• JoomlaWorks Simple Image Rotator
  • JoomlaWorks Simple Image Rotator
  • JoomlaWorks Simple Image Rotator
  • JoomlaWorks Simple Image Rotator
  • JoomlaWorks Simple Image Rotator
  • JoomlaWorks Simple Image Rotator
  • JoomlaWorks Simple Image Rotator
  • JoomlaWorks Simple Image Rotator
  • JoomlaWorks Simple Image Rotator
  • JoomlaWorks Simple Image Rotator
 
  Bookmark and Share
 
 
Disertación de Maestría
DOI
https://doi.org/10.11606/D.17.2018.tde-18042018-115106
Documento
Autor
Nombre completo
Larissa Perossi Nascimento
Dirección Electrónica
Instituto/Escuela/Facultad
Área de Conocimiento
Fecha de Defensa
Publicación
Ribeirão Preto, 2017
Director
Tribunal
Gastaldi, Ada Clarice (Presidente)
Basile Filho, Anibal
Lorenzo, Valeria Amorim Pires Di
Navarro, Anderson Marliere
Título en portugués
Avaliação da função pulmonar, força e endurance muscular respiratória, resistência do sistema respiratório e capacidade funcional de pacientes com obesidade grau III e correlação com a percepção de dispneia e qualidade de vida
Palabras clave en portugués
Função pulmonar
Músculos respiratórios
Obesidade
Oscilometria de Impulso
Qualidade de vida
Resumen en portugués
Introdução: A obesidade grau III está relacionada com o alto risco de desenvolvimento de comorbidades que afetam a qualidade de vida. Nesses indivíduos, alterações do sistema respiratório podem ocorrer pela diminuição da complacência pulmonar e/ou obstrução das vias aéreas, que podem refletir na capacidade funcional. Apesar disso, a literatura é controversa quanto ao comportamento do sistema respiratório em sujeitos com obesidade grau III. Objetivo: Avaliar a função pulmonar, força e endurance muscular respiratória, resistência do sistema respiratório e capacidade funcional de mulheres com obesidade grau III e correlacionar com a percepção de dispneia e qualidade de vida. Métodos: As pacientes foram avaliadas pela espirometria, manovacuometria, teste de endurance dos músculos inspiratórios, oscilometria de impulso e teste de caminhada de seis minutos (TC6). Também foram aplicados o Questionário Internacional de Atividade Física (IPAQ), o Questionário Short Form 36 (SF-36) e a escala modificada do Medical Research Council (mMRC). Resultados: Foram avaliadas 40 mulheres com 36,4±7,6 anos e IMC igual 47,0±6,2 kg/m2. Não foram detectados distúrbios ventilatórios pela espirometria (%CVF: 95,13±13,38; %VEF1: 92,37±14,81; %VEF1/CVF: 97,21±7,25; %FEF25-75%: 86,26±27,00) enquanto que a oscilometria de impulso identificou alterações significantes na resistência das vias aéreas (kPa/L/s) em relação ao previsto (R5: 0,56±0,15 e 0,36±0,01; R20: 0,41±0,08 e 0,30±0,01; R5-20: 0,16±0,09 e 0,06±0,00; X5: -0,24±0,10 e -0,03±0,02). A média dos valores obtidos da PImáx e PEmáx (cmH2O) foi de -114,7±24,3 e 132,0±30,1; respectivamente e, o tempo de endurance dos músculos inspiratórios foi inferior ao esperado para 47% das voluntárias. A distância percorrida no TC6 não apresentou diferença significativa em relação aos valores previstos. As participantes não tiveram queixa de dispneia importante e referiram bom estado geral de saúde no SF-36. Não foram observadas correlações fortes entre a percepção de dispneia e a qualidade de vida com os resultados dos testes da avaliação. Conclusão: Os resultados do IOS sugerem obstrução das vias aéreas centrais e periféricas, que não foram detectadas pela espirometria. As pacientes relataram boa percepção da qualidade de vida e baixa sensação de dispneia, com bom desempenho no TC6 e sem fraqueza dos músculos respiratórios, porém com limitação do tempo de endurance dos músculos inspiratórios.
Título en inglés
Evaluation of pulmonary function, respiratory muscle strength and endurance, respiratory system resistance and functional capacity of grade III obesity patients and correlation with the dyspnea perception and quality of life
Palabras clave en inglés
Impulse oscillometry
Obesity
Pulmonary function
Quality of life
Respiratory muscles
Resumen en inglés
Introduction: Grade III obesity is related to risk of developing comorbidities that can influence the quality of life. In this population, respiratory dysfunctions can occur by the pulmonary complacency decrease and/or airways obstruction that can affect the functional lung capacity. Despite this, there are disagreements in the literature about the respiratory system behavior in severely obese subjects. Objective: To evaluate respiratory muscle strength, inspiratory muscle endurance, respiratory system resistance and, functional capacity and to correlate these parameters with dyspnea and quality of life perceptions. Methods: The participants were evaluated by spirometry, manovacuometry, inspiratory muscle endurance test, impulse oscillometry (IOS) and the six minute walk test (6MWT). They also answered the International Physical Activity Questionnaire (IPAQ), Quality of Life Questionnaire (SF-36) and the modified Medical Research Council scale (mMRC). Results: We evaluated 40 women with mean age of 36.3±7.9 years and body mass index of 47.1±6.3 kg/m2. The spirometry exam did not detect pulmonary function dysfunctions (%FEV1: 92.4±14.8; %FVC: 95.3±13.4; %FEV1/FVC: 97.2±7.3 and %FEF25-75%: 86.3±27.0). The IOS detected alterations in the airways resistance in comparison to the predicted values (kPa/L/ s) (R5: 0.56±0.15 and 0.36±0.01, R20: 0.41±0.08 and 0.30±0.01, R5-20: 0.16±0.09 and 0.06±0.00, X5: -0.24±0.10 and -0.03±0.02, respectively) (p<0.05). The mean maximum inspiratory and expiratory pressures (cmH2O) were -114.7±24.3 and 132.0±30.1, respectively; and the inspiratory muscle endurance time was under the expected value in nearly 50% of the participants. The six minute walked distance did not show statistical differences compared to the predicted value. According to the mMRC, the participants did not have relevant dyspnea complaints and reported good quality of life perception by the SF-36. We did not find strong correlations between quality of life and dyspnea perception with the variables of protocol assessment. Conclusion: The IOS results suggest central and peripheral airway obstruction, which were not detected by spirometry. Patients reported good quality of life and low dyspnea perceptions. They had good performance in the 6MWT without respiratory muscle weakness but with limitations in inspiratory muscle endurance time.
 
ADVERTENCIA - La consulta de este documento queda condicionada a la aceptación de las siguientes condiciones de uso:
Este documento es únicamente para usos privados enmarcados en actividades de investigación y docencia. No se autoriza su reproducción con finalidades de lucro. Esta reserva de derechos afecta tanto los datos del documento como a sus contenidos. En la utilización o cita de partes del documento es obligado indicar el nombre de la persona autora.
Fecha de Publicación
2018-07-20
 
ADVERTENCIA: Aprenda que son los trabajos derivados haciendo clic aquí.
Todos los derechos de la tesis/disertación pertenecen a los autores
CeTI-SC/STI
Biblioteca Digital de Tesis y Disertaciones de la USP. Copyright © 2001-2024. Todos los derechos reservados.