• JoomlaWorks Simple Image Rotator
  • JoomlaWorks Simple Image Rotator
  • JoomlaWorks Simple Image Rotator
  • JoomlaWorks Simple Image Rotator
  • JoomlaWorks Simple Image Rotator
  • JoomlaWorks Simple Image Rotator
  • JoomlaWorks Simple Image Rotator
  • JoomlaWorks Simple Image Rotator
  • JoomlaWorks Simple Image Rotator
  • JoomlaWorks Simple Image Rotator
 
  Bookmark and Share
 
 
Master's Dissertation
DOI
https://doi.org/10.11606/D.17.2018.tde-10042018-165710
Document
Author
Full name
Fernando Carrasco Ferreira Dionisio
E-mail
Institute/School/College
Knowledge Area
Date of Defense
Published
Ribeirão Preto, 2017
Supervisor
Committee
Barbosa, Marcello Henrique Nogueira (President)
Pagnano, Rodrigo Gonçalves
Marques, Paulo Mazzoncini de Azevedo
Scrideli, Carlos Alberto
Title in Portuguese
Avaliação da reprodutibilidade intra e interobservador da segmentação manual de sarcomas ósseos em imagens de ressonância magnética
Keywords in Portuguese
Osteossarcoma
Ressonância Magnética
Sarcoma de Ewing
Segmentação
Abstract in Portuguese
Os sarcomas ósseos representam uma proporção significativa de tumores na faixa etária pediátrica, ainda apresentando um quadro desafiador devido a sua significativa taxa de morbimortalidade. Pesquisas para o desenvolvimento de novas modalidades terapêuticas e para o desenvolvimento de métodos que identifiquem características da doença que possam permitir melhor estratificação dos pacientes através de dados clinicamente relevantes para individualizar as condutas clínicas são necessárias. Dentro deste contexto surge o conceito de radiômica, que visa extrair dados clinicamente relevantes a partir de imagens médicas. Entretanto, para colocar a radiômica em prática, é necessário selecionar, nas imagens médicas, as áreas de interesse referentes às patologias estudadas, e este processo se denomina segmentação. O objetivo primário deste estudo foi avaliar a reprodutibilidade intra e inter-observador da segmentação manual de sarcomas ósseos em imagens de ressonância magnética (RM). Como objetivo secundário, foi avaliada a capacidade da segmentação semiautomática em reduzir o tempo necessário para segmentação, mantendo similaridade com a segmentação manual. O estudo foi realizado de forma retrospectiva com inclusão de pacientes com diagnóstico de osteossarcoma ou sarcoma de Ewing confirmado por estudo histopatológico e que tivessem imagens de RM realizadas no Hospital Universitário de nossa Instituição realizadas previamente a qualquer intervenção terapêutica. Três médicos radiologistas, de forma independente e às cegas em relação as demais segmentações e em relação ao resultado histopatológico, realizaram a segmentação manual dos contornos destes tumores utilizando o software 3DSlicer, permitindo que fosse realizada avaliação da reprodutibilidade interobservador. Um dos radiologistas realizou uma segunda segmentação manual dos mesmos casos, possibilitando a avaliação da reprodutibilidade intraobservador, e, ainda, uma terceira segmentação foi realizada, utilizando metodologia semiautomática, disponível no software mencionado. Para a análise estatística, foi utilizado o coeficiente de similaridade de Dice (DICE), a distância Hausdorff (DH), comparações de volumes e análises dos intervalos de tempo necessários para realização das segmentações. Os parâmetros avaliados demonstraram haver boa reprodutibilidade intraobservador, com DICE variando entre 0,83 a 0,97; e distância Hausdorff variando entre 3,37 a 28,73 mm. Também foi demonstrada boa reprodutibilidade interobservador com DICE variando entre 0,73 a 0,97; e distância Hausdorff variando entre 3,93 a 33,40 mm. A segmentação semiautomática demonstrou boa similaridade em relação à segmentação manual (DICE variando entre 0,71 a 0,96 e DH variando entre 5,38 a 31,54 mm), havendo redução significativa do tempo necessário para segmentação. Entre todas as situações comparadas, os volumes não apresentaram diferenças estatisticamente significativas (p-valor>0,05).
Title in English
Evaluation of intra- and inter-observer manual segmentation reproducibility in magnetic images of bone sarcomas
Keywords in English
Ewing sarcoma
Manual segmentation
Osteosarcoma
Semiautomatic segmentation
Abstract in English
Bone sarcomas represent a significant proportion of tumors in the pediatric age group and they still are a challenge due to their significant morbidity and mortality rates. Reseaches are important for the development of new therapeutic modalities and for the development of methods that identify features that allow better stratification of the patients with theses diseases for individualization of their treatments. In this context emerges the concept of radiomics, which is the process of extraction of clinically relevant data from medical images. It is important to segment the areas of interest im medical images for the pratice of this process. The primary objective of this study was to evaluate the intra- and interobserver reproducibility of manual segmentation of bone sarcomas on magnetic resonance imaging (MRI). As a secondary objective, it was evaluated if the semiautomatic segmentation could be similar to manual segmentation and if the semiautomatic method could reduce the time required for segmentation. The study was performed retrospectively with the inclusion of patients with osteosarcoma or Ewing sarcoma confirmed by histopathological study and who had MRI performed at the University Hospital of our Institution prior to any therapeutic intervention. Three radiologists, independently and blindly in relation to the other segmentations and in relation to the histopathological results, performed the manual segmentation of the contours of these tumors using 3DSlicer software, allowing an interobserver reproducibility evaluation. One of the radiologists performed a second manual segmentation of the same cases, allowing the evaluation of intraobserver reproducibility. A third segmentation was performed, using semi-automatic methodology, available in the mentioned software. For the statistical analysis, Dice similarity coefficient (DICE), Hausdorff distance (DH), comparisons between volumes and time intervals for segmentations were used. The parameters evaluated demonstrated a good intraobserver reproducibility, with DICE ranging from 0.83 to 0.97 and Hausdorff distance ranging from 3.37 to 28.73 mm. Good interobserver reproducibility was also demonstrated with DICE ranging from 0.73 to 0.97 and Hausdorff distance ranging from 3.93 to 33.40 mm. Semiautomatic segmentation demonstrated good similarity to manual segmentation (DICE ranging from 0.71 to 0.96 and HD ranging from 5.38 to 31.54mm), and there was significant reduction in the time required for segmentation. Among all the situations compared, the volumes did not present significant statistical differences (p-value> 0.05).
 
WARNING - Viewing this document is conditioned on your acceptance of the following terms of use:
This document is only for private use for research and teaching activities. Reproduction for commercial use is forbidden. This rights cover the whole data about this document as well as its contents. Any uses or copies of this document in whole or in part must include the author's name.
Publishing Date
2018-07-16
 
WARNING: Learn what derived works are clicking here.
All rights of the thesis/dissertation are from the authors
CeTI-SC/STI
Digital Library of Theses and Dissertations of USP. Copyright © 2001-2024. All rights reserved.