• JoomlaWorks Simple Image Rotator
  • JoomlaWorks Simple Image Rotator
  • JoomlaWorks Simple Image Rotator
  • JoomlaWorks Simple Image Rotator
  • JoomlaWorks Simple Image Rotator
  • JoomlaWorks Simple Image Rotator
  • JoomlaWorks Simple Image Rotator
  • JoomlaWorks Simple Image Rotator
  • JoomlaWorks Simple Image Rotator
  • JoomlaWorks Simple Image Rotator
 
  Bookmark and Share
 
 
Disertación de Maestría
DOI
https://doi.org/10.11606/D.17.2018.tde-10042018-165710
Documento
Autor
Nombre completo
Fernando Carrasco Ferreira Dionisio
Dirección Electrónica
Instituto/Escuela/Facultad
Área de Conocimiento
Fecha de Defensa
Publicación
Ribeirão Preto, 2017
Director
Tribunal
Barbosa, Marcello Henrique Nogueira (Presidente)
Pagnano, Rodrigo Gonçalves
Marques, Paulo Mazzoncini de Azevedo
Scrideli, Carlos Alberto
 
Título en portugués
Avaliação da reprodutibilidade intra e interobservador da segmentação manual de sarcomas ósseos em imagens de ressonância magnética
Palabras clave en portugués
Osteossarcoma
Ressonância Magnética
Sarcoma de Ewing
Segmentação
Resumen en portugués
Os sarcomas ósseos representam uma proporção significativa de tumores na faixa etária pediátrica, ainda apresentando um quadro desafiador devido a sua significativa taxa de morbimortalidade. Pesquisas para o desenvolvimento de novas modalidades terapêuticas e para o desenvolvimento de métodos que identifiquem características da doença que possam permitir melhor estratificação dos pacientes através de dados clinicamente relevantes para individualizar as condutas clínicas são necessárias. Dentro deste contexto surge o conceito de radiômica, que visa extrair dados clinicamente relevantes a partir de imagens médicas. Entretanto, para colocar a radiômica em prática, é necessário selecionar, nas imagens médicas, as áreas de interesse referentes às patologias estudadas, e este processo se denomina segmentação. O objetivo primário deste estudo foi avaliar a reprodutibilidade intra e inter-observador da segmentação manual de sarcomas ósseos em imagens de ressonância magnética (RM). Como objetivo secundário, foi avaliada a capacidade da segmentação semiautomática em reduzir o tempo necessário para segmentação, mantendo similaridade com a segmentação manual. O estudo foi realizado de forma retrospectiva com inclusão de pacientes com diagnóstico de osteossarcoma ou sarcoma de Ewing confirmado por estudo histopatológico e que tivessem imagens de RM realizadas no Hospital Universitário de nossa Instituição realizadas previamente a qualquer intervenção terapêutica. Três médicos radiologistas, de forma independente e às cegas em relação as demais segmentações e em relação ao resultado histopatológico, realizaram a segmentação manual dos contornos destes tumores utilizando o software 3DSlicer, permitindo que fosse realizada avaliação da reprodutibilidade interobservador. Um dos radiologistas realizou uma segunda segmentação manual dos mesmos casos, possibilitando a avaliação da reprodutibilidade intraobservador, e, ainda, uma terceira segmentação foi realizada, utilizando metodologia semiautomática, disponível no software mencionado. Para a análise estatística, foi utilizado o coeficiente de similaridade de Dice (DICE), a distância Hausdorff (DH), comparações de volumes e análises dos intervalos de tempo necessários para realização das segmentações. Os parâmetros avaliados demonstraram haver boa reprodutibilidade intraobservador, com DICE variando entre 0,83 a 0,97; e distância Hausdorff variando entre 3,37 a 28,73 mm. Também foi demonstrada boa reprodutibilidade interobservador com DICE variando entre 0,73 a 0,97; e distância Hausdorff variando entre 3,93 a 33,40 mm. A segmentação semiautomática demonstrou boa similaridade em relação à segmentação manual (DICE variando entre 0,71 a 0,96 e DH variando entre 5,38 a 31,54 mm), havendo redução significativa do tempo necessário para segmentação. Entre todas as situações comparadas, os volumes não apresentaram diferenças estatisticamente significativas (p-valor>0,05).
 
Título en inglés
Evaluation of intra- and inter-observer manual segmentation reproducibility in magnetic images of bone sarcomas
Palabras clave en inglés
Ewing sarcoma
Manual segmentation
Osteosarcoma
Semiautomatic segmentation
Resumen en inglés
Bone sarcomas represent a significant proportion of tumors in the pediatric age group and they still are a challenge due to their significant morbidity and mortality rates. Reseaches are important for the development of new therapeutic modalities and for the development of methods that identify features that allow better stratification of the patients with theses diseases for individualization of their treatments. In this context emerges the concept of radiomics, which is the process of extraction of clinically relevant data from medical images. It is important to segment the areas of interest im medical images for the pratice of this process. The primary objective of this study was to evaluate the intra- and interobserver reproducibility of manual segmentation of bone sarcomas on magnetic resonance imaging (MRI). As a secondary objective, it was evaluated if the semiautomatic segmentation could be similar to manual segmentation and if the semiautomatic method could reduce the time required for segmentation. The study was performed retrospectively with the inclusion of patients with osteosarcoma or Ewing sarcoma confirmed by histopathological study and who had MRI performed at the University Hospital of our Institution prior to any therapeutic intervention. Three radiologists, independently and blindly in relation to the other segmentations and in relation to the histopathological results, performed the manual segmentation of the contours of these tumors using 3DSlicer software, allowing an interobserver reproducibility evaluation. One of the radiologists performed a second manual segmentation of the same cases, allowing the evaluation of intraobserver reproducibility. A third segmentation was performed, using semi-automatic methodology, available in the mentioned software. For the statistical analysis, Dice similarity coefficient (DICE), Hausdorff distance (DH), comparisons between volumes and time intervals for segmentations were used. The parameters evaluated demonstrated a good intraobserver reproducibility, with DICE ranging from 0.83 to 0.97 and Hausdorff distance ranging from 3.37 to 28.73 mm. Good interobserver reproducibility was also demonstrated with DICE ranging from 0.73 to 0.97 and Hausdorff distance ranging from 3.93 to 33.40 mm. Semiautomatic segmentation demonstrated good similarity to manual segmentation (DICE ranging from 0.71 to 0.96 and HD ranging from 5.38 to 31.54mm), and there was significant reduction in the time required for segmentation. Among all the situations compared, the volumes did not present significant statistical differences (p-value> 0.05).
 
ADVERTENCIA - La consulta de este documento queda condicionada a la aceptación de las siguientes condiciones de uso:
Este documento es únicamente para usos privados enmarcados en actividades de investigación y docencia. No se autoriza su reproducción con finalidades de lucro. Esta reserva de derechos afecta tanto los datos del documento como a sus contenidos. En la utilización o cita de partes del documento es obligado indicar el nombre de la persona autora.
Fecha de Publicación
2018-07-16
 
ADVERTENCIA: Aprenda que son los trabajos derivados haciendo clic aquí.
Todos los derechos de la tesis/disertación pertenecen a los autores.
CeTI-SC/STI
© 2001-2024. Biblioteca Digital de Tesis y Disertaciones de la USP.