• JoomlaWorks Simple Image Rotator
  • JoomlaWorks Simple Image Rotator
  • JoomlaWorks Simple Image Rotator
  • JoomlaWorks Simple Image Rotator
  • JoomlaWorks Simple Image Rotator
  • JoomlaWorks Simple Image Rotator
  • JoomlaWorks Simple Image Rotator
  • JoomlaWorks Simple Image Rotator
  • JoomlaWorks Simple Image Rotator
  • JoomlaWorks Simple Image Rotator
 
  Bookmark and Share
 
 
Disertación de Maestría
DOI
https://doi.org/10.11606/D.18.2011.tde-10062011-153037
Documento
Autor
Nombre completo
Calil Zumerle Masioli
Instituto/Escuela/Facultad
Área de Conocimiento
Fecha de Defensa
Publicación
São Carlos, 2011
Director
Tribunal
Gonçalves, Roberto Martins (Presidente)
Fruchtengarten, Julio
Souza, Alex Sander Clemente de
Título en portugués
Análise teórica e experimental de ligações em aço entre pilar tubular de seção circular e viga de seção I
Palabras clave en portugués
Diafragmas externos
Estruturas tubulares
Ligação viga-coluna
Resumen en portugués
O atrativo estético proporcionado pela forma arredondada é o fator que na maioria das vezes determina a utilização de estruturas tubulares circulares. É crescente a concepção de pórticos formados por colunas tubulares e as tradicionais vigas de seção I. Esse tipo de ligação ainda é pouco estudado no Brasil, e esse trabalho busca avançar no entendimento do comportamento estrutural dessas ligações. Foram realizados estudos analíticos, numéricos e experimentais em quatro configurações de ligação, com diafragmas externos transversais, chapa de alma, soldas, parafusos e enrijecedor. Avaliou-se a relação M-'fi' (momento-rotação) das ligações estudadas e os parâmetros envolvidos como resistência, rigidez e ductilidade, evidenciando-se o modo de colapso das ligações. O estudo analítico foi desenvolvido baseado nas recomendações do Eurocode 3 (2005), com a utilização do Método das Componentes. A análise numérica, através do Método dos Elementos Finitos, foi realizada por meio dos programas computacionais TRUEGRID® e ANSYS®. Os modelos numéricos consideram as características mecânicas do aço, como plastificação, encruamento e não-linearidades geométricas e de contato. As formulações do Eurocode 3 (2005), adaptadas para a determinação da resistência das ligações viga-coluna, apresentaram resultados coerentes e a análise numérica foi representativa frente aos resultados experimentais. A utilização de diafragmas externos conectados à viga apresentou boa funcionalidade, ajudando na distribuição das tensões na região da ligação, melhorando o comportamento da coluna.
Título en inglés
Theoretical and experimental analysis of steel connections between circular hollow section column and I section beam
Palabras clave en inglés
Beam-to-column connection
External diaphragms
Tubular structures
Resumen en inglés
The aesthetic appeal provided by the round shape is the factor that mostly determines the use of circular tubular structures. There is an increasing conception of structures formed by hollow columns and traditional beams of section I. This type of connection hasn' t been sufficiently studied in Brazil, and this paper tries to advance the comprehension of the structural behavior of these connections. Analytical, numerical, and experimental study were performed in four connections configurations, with transverse external diaphragms, web plate, welds, bolts and stiffener. The relation M-'fi' (moment-rotation) of the studied connections and the parameters involved such as strength, stiffness and ductility were evaluated, evidencing the failure mode of connections. The analytical study was developed based on recommendations of Eurocode 3 (2005) using the Method of Components. The numerical analysis using the Finite Element Method was performed with the computer programs TRUEGRID® and ANSYS®. The numerical models consider the mechanical characteristics of steel, such as yielding and hardening, and also the geometric and contact nonlinearity. The formulations of Eurocode 3 (2005), adapted for determining the strength of beam-column connections, showed coherent results and the numerical analysis was representative compared to experimental results. The use of external diaphragm connected to the beam showed good functionality, helping in the distribution of stress in the region of connection, improving the behavior of the column.
 
ADVERTENCIA - La consulta de este documento queda condicionada a la aceptación de las siguientes condiciones de uso:
Este documento es únicamente para usos privados enmarcados en actividades de investigación y docencia. No se autoriza su reproducción con finalidades de lucro. Esta reserva de derechos afecta tanto los datos del documento como a sus contenidos. En la utilización o cita de partes del documento es obligado indicar el nombre de la persona autora.
Fecha de Publicación
2011-06-14
 
ADVERTENCIA: Aprenda que son los trabajos derivados haciendo clic aquí.
Todos los derechos de la tesis/disertación pertenecen a los autores
CeTI-SC/STI
Biblioteca Digital de Tesis y Disertaciones de la USP. Copyright © 2001-2024. Todos los derechos reservados.