• JoomlaWorks Simple Image Rotator
  • JoomlaWorks Simple Image Rotator
  • JoomlaWorks Simple Image Rotator
  • JoomlaWorks Simple Image Rotator
  • JoomlaWorks Simple Image Rotator
  • JoomlaWorks Simple Image Rotator
  • JoomlaWorks Simple Image Rotator
  • JoomlaWorks Simple Image Rotator
  • JoomlaWorks Simple Image Rotator
  • JoomlaWorks Simple Image Rotator
 
  Bookmark and Share
 
 
Master's Dissertation
DOI
https://doi.org/10.11606/D.18.2018.tde-19012018-151156
Document
Author
Full name
Marcia Aparecida Silva
Institute/School/College
Knowledge Area
Date of Defense
Published
São Carlos, 1997
Supervisor
Committee
Schiabel, Homero (President)
Medeiros, Regina Bitelli
Mühlen, Sérgio Santos
Title in Portuguese
Um método de avaliação da nitidez de imagens radiográficas por simulação computacional do sistema de registro
Keywords in Portuguese
Combinação écran-filme
Imagem mamográfica
Imagem radiográfica
Mamografia
Sistema écran-filme
Abstract in Portuguese
A presente pesquisa objetiva essencialmente o desenvolvimento de um método para prever a influência do sistema de registro sobre a nitidez de imagens radiográficas por simulação computacional, procurando apresentar previamente na tela do microcomputador a imagem a ser obtida para cada tipo de filme ou combinação écran-filme usada durante a exposição. O método proposto tem condições de proporcionar uma ampla avaliação da qualidade de sistemas radiográficos em razão da quantidade de fatores que permite combinar na investigação, como ponto focal, efeito ''Heel", magnificação, característica de campo e características de filmes e écrans. A simulação investiga a influência que um tipo de filme ou combinação écran-filme exerce sobre a nitidez da imagem, possibilitando conhecer previamente a imagem final a ser obtida com diferentes equipamentos e sistemas de registro.
Title in English
not available
Keywords in English
not available
Abstract in English
The purpose of this work is the development of a method designed to predict the influence of the record system on radiographic images sharpness by computer simulation. The aim of this research is to show on the monitor the image to be obtained with any type of film or screen-film combination used during the x-ray exposure. The method provides a wide quality evaluation of radiographic systems because of the number of parameters which can be combined in the investigation, such as focal spot, Heel effect, magnification, field characteristics of films and screen-film combinations. The simulation investigates therefore the influence of a particular type of film or screen-film combination on the image sharpness, and allows to know previously the output image to be obtained with different x-ray equipments and record systems.
 
WARNING - Viewing this document is conditioned on your acceptance of the following terms of use:
This document is only for private use for research and teaching activities. Reproduction for commercial use is forbidden. This rights cover the whole data about this document as well as its contents. Any uses or copies of this document in whole or in part must include the author's name.
Publishing Date
2018-01-23
 
WARNING: Learn what derived works are clicking here.
All rights of the thesis/dissertation are from the authors
CeTI-SC/STI
Digital Library of Theses and Dissertations of USP. Copyright © 2001-2024. All rights reserved.