Thèse de Doctorat
DOI
https://doi.org/10.11606/T.18.2005.tde-19112007-144354
Document
Auteur
Nom complet
Marcelo Andrade da Costa Vieira
Adresse Mail
Unité de l'USP
Domain de Connaissance
Date de Soutenance
Editeur
São Carlos, 2005
Directeur
Jury
Schiabel, Homero (Président)
Costa, Paulo Roberto
Medeiros, Regina Bitelli
Oliveira, Maria Cristina Ferreira de
Silva, Ana Maria Marques da
Titre en portugais
Metodologia baseada nas funções de transferência para pré-processamento de imagens mamográficas digitais e sua aplicação em esquema computacional de auxílio ao diagnóstico
Mots-clés en portugais
Filtro de Wiener
Função de transferência óptica
Mamografia
Processamento de imagens
Resumé en portugais
Este trabalho tem por objetivo a investigação do comportamento de equipamentos de radiodiagnóstico em termos da qualidade da imagem produzida e a subseqüente aplicação desses resultados na otimização do desempenho de esquemas computacionais de auxílio ao diagnóstico, também conhecidos como esquemas CAD (do inglês, Computer-Aided Diagnosis). A principal meta consiste no desenvolvimento de técnicas de pré-processamento para imagens mamográficas digitalizadas que as realçasse de acordo com as características e limitações dos equipamentos utilizados na sua aquisição. A proposta está dividida em duas etapas. Na primeira, foram determinadas as características relativas tanto à resolução espacial como à resolução de contraste de diversos equipamentos mamográficos, avaliadas respectivamente pelas funções de transferência óptica e espectros de Wiener do ruído. Isto permitiu, numa segunda etapa, o desenvolvimento de um filtro digital específico para o pré-processamento de diferentes conjuntos de mamogramas digitais, separados de acordo com os equipamentos utilizados no processo de aquisição. Dessa forma, cada imagem mamográfica teve sua qualidade melhorada de acordo com as características do equipamento que a gerou, determinadas na primeira etapa. Essas imagens, depois de realçadas, foram utilizadas em um esquema CAD previamente desenvolvido, onde pôde ser observada uma melhora em até 12% no seu desempenho quando comparado aos resultados obtidos com imagens mamográficas não realçadas.
Titre en anglais
Transfer function based methodology to preprocessing digital mammographic image and its application on computer-aided diagnosis schemes
Mots-clés en anglais
Image processing
Mammography
Optical transfer function
Wiener filter
Resumé en anglais
The purpose of this work is to evaluate the quality of radiological equipment and their images in order to use these evaluations to improve the performance of a computer-aided diagnosis (CAD) scheme. The mean idea is about the development of image processing techniques to enhance digital mammograms according to the characteristics of the X-ray unit used for image acquisition. This work is basically divided in two parts. In the first one, it were determined the characteristics related to spatial and contrast resolution of several mammographic equipment, evaluated respectively from the optical transfer function and noise Wiener spectrum. This evaluation allowed, in a second part, the development of a preprocessing technique to enhance different set of digital mammographic images, gathered according to the equipment used on its acquisition process. Thus, each mammographic image had its quality improved in conformity with the characteristics of the equipment used on its acquisition, determined in the first part of this work. These images, after the enhancement process, were used on a previously developed CAD scheme. It was observed an improvement of 12% on the CAD performance using pre-processed mammograms compared to the results obtained when using non-enhanced mammographic images.
 
AVERTISSEMENT - Regarde ce document est soumise à votre acceptation des conditions d'utilisation suivantes:
Ce document est uniquement à des fins privées pour la recherche et l'enseignement. Reproduction à des fins commerciales est interdite. Cette droits couvrent l'ensemble des données sur ce document ainsi que son contenu. Toute utilisation ou de copie de ce document, en totalité ou en partie, doit inclure le nom de l'auteur.
Date de Publication
2007-11-28
 
AVERTISSEMENT: Apprenez ce que sont des œvres dérivées cliquant ici.
Tous droits de la thèse/dissertation appartiennent aux auteurs
CeTI-SC/STI
Bibliothèque Numérique de Thèses et Mémoires de l'USP. Copyright © 2001-2024. Tous droits réservés.