Disertación de Maestría
DOI
https://doi.org/10.11606/D.18.2004.tde-09112004-142924
Documento
Autor
Nombre completo
Walter Luiz Andrade de Oliveira
Instituto/Escuela/Facultad
Área de Conocimiento
Fecha de Defensa
Publicación
São Carlos, 2004
Director
Tribunal
Giongo, Jose Samuel (Presidente)
Pinheiro, Libanio Miranda
Pinto Junior, Newton de Oliveira
Título en portugués
Análise teórica e experimental de pilares de concreto armado sob ação de força centrada com resistência média à compressão do concreto de 40MPa
Palabras clave en portugués
análise experimental
concreto armado
ductilidade
pilares
Resumen en portugués
O objetivo primordial da pesquisa foi obter informações sobre o comportamento dúctil de pilares submetidos à compressão centrada moldados com concreto de resistência média à compressão de 40MPa. Os resultados obtidos experimentalmente foram confrontados com da análise numérica e se mostraram satisfatórios. O modelo adotado para análise teórica considerou as equações de equilíbrio que regem a segurança da seção transversal, e, o comportamento do pilar confinado. Para o desenvolvimento da parte experimental foram ensaiados 16 modelos de concreto armado: quatro com dimensões da seção transversal de 200mm x 200mm e altura de 1200mm e doze com dimensões da seção transversal de 150mm x 300mm e altura de 900mm, que apresentaram melhora no comportamento dúctil diretamente influenciada pelo aumento da taxa de armadura transversal. Foi verificado, também, o comportamento dúctil de pilares variando-se a resistência à compressão do concreto, a partir de dados experimentais de outros autores e deste trabalho. O comportamento de pilares se torna frágil com o aumento da resistência à compressão, assim foi gerada uma superfície que mostra o comportamento dúctil de pilares em função da taxa de armadura transversal e da resistência à compressão do concreto. Moldaram-se também, oito modelos não armados, para determinação do coeficiente K2, que leva em consideração a estimativa da resistência do concreto na estrutura, quando avaliada por meio de corpos-de-prova cilíndricos, e verificou-se que o valor desta variável diminui com o aumento da resistência à compressão do concreto, como sugere a norma Norueguesa. A utilização da variável K2 em função da resistência do concreto torna possível o dimensionamento de pilares de concreto de alta resistência considerando-se a seção íntegra ao invés da seção do núcleo
Título en inglés
Theoretical and experimental analysis of reinforced concrete columns under concentric compression with concrete strength of 40MPa
Palabras clave en inglés
columns
cuctile behavior
experimental analysis
reinforced concrete
Resumen en inglés
The main purpose of this research is to obtain information about the ductile behavior of concrete columns under concentric compression with concrete’s compressive strength of 40MPa. The experimental results were compared with those from a numerical analysis. The theoretical analysis was made using the equations that govern the safety of the cross section and the columns confinement behavior. For the development of the experimental program 16 specimens of reinforced concrete were tested: four with a 200mm x 200mm cross section and 1200mm height, and twelve with a 150mm x 300mm cross section and 900mm height, which presented improvement directly in the ductile behavior influenced by the increase in the rate of transverse reinforcement. It was also verified that the ductile behavior of columns with variations of the compressive strength of concrete, starting from third-party experimental data and from experimental results from this work, becomes fragile with the increase in concrete’s compressive strength. Thus, a surface was drawn showing the ductile behavior of concrete columns in function of the rate of traverse reinforcement and the concrete’s compressive strength. Eight specimens of plain concrete were also tested to determine the K2 coefficient that takes into account the estimate of the resistance for the concrete used in the column when appraised through cylindrical specimens. It was verified that the value for this variable decreases with the increase of the concrete’s compressive strength, as the Norwegian norm suggests. The use of the K2 coefficient in function of the concrete’s compressive strength turns possible calculate high-strength concrete columns being considered the complete section instead the nucleus section
 
ADVERTENCIA - La consulta de este documento queda condicionada a la aceptación de las siguientes condiciones de uso:
Este documento es únicamente para usos privados enmarcados en actividades de investigación y docencia. No se autoriza su reproducción con finalidades de lucro. Esta reserva de derechos afecta tanto los datos del documento como a sus contenidos. En la utilización o cita de partes del documento es obligado indicar el nombre de la persona autora.
Walter_Oliveira.pdf (8.33 Mbytes)
Fecha de Publicación
2004-11-10
 
ADVERTENCIA: Aprenda que son los trabajos derivados haciendo clic aquí.
Todos los derechos de la tesis/disertación pertenecen a los autores
CeTI-SC/STI
Biblioteca Digital de Tesis y Disertaciones de la USP. Copyright © 2001-2024. Todos los derechos reservados.