Master's Dissertation
DOI
https://doi.org/10.11606/D.17.2020.tde-19082020-103814
Document
Author
Full name
Maytê Assunção Ribeiro
E-mail
Institute/School/College
Knowledge Area
Date of Defense
Published
Ribeirão Preto, 2020
Supervisor
Committee
Gastaldi, Ada Clarice (President)
Borges, Marcos de Carvalho
Fonseca, Marisa de Cássia Registro
Tambascio, Joana
Title in Portuguese
Comparação das equações de referência do sistema de oscilometria de impulso em adultos e adequação para a população brasileira
Keywords in Portuguese
Oscilometria
Resistência das vias aéreas
Sistema respiratório
Valores de referência
Abstract in Portuguese
Introdução: O Sistema de Oscilometria de Impulso (IOS) permite uma avaliação compartimentada do sistema respiratório e tem sido amplamente utilizado em estudos recentes. Os parâmetros mais conhecidos e avaliados neste sistema são: Resistência (R), e a Reatância (X), que somados fornecem informações sobre a impedância total do sistema respiratório (Zsr). As equações de referência para obtenção de valores previstos na população adulta publicadas até o momento foram obtidas em faixas etárias distintas para grupos da Alemanha, Noruega, Austrália, e Japão, e não há equação disponível para a população adulta brasileira. Objetivo: Comparar os valores previstos pelas diferentes equações de referência já existentes na literatura para as variáveis do IOS com os obtidos para uma amostra na população brasileira adulta. Métodos: Foram avaliados 108 indivíduos saudáveis, com idade entre 25 a 65 anos, 49 homens e 59 mulheres que foram avaliados pela espirometria e IOS. A análise estatística foi realizada através do software R Core Team, versão 3.4.3. Resultados: Foram obtidos dados de 59 mulheres com a média de idade 40,1±13,0 e 49 homens com idade de 42,6±12,5. Quando comparado os valores obtidos com os previsto pelas três equações foram encontradas diferenças para todas as variáveis avaliadas; R5, R20 e X5, para as equações de Vogel e Smidt, Newbury e Shiota (p<0,05).Conclusão: Os valores de R5, R20 e X5 obtidos em uma amostra da população brasileira adulta são diferentes dos valores previstos pelas equações de Vogel & Smidt, Newbury e Shiota.
Title in English
Comparison of reference equations of the pulse oscillometry system in adults and adequacy for the Brazilian population
Keywords in English
Airway resistance
Oscillometry
Reference values
Respiratory system
Abstract in English
Introduction: The Impulse Oscillometry System (IOS) allows more deitaled assessment of the respiratory system and has been widely used in recent studies. The most well-known and evaluated parameters in this system are: Resistance (R), and Reactance (X), which together provide information on the total impedance of the respiratory system (Zsr). The reference equations for obtaining values foreseen in the adult population published so far were obtained in different age groups for groups in Germany, Norway, Australia, and Japan, and there is no equation available for the Brazilian adult population. Objective: To compare the values predicted by the different reference equations already existing in the literature for IOS variables with those obtained for a sample in the adult Brazilian population. Methods: 108 healthy individuals, aged 25 to 65 years, 49 men and 59 women, were evaluated by spirometry and IOS. Statistical analysis was performed using the R Core Team software, version 3.4.3. Results: Data were obtained from 59 women with a mean age of 40.1 ± 13.0 and 49 men aged 42.6 ± 12.5. When comparing the values obtained with those predicted by the three equations, differences were found for all evaluated variables; R5, R20 and X5, for the Vogel and Smidt, Newbury and Shiota equations (p <0.05). Conclusion: The values of R5, R20 and X5 obtained in a sample of the Brazilian adult population are different from the values predicted by the equations by Vogel & Smidt, Newbury and Shiota.
 
WARNING - Viewing this document is conditioned on your acceptance of the following terms of use:
This document is only for private use for research and teaching activities. Reproduction for commercial use is forbidden. This rights cover the whole data about this document as well as its contents. Any uses or copies of this document in whole or in part must include the author's name.
Publishing Date
2020-10-23
 
WARNING: Learn what derived works are clicking here.
All rights of the thesis/dissertation are from the authors
CeTI-SC/STI
Digital Library of Theses and Dissertations of USP. Copyright © 2001-2024. All rights reserved.