Disertación de Maestría
DOI
https://doi.org/10.11606/D.17.2020.tde-24082020-094901
Documento
Autor
Nombre completo
Julio Cesar Nather Junior
Dirección Electrónica
Instituto/Escuela/Facultad
Área de Conocimiento
Fecha de Defensa
Publicación
Ribeirão Preto, 2019
Director
Tribunal
Salmon, Carlos Ernesto Garrido (Presidente)
Araújo Junior, David
Marques, Vanessa Daccach
Título en portugués
Detecção automática de lesões novas em exames consecutivos de pacientes com esclerose múltipla
Palabras clave en portugués
Detecção automática de lesões
Esclerose múltipla
Inteligência artificial
Segmentação automática
Volumetria
Resumen en portugués
Embasamento: A Esclerose Múltipla (EM) é uma doença desmielinizante inflamatória restrita ao sistema nervoso central, caracterizada pela ocorrência de inflamação focal com distribuição perivenular. Os critérios diagnósticos da doença foram revisados em 2017, sendo conhecidos como critérios de McDonald e se baseiam nos princípios de dissociação temporal e espacial das lesões. Apesar de ser conhecido que a doença acomete virtualmente qualquer porção do SNC, sendo predominante na substância branca (SB), porém, não exclusiva, envolvendo também córtex e substância cinzenta (SC) profunda. A identificação de recorrência da doença se baseia na identificação de focos macroscópicos de desmielinização, conhecidos como placas. In vivo, o diagnóstico das placas depende da sua identificação em exames de imagem ressonância magnética (MRI). Os pacientes com EM são submetidos a exames de MRI do encéfalo com o intuito de se identificar lesões novas ou aumento do volume total de lesões. A lesão aparece no exame de MRI como uma imagem de hiperintensidade de sinal em sequências T2, que pode ser isolada, medindo mais que 3 a 5 mm, ovaladas, com realce após administração de contraste paramagnético intravenoso na fase aguda. Cronicamente as placas se tornam menos delimitáveis, coalescentes, formando aglomerados dismórficos com predomínio no corpo caloso e região de SB periventricular. A detecção de novas lesões entre dois exames de MRI é critério para a definição de estabilidade ou progressão de doença, bem como o sucesso ou fracasso terapêutico. Em pacientes com alta carga lesional, a detecção de uma nova e pequena lesão não é tarefa trivial para o médico radiologista. Objetivo: Para aumentar a sensibilidade e especificidade do exame é a proposta deste trabalho o desenvolvimento de um algoritmo computacional para volumetria de lesões e comparação entre diferentes tempos de estudo a fim de identificar lesões novas. Casuística e Método: Foram analisadas retrospectivamente as imagens de 99 pacientes com diagnóstico confirmado de Esclerose Múltipla e acompanhados clinicamente no HCFMRP-USP no período de 2013 a 2020 com imagens adquiridas um equipamento de 3T (Philips, Achieva). A imagem volumétrica FLAIR de dois exames consecutivos foram segmentadas e corregistradas. Uma ferramenta para detecção de novas lesões foi implementada, comparando exames prévios e recentes por software de detecção automática de lesões. Resultados: Foi observada uma sensibilidade de 95% e especificidade de 31%. Somente houve um falso negativo entre os 99 exames avaliados. Conclusão: o algoritmo desenvolvido foi considerado efetivo, com alta sensibilidade e funcionando de forma totalmente automática. A prática diária demonstrou que houve um auxílio real na rotina de avaliação dos exames, aumentando a rapidez e confiabilidade da avaliação. A baixa especificidade não compromete a eficiência, sendo os falsos positivos rapidamente descartados pelo médico radiologista.
Título en inglés
Automatic detection of new injuries in consecutive examinations of patients with multiple sclerosis
Palabras clave en inglés
Artificial intelligence
Automatic lesion detection
Automatic segmentation
Multiple sclerosis
Volumetry
Resumen en inglés
Background: Multiple Sclerosis (MS) is an inflammatory demyelinating disease restricted to the central nervous system, characterized by the occurrence of focal inflammation with perivenular distribution. The diagnostic criteria for the disease were revised in 2017, known as McDonald's criteria and are based on the principles of temporal and spatial dissociation of injuries. Although it is known that the disease affects virtually any portion of the CNS, being predominant in white matter (SB), however, not exclusive, also involving cortex and deep gray matter (SC). The identification of disease recurrence is based on the identification of macroscopic foci of demyelination, known as plaques. In vivo, the diagnosis of plaques depends on their identification in magnetic resonance imaging (MRI) exams. Patients with MS are submitted to brain MRI exams in order to identify new lesions or increase the total lesion volume. The lesion appears on the MRI exam as an image of signal hyperintensity in T2 sequences, which can be isolated, measuring more than 3 to 5 mm, oval, with enhancement after intravenous paramagnetic contrast in the acute phase. Chronically, the plaques become less delimitable, coalescent, forming dysmorphic clusters with predominance in the corpus callosum and periventricular SB region. The detection of new lesions between two MRI exams is a criterion for defining disease stability or progression, as well as therapeutic success or failure. In patients with a high lesion load, the detection of a new and small lesion is not a trivial task for the radiologist. Objective: To increase the sensitivity and specificity of the exam, the purpose of this work is to develop a computational algorithm for lesion volumetry and to compare different study times in order to identify new lesions. Casuistic and Method: The images of 99 patients with confirmed diagnosis of Multiple Sclerosis were retrospectively analyzed and followed up clinically at HCFMRP-USP in the period from 2013 to 2020 with images acquired from a 3T equipment (Philips, Achieva). The volumetric FLAIR image of two consecutive exams was segmented and registered. A tool for detecting new injuries was implemented, comparing previous and recent exams using automatic injury detection software. Results: A sensitivity of 95% and specificity of 31% were observed. There was only one false negative among the 99 tests evaluated. Conclusion: the developed algorithm was considered effective, with high sensitivity and working in a fully automatic way. Daily practice demonstrated that there was a real help in the routine of exam assessment, increasing the speed and reliability of the assessment. Low specificity does not compromise efficiency, and false positives are quickly discarded by the radiologist.
 
ADVERTENCIA - La consulta de este documento queda condicionada a la aceptación de las siguientes condiciones de uso:
Este documento es únicamente para usos privados enmarcados en actividades de investigación y docencia. No se autoriza su reproducción con finalidades de lucro. Esta reserva de derechos afecta tanto los datos del documento como a sus contenidos. En la utilización o cita de partes del documento es obligado indicar el nombre de la persona autora.
Fecha de Publicación
2020-10-21
 
ADVERTENCIA: Aprenda que son los trabajos derivados haciendo clic aquí.
Todos los derechos de la tesis/disertación pertenecen a los autores
CeTI-SC/STI
Biblioteca Digital de Tesis y Disertaciones de la USP. Copyright © 2001-2024. Todos los derechos reservados.