Master's Dissertation
DOI
https://doi.org/10.11606/D.18.2003.tde-10062008-083850
Document
Author
Full name
Eduardo Gimenez de Souza
E-mail
Institute/School/College
Knowledge Area
Date of Defense
Published
São Carlos, 2003
Supervisor
Committee
Pinheiro, Libânio Miranda (President)
Aoki, Nelson
Corrêa, Márcio Roberto Silva
Title in Portuguese
Colapso de edifício por ruptura das estacas: estudo das causas e da recuperação
Keywords in Portuguese
Colapso estrutural
Recalques
Recuperação estrutural
Ruptura de estacas
Solo instável
Abstract in Portuguese
A maior parte dos acidentes em edifícios, causados por falhas de projeto ou de execução, ocorre na fase de construção. Além de causar prejuízos financeiros, eles colocam em risco a vida dos trabalhadores da obra. Porém, mais graves são os acidentes verificados após o término da construção. Além dos prejuízos serem muito maiores, eles podem envolver pessoas de todos os tipos, crianças, mulheres e idosos. São muitos os casos em que o colapso global do edifício decorre de problemas na fundação. Esse é o caso do edifício considerado neste trabalho, localizado no litoral norte do Estado de São Paulo. Trata-se de um edifício para veraneio, em alvenaria estrutural, com garagem no térreo e quatro andares de apartamentos, apoiado em estacas pré-moldadas, cravadas em solo instável. Pouco tempo após a conclusão e parcialmente ocupado, apresentou recalques e patologias significativas que exigiram providências, reforço de pilares de alvenaria inclusive. Antes que fossem detectadas as causas dos recalques, durante uma madrugada, o edifício desabou: em um lado do edifício, o primeiro pavimento encostou-se ao chão. Felizmente, era um dia-de-semana, fora da alta temporada, e não havia pessoas no seu interior. Também o vigia estava fora do edifício e nada sofreu, além de um grande susto. Os objetivos deste trabalho são descrever o problema ocorrido com esse edifício e analisar as causas e as providências possíveis para sua recuperação, já que os andares superiores praticamente nada sofreram. Serão apresentados os resultados de uma investigação no local e de uma análise para determinação dos esforços e das causas da ruptura das estacas, que provocaram o colapso do edifício. Ficou evidente que o aterro localizado sobre o pavimento térreo e o sistema de fundação do edifício não estavam adequados para o tipo de solo do terreno. Tais fatores tiveram papel fundamental para a ruptura do sistema. A importância de se conhecer minuciosamente essas causas transcende a presente obra, pois pelo mesmo motivo, outras construções podem apresentar danos semelhantes.
Title in English
Building collapse for piles rupture: study of the causes and recovery
Keywords in English
Piles rupture
Repress
Structural collapse
Structural recovery
Unstable soil
Abstract in English
Most of the buildings accidents, caused by project flaws or of execution, it happens in the construction phase. Besides causing financial damages, they put in risk the workers life. However, more serious accidents are verified after the end of the construction. Besides the damages are larger, they can involve all types of people, children, women and senior. In many cases the global building collapse elapses of foundation problems. That is the case of the building considered in this work, located in the north coast of São Paulo State. Treated of a building for summer vacation, in structural masonry, with garage in the earthy pavement and four floors of apartments, leaning in premolded piles, nailed in unstable soil. After the conclusion and partially in use, it presented repress and significant pathologies that demanded providences, column masonry reinforcement besides. Before detected the repress causes, during one dawn, the building tumbled: on a side of the building, the first pavement was leaned to the ground. Happily, it was a weekday, out of the high season, and there were not people inside. Also the watchmen was out of the building and nothing suffered, besides a great fright. The objectives of this healthy work are to describe the problem happened with that building, to analyze the causes and the possible providences for it recovery, since the superior walks practically nothing suffered. The results of a local investigation, an analysis for determination the efforts and the causes of the piles rupture will be presented, that provoked the building collapse. It was evident that the located embankment on the earthy pavement and the building foundation system, they were not adapted for the soil type of the land. Such factors had fundamental paper for the system rupture. The importance of knowing those causes thoroughly, transcends to present work, because for the same reason other constructions can present similar damages.
 
WARNING - Viewing this document is conditioned on your acceptance of the following terms of use:
This document is only for private use for research and teaching activities. Reproduction for commercial use is forbidden. This rights cover the whole data about this document as well as its contents. Any uses or copies of this document in whole or in part must include the author's name.