• JoomlaWorks Simple Image Rotator
  • JoomlaWorks Simple Image Rotator
  • JoomlaWorks Simple Image Rotator
  • JoomlaWorks Simple Image Rotator
  • JoomlaWorks Simple Image Rotator
  • JoomlaWorks Simple Image Rotator
  • JoomlaWorks Simple Image Rotator
  • JoomlaWorks Simple Image Rotator
  • JoomlaWorks Simple Image Rotator
  • JoomlaWorks Simple Image Rotator
 
  Bookmark and Share
 
 
Thèse de Doctorat
DOI
https://doi.org/10.11606/T.18.2022.tde-07122022-120937
Document
Auteur
Nom complet
Osmar Pereira da Silva Júnior
Unité de l'USP
Domain de Connaissance
Date de Soutenance
Editeur
São Carlos, 2022
Directeur
Jury
Daniel, Luiz Antonio (Président)
Boina, Welliton Leandro de Oliveira
Matsumoto, Tsunao
Silva, Gustavo Henrique Ribeiro da
Souza, Alexandre Teixeira de
Titre en portugais
Pós-tratamento físico-químico de efluente de lagoas de estabilização: potencialidade da utilização do lodo na construção civil
Mots-clés en portugais
Cloreto férrico
Lagoa de estabilização
Pós-tratamento
Tanino
Resumé en portugais
O presente estudo teve por objetivo avaliar o pós-tratamento físico-químico para o efluente da ETE Antas, no município de Dracena-SP. A ETE Antas é composta por um sistema de gradeamento, duas lagoas anaeróbias em série seguidas e uma lagoa facultativa, nesta sequência. A motivação do estudo foi produzir efluente com características que atendam o que está estabelecido no decreto do Estado de São Paulo No 8468 de 8 de setembro de 1976. Para tanto foram utilizados os coagulantes cloreto férrico e tanino. O estudo foi dividido em duas etapas. Na primeira etapa o objetivo foi determinar a melhor condição de coagulação, floculação e sedimentação, para a dosagem de coagulante que resultou em eficiência de remoção de DBO compatível com a qualidade necessária para atender a legislação, tanto para o cloreto férrico como para o tanino. Na segunda etapa foram estabelecidas as dosagens de 50 mg/L para o tanino e 75 mg/L para o cloreto férrico, definidas na primeira etapa. As análises realizadas na segunda etapa para caracterizar o efluente foram DBO, DQO, pH, turbidez, temperatura, fósforo, amônia, nitrato, nitrito, sólidos totais, sólidos suspensos totais e E. coli. O lodo gerado no pós-tratamento foi transformado em cinzas para realização das análises FRX e DRX para caracterização química e mineralógica. Essas análises foram realizadas para verificar a possibilidade de utilização das cinzas na construção civil. Os resultados da segunda etapa demonstraram que as dosagens de 50 mg/L do coagulante tanino e 75 mg/L do coagulante cloreto férrico utilizados no pós-tratamento físico-químico produziram efluentes com qualidade compatível à legislação ambiental do Estado de São Paulo. Os resultados das análises FRX e da DRX realizadas nas cinzas geradas a partir do lodo químico produzido nesta pesquisa, apresentaram características que permitiram concluir que este material tem potencial de uso na construção civil.
Titre en anglais
Physical and chemical post-treatment of effluent from stabilization ponds: potential use of sludge in civil construction
Mots-clés en anglais
Ferric chloride
Post treatment
Stabilization pond
Tannin
Resumé en anglais
The purpose of this study was to evaluate a physico-chemical post-treatment for the sewage from Sewage Treatment Station (STS) Antas in the city of Dracena-SP. The Sewage Treatment Station (STS) Antas is composed of a railing system followed by two serial anaerobic ponds followed by a facultative pond. The motivation of this study was to produce a sewage with characteristics which meet what is established in the legal regulation of the State of São Paulo Number 8468 of September 8th, 1976. For this the coagulants ferric chloride and tannin were used. The study was divided into two phases. In the first phase the purpose was to determine the best condition of coagulation, flocculation and sedimentation, for the coagulant dosage which resulted in efficiency in the removal of BOD compatible with the quantity needed to meet the legal regulation, as for ferric chloride as for tannin. In the second stage dosages were established of 50 mg/L for tannin and 75 mg/L for ferric chloride, defined in the first stage. The analyses performed in the second stage to characterize the effluent were BOD, COD, pH, turbidity, temperature, phosphorus, ammonia, nitrate, nitrite, total solids, total suspended solids and E. coli. The sludge generated in the post-treatment was turned into ashes for the performance of the analyses FRX and DRX for the chemical and mineralogical characterization. These analyses were performed to verify the possibility of using the ashes in the civil construction. The results in the second stage have shown that the dosages of 50 mg/L of the coagulant tannin and 75 mg/L of the coagulant ferric chloride used in the physico-chemical post-treatment produced sewages with quality to be framed in the legal regulation of the State of São Paulo. The results of the analyses FRX and DRX performed in the ashes generated from the chemical sludge produced in this research, have shown characteristics which made it possible to conclude that this material has potential for use in civil construction.
 
AVERTISSEMENT - Regarde ce document est soumise à votre acceptation des conditions d'utilisation suivantes:
Ce document est uniquement à des fins privées pour la recherche et l'enseignement. Reproduction à des fins commerciales est interdite. Cette droits couvrent l'ensemble des données sur ce document ainsi que son contenu. Toute utilisation ou de copie de ce document, en totalité ou en partie, doit inclure le nom de l'auteur.
Date de Publication
2022-12-09
 
AVERTISSEMENT: Apprenez ce que sont des œvres dérivées cliquant ici.
Tous droits de la thèse/dissertation appartiennent aux auteurs
CeTI-SC/STI
Bibliothèque Numérique de Thèses et Mémoires de l'USP. Copyright © 2001-2024. Tous droits réservés.