• JoomlaWorks Simple Image Rotator
  • JoomlaWorks Simple Image Rotator
  • JoomlaWorks Simple Image Rotator
  • JoomlaWorks Simple Image Rotator
  • JoomlaWorks Simple Image Rotator
  • JoomlaWorks Simple Image Rotator
  • JoomlaWorks Simple Image Rotator
  • JoomlaWorks Simple Image Rotator
  • JoomlaWorks Simple Image Rotator
  • JoomlaWorks Simple Image Rotator
 
  Bookmark and Share
 
 
Mémoire de Maîtrise
DOI
https://doi.org/10.11606/D.17.2017.tde-02022016-103524
Document
Auteur
Nom complet
Rafael Seragioli
Adresse Mail
Unité de l'USP
Domain de Connaissance
Date de Soutenance
Editeur
Ribeirão Preto, 2015
Directeur
Jury
Barbosa, Marcello Henrique Nogueira (Président)
Herrero, Carlos Fernando Pereira da Silva
Oliveira, Renê Donizeti Ribeiro de
Titre en portugais
Comparação entre a frequência de detecção dos ligamentos denteados na coluna cervical por meio de sequência volumétrica entre os equipamentos de ressonância magnética de 1,5 Tesla e 3,0 Tesla
Mots-clés en portugais
3D COSMIC
Ligamento denteado
Ressonância magnética
Resumé en portugais
Introdução: Os ligamentos denteados são extensões da pia-máter em cada lado da medula espinhal, totalizando cerca de 20 a 21 pares de estruturas fibrosas que se conectam com a dura-máter, ancorando a medula espinhal. Esses ligamentos são importantes referências anatômicas para cirurgias envolvendo estruturas no interior do canal vertebral e, portanto, muito bem conhecidos por cirurgiões que abordam o canal vertebral. No entanto, não encontramos a descrição deste ligamento em estudos de ressonância magnética (RM). Objetivo: Nosso objetivo foi avaliar a detecção dos ligamentos denteados na coluna cervical por meio de imagens de RM em sequências de aquisição volumétrica e com alta resolução espacial, e comparar a frequência de detecção desses ligamentos nos equipamentos de 1,5 Tesla e 3,0 Tesla. Resultados: Foram avaliados 116 exames de ressonância magnética da coluna cervical, sendo observada alta frequência de detecção dos ligamentos denteados na coluna cervical utilizando sequência volumétrica 3D COSMIC, tanto no equipamento de 1,5 Tesla quanto no equipamento de 3,0 Tesla. Não houve diferença estatisticamente significativa quando comparamos a frequência de detecção dos ligamentos entre os equipamentos de RM de 1,5T e 3,0 T.
Titre en anglais
Comparison between the frequency of detection of the dentate ligament in cervical spine by means of volumetric sequence between the magnetic resonance equipment of 1,5 Tesla and 3,0 Tesla
Mots-clés en anglais
3D COSMIC
Denticulate ligament
Magnetic resonance imaging
Resumé en anglais
Introduction: Denticulate ligaments are extensions of the pia mater on each side of the spinal cord, totaling about 20 to 21 pairs of fibrous structures that connect with the dura mater, anchoring the spinal cord. These ligaments are important anatomical references for surgeries involving structures inside the spinal canal and therefore well known to surgeons who approach the spinal canal. To our knowledge, there is no previous study on the feasibility to detect the denticulate ligaments using MRI. Objective: Our aim was to evaluate the detection of denticulate ligaments in the cervical spine using high resolution magnetic resonance imaging (MRI), and to compare the frequency of detection of these ligaments in 1.5 Tesla and 3.0 Tesla equipment. Results: We evaluated 116 MRI scans of the cervical spine and observed high frequency of detection of the denticulate ligaments in the cervical spine using the volumetric sequence 3D COSMIC on both the 1,5 Tesla and 3,0 Tesla MR equipments. There was no statistically significant difference in the frequency of detection of the ligaments between the MRI equipments.
 
AVERTISSEMENT - Regarde ce document est soumise à votre acceptation des conditions d'utilisation suivantes:
Ce document est uniquement à des fins privées pour la recherche et l'enseignement. Reproduction à des fins commerciales est interdite. Cette droits couvrent l'ensemble des données sur ce document ainsi que son contenu. Toute utilisation ou de copie de ce document, en totalité ou en partie, doit inclure le nom de l'auteur.
RafaelSeragioliOrig.pdf (646.82 Kbytes)
Date de Publication
2017-04-13
 
AVERTISSEMENT: Apprenez ce que sont des œvres dérivées cliquant ici.
Tous droits de la thèse/dissertation appartiennent aux auteurs
CeTI-SC/STI
Bibliothèque Numérique de Thèses et Mémoires de l'USP. Copyright © 2001-2024. Tous droits réservés.