Master's Dissertation
DOI
https://doi.org/10.11606/D.18.2017.tde-03022017-123123
Document
Author
Full name
Carlos Magno de Sousa Vidal
Institute/School/College
Knowledge Area
Date of Defense
Published
São Carlos, 2001
Supervisor
Committee
Campos, José Roberto (President)
Hamada, Jorge
Reali, Marco Antonio Penalva
Title in Portuguese
Microfiltração tangencial como alternativa de pós-tratamento de efluente de reator anaeróbio de leito expandido alimentado com esgoto sanitário
Keywords in Portuguese
Coagulação e floculação
Esgoto sanitário
Microfiltração tangencial
Reatores anaeróbios
Reuso de águas
Abstract in Portuguese
A constante exploração dos recursos hídricos para os mais diferentes usos sem um planejamento adequado, tem levado ao comprometimento desses recursos, verificando-se cada vez mais aumento no número de pesquisas e investimentos, visando o estudo de alternativas que viabilizem o tratamento avançado de águas residuárias e sua reutilização. Entre essas alternativas, estão as técnicas de separação dos materiais contaminantes por membranas. Neste trabalho estudou-se a viabilidade da utilização da microfiltração tangencial como alternativa de pós-tratamento de efluente de Reator Anaeróbio de Leito Expandido alimentado com esgoto sanitário, analisando-se a influência da utilização de cloreto férrico como coagulante, bem como, membranas com diferentes tamanhos de poro (0,2 e 1,0 μm), no desempenho da microfiltração tangencial. Os ensaios no sistema de microfiltração tangencial foram realizados em batelada, com amostras de efluente do reator anaeróbio de leito expandido (RALEX). Verificou-se que para os ensaios realizados com a membrana de 0,2 μm, o aumento das dosagens de cloreto férrico, contribuiu para diminuição nos valores de luxo de permeado. Esta relação não ocorreu de forma direta com a membrana de 1,0 μm. Os processos de coagulação e floculação foram essenciais para ambas membranas no aumento na eficiência de remoção da demanda química total de oxigênio (mg/l), fosfato total (mg P/l) e turbidez, no entanto, em relação aos valores de fluxo do permeado,foi prejudicial, pois nos ensaios em que as amostras de efluente do RALEX não foram previamente coaguladas e floculadas, a permeabilidade das membranas foi bem maios. O sistema de microfiltração tangencial operando com a membrana de 0,2 μm apresentou melhor desempenho, com valores de fluxo do permeado, em geral superiores a 100 L/m2.h, eficiência de 100% na remoção de coliformes totais e fecais, e a dosagem de 40 mg/l de cloreto férrico, já foi suficiente para uma eficiência média de remoção de DQOt de 95%; P.PO4-3 (89,5%) e Turbidez (96,4%). Portanto, a microfiltração tangencial pode ser considerada uma alternativa eficaz como unidade de pós-tratamento de efluente de reator anaeróbio de leito expandido, produzindo efluente que atende os padrões de reuso na agricultura, para coliforme totais e fecais.
Title in English
Crossflow microfiltration as an alternative for advanced treatment of effluent of anaerobic reactor expanded bed feed with sewage
Keywords in English
Anaerobic reactor
Coagulation and flocculation
Crossflow microfiltration
Sewage
Water reuse
Abstract in English
The constant exploration of water resources for the most different uses, without an appropriate planning, has lead to the exhaustion of this resources. This scenery has showed the need of increasing researches and investments on alternative forms of wastewater treatment. This work studied the viability of using crossflow microfiltration as an alternative form of advanced treatment of effluents of Anaerobic Reactor Expanded Bed feed with sewage, examining the effect of the use of ferric chloride as coagulam, as well as of different pore size membranes (0,2 and 1,0 μm) on the performance of crossflow microfiltration. The experiments on crossflow microfiltration system were carried out in batch, using effluent samples of anaerobic reactor expanded bed. The results obtained with the 0,2 μm membrane showed that the increase of ferric chloride dosages contributed for the reduction on flux values. The 1,0 μm membrane did not presented this relation. The flocculation and coagulation processes were essentials for increasing the removal efficiency of Total Chemical Oxygen Demand, Total Phosphorus and Turbidity for both membranes, however, for the flux values the effect was harmful, because when the samples of the Anaerobic Reactor Expanded Bed were not previously coagulated and flocculated, the membranes penneability were higher. The Crossflow Microfiltration System, operating with the 0,2 μm membrane, presented better performance, with flux values generally superior than 100 L/m2.h, efficiency around 100% on the removal of Total and Fecal Coliforms. For this membrane (0,2 μm) the dosage of 40 mg/l of FeCl3 (first stage) was enough for an average of removal efficiency of Total Chemical Oxygen Demand (95%); Turbidity (96.4%); and P.PO4-3 (89,5%). Therefore, crossflow mocrofiltration can be considered an effective alternative for advanced treatment of effluents of Anaerobic Reactor Expanded Bed, producing a final effluent with large potentiality to be used in agriculture.
 
WARNING - Viewing this document is conditioned on your acceptance of the following terms of use:
This document is only for private use for research and teaching activities. Reproduction for commercial use is forbidden. This rights cover the whole data about this document as well as its contents. Any uses or copies of this document in whole or in part must include the author's name.
Publishing Date
2017-02-03
 
WARNING: Learn what derived works are clicking here.
All rights of the thesis/dissertation are from the authors
CeTI-SC/STI
Digital Library of Theses and Dissertations of USP. Copyright © 2001-2024. All rights reserved.