• JoomlaWorks Simple Image Rotator
  • JoomlaWorks Simple Image Rotator
  • JoomlaWorks Simple Image Rotator
  • JoomlaWorks Simple Image Rotator
  • JoomlaWorks Simple Image Rotator
  • JoomlaWorks Simple Image Rotator
  • JoomlaWorks Simple Image Rotator
  • JoomlaWorks Simple Image Rotator
  • JoomlaWorks Simple Image Rotator
  • JoomlaWorks Simple Image Rotator
 
  Bookmark and Share
 
 
Disertación de Maestría
DOI
https://doi.org/10.11606/D.17.2020.tde-23082020-151418
Documento
Autor
Nombre completo
Thaisa Gvozdenovic Medina Bricio
Dirección Electrónica
Instituto/Escuela/Facultad
Área de Conocimiento
Fecha de Defensa
Publicación
Ribeirão Preto, 2020
Director
Tribunal
Muglia, Valdair Francisco (Presidente)
Macedo, Tulio Augusto Alves
Tucci Junior, Silvio
Título en portugués
Validação do escore VI-RADS para estadiamento das neoplasias vesicais
Palabras clave en portugués
Camada muscular
Neoplasia vesical
Ressonância magnética
VI-RADS
Resumen en portugués
Objetivo: Proceder a uma validação externa da normativa VI-RADS, analisando a acurácia diagnóstica, comparando os escores das imagens em T2, difusão, contraste dinâmico (DCE) e VI-RADS final, além de verificar a concordância interobservador entre radiologistas de diversos níveis de experiência. Materiais e métodos: Foram avaliados estudos de ressonância magnética de pacientes com a suspeita clínica de neoplasia vesical entre junho de 2017 e janeiro de 2020 anteriormente a ressecção transuretral (RTU) retrospectivamente em um único centro. Todas as RM foram analisadas por três radiologistas com níveis de experiência diferentes, que atribuíram um escore VI-RADS para cada lesão em cada sequencia de RM. Foram calculados então a partir dessas análises sensibilidade, especificidade, valor preditivo positivo (VPP), valor preditivo negativo (VPN), acurácia diagnóstica e concordância interobservador. Resultados: Analisando o escore VI-RADS final atribuído por cada observador, a sensibilidade, foi de 94,1%, com intervalo de confiança de 95%, variando de 71,3 a 99,8% para o observador 1, 76,5% (50,1-93,2%) para o observador 2 e 94,1% (71,3-99,8%) para o observador 3, com uma especificidade, respectivamente, de 54,5% (32,2-75,6), 81,8% (59,7-94,8%) e 77,3% (54,6-92,1%). O VPP foi de 61,5% (49,9 - 72,0%) para o observador 1, 76,5% (56,3-89,1%) para as análises do observador 2 e 76,2% (59,5- 87,5%) para o observador 3, com um VPN de 92,3% (63,3-98,8%) para o observador 1, 81,8% (65,1 - 91,6%) para o observador 2 e 94,4% (71,5-99,1%) para o observador 3. A acurácia obtida foi de 71,8% (55,1-81,0%) para o observador 1, 79,5% (63,5- 90,7%) para o observador 2 e 84,6% (69,5-94,1%) para o observador 3. Conclusão: A normativa VI-RADS demonstrou boa acurácia para avaliação da invasão da camada muscular vesical nos tumores de bexiga, concordante com a literatura disponível. O nível de reprodutibilidade foi bom, apesar de discretamente inferior aos mencionados na literatura.
Título en inglés
Validations of the VI-RADS scoring system for vesical neoplasm
Palabras clave en inglés
MRI
Muscle layer
Vesical neoplasm
VI-RADS
Resumen en inglés
Objectives: The main purpose of this study was to validate the VI-RADS scoring system for vesical neoplasms, using accuracy as a marker by comparing the categories given by each radiologist for each MRI sequencies (T2, DWI, DCE and final VI-RADS escore) with the pathological findings. Besides the main goal, we assessed the interobserver agreement in different levels of experience. Materials and Methods: This was a retrospective study, in a single center where the MRI studies between june 2017 and february 2020 of patients with the clinical suspition of vesical neoplasm were analysed before they undergo any kind of intervention. Each MRI study was analysed by three different radiologists with different levels of experience, who categorized the lesions as set in the VI-RADS coring system in each MRI sequence. After that sensitivity, specificity, positive predictive value, negative predictive value, accuracy and interobserver agreement were then calculated. Results: By analysing the scores given by each radiologist for each vesical tumor we obtained sensitivy of 94,1%, with confidence interval of 95%, varying from 71,3 to 99,8% for observer 1, 76,5% (50,1-93,2%) for observer 2 and 94,1% (71,3-99,8%) for oberverser 3. The specificity was, respectively, 54,5% (32,2-75,6), 81,8% (59,7-94,8%) and 77,3% (54,6-92,1%). THE PPV was 61,5% (49,9 - 72,0%) for observer 1, 76,5% (56,3-89,1%) for observer 2 and 76,2% (59,5-87,5%) for observer 3, with a NPV 92,3% (63,3-98,8%) for observer 1, 81,8% (65,1 - 91,6%) for observer 2 and 94,4% (71,5-99,1%) for observer 3. Accuracy was 71,8% (55,1- 81,0%) for observer 1, 79,5% (63,5-90,7%) for observer 2 and 84,6% (69,5-94,1%) for observer 3. Conclusion: The scoring system VI-RADS is accurate in demonstrating muscle invasive bladder neoplasm, in agreement with the recent literature. The level of reproducibility as good, but slightly inferior than mencioned in literature.
 
ADVERTENCIA - La consulta de este documento queda condicionada a la aceptación de las siguientes condiciones de uso:
Este documento es únicamente para usos privados enmarcados en actividades de investigación y docencia. No se autoriza su reproducción con finalidades de lucro. Esta reserva de derechos afecta tanto los datos del documento como a sus contenidos. En la utilización o cita de partes del documento es obligado indicar el nombre de la persona autora.
Fecha de Publicación
2020-10-19
 
ADVERTENCIA: Aprenda que son los trabajos derivados haciendo clic aquí.
Todos los derechos de la tesis/disertación pertenecen a los autores
CeTI-SC/STI
Biblioteca Digital de Tesis y Disertaciones de la USP. Copyright © 2001-2024. Todos los derechos reservados.