Mémoire de Maîtrise
DOI
https://doi.org/10.11606/D.18.2005.tde-10062005-150528
Document
Auteur
Nom complet
Geilson Márcio Albuquerque de Vasconcelos
Unité de l'USP
Domain de Connaissance
Date de Soutenance
Editeur
São Carlos, 2005
Directeur
Jury
Correa, Marcio Roberto Silva (Président)
Figueiredo Filho, Jasson Rodrigues de
Giongo, Jose Samuel
Titre en portugais
Verificação simultânea dos estados limites últimos e de serviço em análises não-lineares de peças de concreto armado submetidas à flexão pura
Mots-clés en portugais
análise não-linear física
estados limites
estruturas de concreto armado
segurança das estruturas
Resumé en portugais
Neste trabalho foram discutidos os aspectos de dimensionamento e verificação da segurança de elementos estruturais de concreto armado considerando a não-linearidade dos materiais. O estudo abordou uma nova proposta para a verificação simultânea dos estados limites últimos (ELU) e dos estados limites de serviço (ELS) para elementos de concreto armado submetidos à flexão, voltada especialmente para aplicações considerando a não-linearidade física utilizando o método dos elementos finitos. As propostas alternativas apresentadas na consideração de coeficientes minoradores das resistências dos materiais, trataram da utilização de valores médios para as relações tensão-deformação e para as resistências dos materiais; valores de referência que permitiram a composição de coeficientes globais de segurança, que independem da ruptura ser causada por esgotamento da capacidade resistente do concreto ou do aço e, finalmente, valores médios para as relações tensão-deformação no aço e no concreto, com limitação das resistências em seus valores de projeto. Foram analisadas seções transversais retangulares e do tipo T submetidas à flexão pura, com o uso das propostas alternativas. Foram, também, estudadas vigas isostáticas e hiperestáticas incluindo a verificação das reservas da capacidade resistente da estrutura, sendo que foi considerada a redistribuição dos esforços internos no caso hiperestático. As análises realizadas serviram de base para assumir-se que a terceira proposta anteriormente citada, é a mais adequada e a que atendeu, simultaneamente, às verificações dos ELU e ELS; o que a torna viável para aplicações práticas
Titre en anglais
Simultaneous verification of the ultimate limit states and of serviceability in nonlinear analysis of reinforced concrete beams subjected to pure bending
Mots-clés en anglais
limit states
physical non-linear analysis
reinforced concrete structures
safety of the structures
Resumé en anglais
The present work deals with dimensioning and verification of the safety conditions of reinforced concrete structural elements, taking into account the material non-linearity. It includes a new proposal for the simultaneous verification of the ultimate limit states (ULS) and the serviceability limit states (SLS) for reinforced concrete bending elements, enhancing finite element applications with physical non-linearities. The alternative proposals for the material safety factors include the use of mean values for the stress-strain relationships and the strength of materials; reference values that allow the composition of global safety coefficients that do not dependent on the type of failure, brittle in the concrete or ductile in the steel and, finally, means values for the concrete and steel stress-strain relationships, keeping the stresses always lower than the design strength values. Rectangular and T-type cross-sectional areas in pure bending were analyzed, using the alternative proposals. Statically determinate and hyperstatic beams were also studied to verify the safety conditions, including the redistribution of the internal forces in the hyperstatic cases. According to the analyses performed it is apparent that the third proposal is the most adequate and satisfies simultaneously the ULS and SLS verifications, being viable for practical applications
 
AVERTISSEMENT - Regarde ce document est soumise à votre acceptation des conditions d'utilisation suivantes:
Ce document est uniquement à des fins privées pour la recherche et l'enseignement. Reproduction à des fins commerciales est interdite. Cette droits couvrent l'ensemble des données sur ce document ainsi que son contenu. Toute utilisation ou de copie de ce document, en totalité ou en partie, doit inclure le nom de l'auteur.
Date de Publication
2005-06-30
 
AVERTISSEMENT: Apprenez ce que sont des œvres dérivées cliquant ici.
Tous droits de la thèse/dissertation appartiennent aux auteurs
CeTI-SC/STI
Bibliothèque Numérique de Thèses et Mémoires de l'USP. Copyright © 2001-2024. Tous droits réservés.