastecimento utilizando-se cloro e radiação ultravioleta. In XXVII Congreso Interamericano de Ingenieria Sanitaria y Ambiental, Porto Alegre, 2000. Anais XXVII Congreso Interamericano de Ingenieria Sanitaria y Ambiental. : ABES, 2000.
All rights of the thesis/dissertation are from the authors
CeTI-SC/STI
Digital Library of Theses and Dissertations of USP. Copyright © 2001-2024. All rights reserved.