• JoomlaWorks Simple Image Rotator
  • JoomlaWorks Simple Image Rotator
  • JoomlaWorks Simple Image Rotator
  • JoomlaWorks Simple Image Rotator
  • JoomlaWorks Simple Image Rotator
  • JoomlaWorks Simple Image Rotator
  • JoomlaWorks Simple Image Rotator
  • JoomlaWorks Simple Image Rotator
  • JoomlaWorks Simple Image Rotator
  • JoomlaWorks Simple Image Rotator
 
  Bookmark and Share
 
 
Master's Dissertation
DOI
https://doi.org/10.11606/D.17.2018.tde-17042018-141102
Document
Author
Full name
Giseli Rebechi
E-mail
Institute/School/College
Knowledge Area
Date of Defense
Published
Ribeirão Preto, 2018
Supervisor
Committee
Tamashiro, Edwin (President)
Martins, Regina Helena Garcia
Ricz, Hilton Marcos Alves
Valera, Fabiana Cardoso Pereira
Title in Portuguese
Avaliação da histocompatibilidade do implante de ácido glicólico/ácido lático (PLGA) na laringe de coelhos
Keywords in Portuguese
Colágeno; Histologia; Implante; Laringe
Abstract in Portuguese
Introdução: Diversas afecções laríngeas exigem o uso de enxertos para correção de insuficiências anatômicas ou de múltipla aplicação de fármacos para controle da doença. Alguns bioimplantes, especialmente aqueles com propriedades de liberação controlada de drogas, podem ser úteis no tratamento dessas afecções laríngeas, como a papilomatose laríngea. O poli ácido lático-co-glicólico (PLGA), tem sido bastante testado em aplicações intraoculares e topicamente na cavidade nasal, com resultados bastante promissores. No entanto, um implante de PLGA nunca foi avaliado quanto à sua biocompatibilidade em tecidos laríngeos. Objetivo: Avaliar as alterações histológicas decorrentes da aplicação de PLGA em laringes de coelhos. Materiais e Métodos: Grupos de sete a oito coelhos foram sacrificados em diferentes tempos pós-manipulação cirúrgica (1, 2, 4 e 8 semanas), comparando o lado implantado com PLGA e o lado sham-operado. Os achados histopatológicos foram comparados entre os dois grupos em cada tempo cirúrgico, assim como foi avaliada a diferença comparada a laringes não manipuladas. Resultados: A implantação de PLGA promoveu maior infiltração de células inflamatórias, indução de fibrose e neovascularização até a 4ª semana pós-operatória avaliada. No entanto, após oito semanas de evolução, as hemilaringes implantadas com PLGA se apresentaram semelhantes às laringes sham-operadas, ou mesmo não manipuladas cirurgicamente, com retorno quase que completo às condições basais. Por outro lado, não houve diferença da quantidade de depósito de colágeno tipo I e III nas hemilaringes implantadas com PLGA, em nenhum dos tempos avaliados. Conclusão: O implante de PLGA parece ser seguro para aplicações intralaríngeas, produzindo reações inflamatórias nas quatro primeiras semanas, mas que são reversíveis em oito semanas.
Title in English
Evaluation of histocompatibility of poly lactic-glycolic acid graft in rabbit larinx
Keywords in English
Collagen; Histology; Implant; Larynx
Abstract in English
Introduction: Several laryngeal affections require the use of grafts to correct anatomical insufficiencies or multiple application of drugs to control the disease. Some bioimplants, especially those with controlled drug release properties, may be useful in the treatment of such laryngeal conditions, such as laryngeal papillomatosis. Poly (lactic acid-co-glycolic acid), PLGA, has been widely tested in intraocular and nasal cavity applications, with very promising results. However, a PLGA implant has never been assessed for its biocompatibility in laryngeal tissues. Aim: To evaluate the histological changes resulting from the application of PLGA in rabbit larynx. Materials and Methods: Groups of 7-8 rabbits were sacrificed at different postsurgical times (1, 2, 4, and 8 weeks), comparing the implanted side with PLGA and the sham-operated side. Histopathological findings were compared between the two groups at each surgical time, as was the difference compared to the non-surgically manipulated larynx. Results: PLGA implantation promoted a higher infiltration of inflammatory cells, induction of fibrosis and neovascularization until the 4th postoperative week evaluated. However, after 8 weeks of evolution, PLGA implanted hemilarynx were similar to sham-operated or even non-surgically manipulated larynx, with a complete return to baseline conditions. On the other hand, there was no difference in the amount of collagen deposition type I and III in the hemilarynx implanted with PLGA, in none of the evaluated times. Conclusion: The PLGA implant appears to be safe for intralaryngeal applications, producing inflammatory reactions in the first 4 weeks, but which are reversible within 8 weeks.
 
WARNING - Viewing this document is conditioned on your acceptance of the following terms of use:
This document is only for private use for research and teaching activities. Reproduction for commercial use is forbidden. This rights cover the whole data about this document as well as its contents. Any uses or copies of this document in whole or in part must include the author's name.
GISELIREBECHI.pdf (1.57 Mbytes)
Publishing Date
2018-06-13
 
WARNING: Learn what derived works are clicking here.
All rights of the thesis/dissertation are from the authors
CeTI-SC/STI
Digital Library of Theses and Dissertations of USP. Copyright © 2001-2024. All rights reserved.