• JoomlaWorks Simple Image Rotator
  • JoomlaWorks Simple Image Rotator
  • JoomlaWorks Simple Image Rotator
  • JoomlaWorks Simple Image Rotator
  • JoomlaWorks Simple Image Rotator
  • JoomlaWorks Simple Image Rotator
  • JoomlaWorks Simple Image Rotator
  • JoomlaWorks Simple Image Rotator
  • JoomlaWorks Simple Image Rotator
  • JoomlaWorks Simple Image Rotator
 
  Bookmark and Share
 
 
Master's Dissertation
DOI
https://doi.org/10.11606/D.18.2017.tde-05042017-092151
Document
Author
Full name
Rubia Mara Bosse
Institute/School/College
Knowledge Area
Date of Defense
Published
São Carlos, 2017
Supervisor
Committee
Beck, André Teófilo (President)
Miguel, Leandro Fleck Fadel
Siqueira, Gustavo Henrique
Title in Portuguese
Desempenho de TMDS em edifícios submetidos a terremotos
Keywords in Portuguese
Análise dinâmica
Análise não linear geométrica
Controle de vibrações
Desempenho de TMDs
Elementos finitos
Processos estocásticos
Terremotos
TMD
Abstract in Portuguese
Técnicas e dispositivos para controlar vibrações em estruturas vêm sendo desenvolvidos e aprimorados para garantir segurança a estruturas sujeitas a carregamentos dinâmicos de grande magnitude, como o caso de tufões e terremotos. Neste sentido, o controle passivo de vibrações por meio de amortecedores de massa sintonizados, TMDs (Tuned Mass Dampers), é utilizado com muita eficiência no controle de vibrações induzidas por carregamentos externos de baixas frequências, como ventos. Porém, terremotos possuem um amplo espectro de frequências e por isso não há um acordo sobre a eficácia dos TMDs ao mitigar vibrações induzidas por sismos. Neste trabalho, estudou-se a sensibilidade dos parâmetros de frequência de sintonização e razão de massa dos TMDs que influenciam seu desempenho para controlar vibrações em edifícios sob carregamentos de terremotos. Para isso utilizou-se um modelo mais preciso em elementos finitos de pórtico plano não linear geométricos para obtenção do comportamento estrutural de um edifício de 20 pavimentos. Na simulação dos terremotos, desenvolveu-se um código para geração de processos estocásticos totalmente não estacionários e espectro-compatíveis, simulados para três diferentes configurações de solo. Descobriu-se que TMDs sintonizados para altas frequências têm melhor desempenho na minimização de deslocamentos e frequências de oscilação da estrutura. Esta conclusão é contrastante com o que se encontra na literatura, de que dispositivos sintonizados para a primeira frequências natural da estrutura são mais eficientes. Também se observou que TMDs com altas razões de massa (i.e. maiores que 10%) têm melhor performance. O melhor desempenho dos TMDs foi observado em dispositivos com altas razões de massa e moderadas a altas frequências de sintonização. Este trabalho mostra que o desempenho de sistemas de controle de vibrações passivos como TMDs depende do tipo de solo, do projeto dos dispositivos, da correta avaliação da resposta estrutural e da adequada representação do fenômeno que excita a estrutura.
Title in English
Performance of TMD-equipped buildings subjecto to earthquake loading
Keywords in English
Dynamical analysis
Earthquakes
Finite elements
Geometrical non linear analyses
Stochastic processes
TMD
TMD performance
Vibration control
Abstract in English
Techniques and devices for vibration control have been developed to ensure safety of structures subjected to relevant dinamic loads, as hurricanes and earthquakes. In this way, the passive control with TMDs (Tuned Mass Dampers) has been used with efficiency to suppress vibrations in structures subjected to low-frequency wind loads, for instance. However, for earthquakes that have a broad-banded frequency contend, there is no general agreement about the performance of TMDs. In this thesis, the sensitivity of TMD parameters that influence the performance of the devices is evaluated. An accutare non-linear plane frame finite element (FE) formulation is employed to estimate the structural behaviour of a 20-storey building under earthquake loads. For the representation of earthquakes, a code was developed for the generation of fully non-stationary spectrum-compatible stochastic process, for three types of soil. It was found that TMDs tuned to higher frequencies perform better at minimizing displacements and vibration frequencies, in contrast to what is commonly believed (e.g., that devices tuned to the building's fundamental natural frequency present ideal performance). Further, a compounding effect is also observed, with the best performance being obtained by TMDs of large mass tuned to moderate to high frequencies. The thesis shows that the performance of passive systems like TMDs depend on the type os soil, the design of the absorbers, the correct evaluation of structural behaviour and the right representation of the phenomenon that excitates the structure.
 
WARNING - Viewing this document is conditioned on your acceptance of the following terms of use:
This document is only for private use for research and teaching activities. Reproduction for commercial use is forbidden. This rights cover the whole data about this document as well as its contents. Any uses or copies of this document in whole or in part must include the author's name.
Publishing Date
2017-04-20
 
WARNING: Learn what derived works are clicking here.
All rights of the thesis/dissertation are from the authors
CeTI-SC/STI
Digital Library of Theses and Dissertations of USP. Copyright © 2001-2024. All rights reserved.