Mémoire de Maîtrise
DOI
https://doi.org/10.11606/D.18.2022.tde-20122022-124144
Document
Auteur
Nom complet
João Vitor Caldas Santos
Unité de l'USP
Domain de Connaissance
Date de Soutenance
Editeur
São Carlos, 2022
Directeur
Jury
Debs, Mounir Khalil El (Président)
Araujo, Daniel de Lima
Barros, Rodrigo
Titre en portugais
Análise numérica de cálice de fundação em bloco sobre duas estacas
Mots-clés en portugais
ABAQUS
análises numéricas
cálice de fundação
concreto pré-moldado
ligação pilar-fundação
Resumé en portugais
Dentro do contexto de ligação pilar-fundação em estruturas de concreto pré-moldado, este trabalho visa analisar o cálice de fundação externo, semiembutido e embutido em blocos sobre duas estacas submetidos à força vertical centrada. A pesquisa teve como objetivos específicos: investigar o comportamento da ligação entre o pilar e o bloco de fundação; avaliar a contribuição do tirante principal do bloco e da armadura vertical e horizontal do cálice; analisar a influência da interface nas situações de conformação lisa e com chave de cisalhamento; e comparar o desempenho estrutural dos blocos monolíticos e dos blocos com cálice. Para tanto, como metodologia, realizaram-se análises numéricas das variáveis de interesse da ligação de um modelo calibrado experimentalmente. As simulações numéricas foram realizadas no software ABAQUS 2020 por meio do Método dos Elementos Finitos. Observou-se que quanto maior o grau de embutimento do cálice, menor é a razão entre a força última do bloco com cálice e do bloco monolítico de referência, alcançado valores de 135%, 92% e 45% para a conformação lisa, e de 166%, 131% e 97% para a conformação com chave de cisalhamento. A transferências de esforços em cálices com chave de cisalhamento é mais eficiente quando comparada aos cálices lisos, conferindo aumento na força última em 23%, 46% e 106% para os graus de embutimento externo, semiembutido e embutido, respectivamente. O tirante principal do bloco é a armadura de maior influência na carga última. A armadura vertical e horizontal do cálice são pouco influentes na situação de carregamento centrado.
Titre en anglais
Numerical analysis of socket foundation in two-pile caps
Mots-clés en anglais
ABAQUS
column-foundation connection
numerical analyses
precast concrete
socket connection
Resumé en anglais
Within the context of column-foundation connection in precast concrete structures, this study aims to contribute to the analysis of external, partially embedded and embedded socket foundations in two-pile caps subjected to axial compressive loading. Therefore, it was evaluated: the behavior of the connection between column and pile cap; the contribution of pile cap's and socket foundation's main reinforcements; the influence of interface in situations of smooth conformation and with shear key; and the structural performance of monolithic two-pile caps and socket foundations. The methodology consists of developing on software ABAQUS 2020, by Finite Element Method, numerical analyses of the connection based on an experimentally calibrated model. It was observed that the greater degree of embedding socket, lower is the ratio between ultimate strength of pile cap with socket and monolithic reference pile cap, reaching values of 135%, 92% and 45% for smooth interface, and 166%, 131% and 97% for shear key interface. Transfers of efforts in sockets with shear key are more efficient when compared to smooth sockets, conferring an increase in ultimate strength by 23%, 46% and 106% for external, partially embedded and embedded socket, respectively. Pile cap's main reinforcement is the reinforcement with the greatest influence on the ultimate strength of the pile cap. Socket foundation's main reinforcements (vertical and horizontal) are little influential in the centered loading situation.
 
AVERTISSEMENT - Regarde ce document est soumise à votre acceptation des conditions d'utilisation suivantes:
Ce document est uniquement à des fins privées pour la recherche et l'enseignement. Reproduction à des fins commerciales est interdite. Cette droits couvrent l'ensemble des données sur ce document ainsi que son contenu. Toute utilisation ou de copie de ce document, en totalité ou en partie, doit inclure le nom de l'auteur.
Date de Publication
2023-01-04
 
AVERTISSEMENT: Apprenez ce que sont des œvres dérivées cliquant ici.
Tous droits de la thèse/dissertation appartiennent aux auteurs
CeTI-SC/STI
Bibliothèque Numérique de Thèses et Mémoires de l'USP. Copyright © 2001-2024. Tous droits réservés.