• JoomlaWorks Simple Image Rotator
  • JoomlaWorks Simple Image Rotator
  • JoomlaWorks Simple Image Rotator
  • JoomlaWorks Simple Image Rotator
  • JoomlaWorks Simple Image Rotator
  • JoomlaWorks Simple Image Rotator
  • JoomlaWorks Simple Image Rotator
  • JoomlaWorks Simple Image Rotator
  • JoomlaWorks Simple Image Rotator
  • JoomlaWorks Simple Image Rotator
 
  Bookmark and Share
 
 
Tesis Doctoral
DOI
https://doi.org/10.11606/T.18.2007.tde-27082007-213453
Documento
Autor
Nombre completo
Mauricio Cunha Escarpinati
Dirección Electrónica
Instituto/Escuela/Facultad
Área de Conocimiento
Fecha de Defensa
Publicación
São Carlos, 2007
Director
Tribunal
Schiabel, Homero (Presidente)
Mascarenhas, Yvone Maria
Moraes, José Carlos Teixeira de Barros
Netto, Thomaz Ghilardi
Traina, Agma Juci Machado
Título en portugués
Desenvolvimento de um sistema computacional para utilização em procedimentos de controle de qualidade em equipamentos mamográficos
Palabras clave en portugués
Controle de qualidade em imagens médicas
Digitalizadores
Filtro de Wiener
Mamografia
Processamento digital de imagens
Resumen en portugués
O presente trabalho consiste na elaboração de uma metodologia envolvendo técnicas computacionais para proporcionar informações provenientes de avaliação de qualidade de equipamentos mamográficos. A investigação conduzida levou em conta, além da necessária determinação de parâmetros operacionais - como tensão de pico (kVp), corrente de tubo, ponto focal, dose, tempo de exposição, camada semi-redutora -, a influência das características do digitalizador usado no processo de digitalização das imagens a ser avaliadas pelo esquema computacional, seja esse um sistema de aquisição digital direta ou indireta. Dessa forma, foi elaborado um protocolo de pré-processamento da imagem para compensar os efeitos do digitalizador antes da avaliação dos parâmetros de qualidade através dela. Simultaneamente ao desenvolvimento dos softwares necessários ao esquema, foi projetado e desenvolvido um simulador radiográfico para servir como instrumento para obtenção tanto das imagens a ser processadas pelo modelo computacional, como dos dados referentes aos parâmetros operacionais. O sistema foi desenvolvido tomando um mamógrafo calibrado e um instrumento de precisão como referências e testado em outros equipamentos mamográficos em operação em clínicas e hospitais. Os resultados foram consistentes com as análises comparativas utilizando as referências, o que podem fazer do sistema uma ferramenta útil na avaliação de qualidade em mamografia.
Título en inglés
Development of a computational system for quality control procedures on mammographic equipment
Palabras clave en inglés
Digital image processing
Digitizers
Mammography
Quality control on medical images
Wiener filter
Resumen en inglés
The present work consists on developing a computational methodology to provide information regarding to mammographic equipment quality evaluation. This investigation have taken into account, beyond the required operational parameters, such as kVp, electrical current, focal point, dose, exposition time, half-value layer, the influence of the film digitizer utilized for digitization process on the images to be evaluated by the computational scheme, either this a system of direct or indirect digital acquisition. Like so, it was elaborated an image pre-processing protocol to compensate the digitization effect on digital image, before the evaluation of quality control parameters through itself. Simultaneously to the development of the necessary software to the system, a radiographic phantom was developed to be used for achievement of either the images to be processed by the computational model, as operational parameters data. The system was developed taking calibrated mammographic equipment and a precise measurement instrument as references, besides, it was tested in other mammographic equipment in operation on clinics and hospitals. Results had shown consistent with the comparative analyses using those references, which can turn this system a useful tool for evaluation of mammography quality.
 
ADVERTENCIA - La consulta de este documento queda condicionada a la aceptación de las siguientes condiciones de uso:
Este documento es únicamente para usos privados enmarcados en actividades de investigación y docencia. No se autoriza su reproducción con finalidades de lucro. Esta reserva de derechos afecta tanto los datos del documento como a sus contenidos. En la utilización o cita de partes del documento es obligado indicar el nombre de la persona autora.
TDMauricio.pdf (8.28 Mbytes)
Fecha de Publicación
2007-09-04
 
ADVERTENCIA: Aprenda que son los trabajos derivados haciendo clic aquí.
Todos los derechos de la tesis/disertación pertenecen a los autores
CeTI-SC/STI
Biblioteca Digital de Tesis y Disertaciones de la USP. Copyright © 2001-2024. Todos los derechos reservados.