• JoomlaWorks Simple Image Rotator
  • JoomlaWorks Simple Image Rotator
  • JoomlaWorks Simple Image Rotator
  • JoomlaWorks Simple Image Rotator
  • JoomlaWorks Simple Image Rotator
  • JoomlaWorks Simple Image Rotator
  • JoomlaWorks Simple Image Rotator
  • JoomlaWorks Simple Image Rotator
  • JoomlaWorks Simple Image Rotator
  • JoomlaWorks Simple Image Rotator
 
  Bookmark and Share
 
 
Doctoral Thesis
DOI
https://doi.org/10.11606/T.17.2019.tde-17072019-101516
Document
Author
Full name
Ana Elizabeth Gomes de Melo Tavares Ferreira
E-mail
Institute/School/College
Knowledge Area
Date of Defense
Published
Ribeirão Preto, 2019
Supervisor
Committee
Mauad Filho, Francisco (President)
Costa, Fabricio da Silva
Júnior, Edward Araujo
Pastore, Ayrton Roberto
Title in Portuguese
Reprodutibilidade da medida do comprimento do colo uterino por ultrassonografia
Keywords in Portuguese
Colo curto
Comprimento do colo uterino
Concordância
Medida do colo uterino por ultrassonografia
Predição do parto prematuro
Reprodutibilidade
Ultrassonografia do colo uterino
Abstract in Portuguese
O parto pré-termo é uma causa importante de morbidade e mortalidade neonatal. A medida do comprimento do colo uterino por ultrassonografia, atualmente, é utilizada para o rastreamento desta condição. Porém, não se sabe, exatamente, qual é a sua reprodutibilidade, ou seja, se a via vaginal é melhor que a abdominal e se a ultrassonografia tridimensional pode contribuir para melhorar a reprodutibilidade do método. O objetivo desse trabalho foi avaliar a reprodutibilidade da medida do comprimento do colo uterino no final do segundo trimestre da gestação por ultrassonografia bidimensional (2D) e tridimensional (3D), utilizando as vias abdominal e vaginal. Foram avaliadas 96 mulheres com idade gestacional entre 20 e 26 semanas. Durante as avaliações, foram realizadas três medidas completamente independentes e com mascaramento: duas feitas por um observador, intercaladas por uma medida de um segundo observador. Foram avaliados o coeficiente de correlação de concordância (CCC) e os limites de concordância (LoA). A precisão das estimativas será avaliada pelo intervalo de confiança de 95%. As principais características das 96 mulheres analisadas foram: idade = 25,0 ± 5,4 anos, IG = 22,5 ± 2,0 semanas, índice de massa corporal = 26,0 ± 3,2 Kg / m². TV-US e TA-US fornecem medições de CL semelhantes, no entanto, a US-TV apresentou uma reprodutibilidade ligeiramente melhor (CCC intraobservador: US-TV 0,90 (0,86-0,93) US-TA 0,83 (0,76-0,88); CCC interobservador: US-TV 0,77 (0,68-0,84) US-TA 0,60 (0,45-0,71). A medida do CL durante o segundo trimestre deve ser interpretada com cautela quando utilizada na prática clínica, pois sua reprodutibilidade é apenas fraca a moderada. Estudos que examinem refinamentos técnicos para melhorar sua reprodutibilidade devem ser encorajados
Title in English
Cervical length measured by ultrasound: a reproducibility study
Keywords in English
Cervix length
Measurement of uterine cervix by ultrasonography
Preterm birth screening
Reliability
Reproducibility
Short cervix
Uterine cervix ultrasound
Abstract in English
Preterm birth is an important cause of neonatal morbidity and mortality. Ultrasound measurement of uterine cervix length is currently used to predict this condition. Nevertheless, its reproducibility has not been clearly evaluating in the literature, in other words, what is the best ultrasound method to measure, for instance, the vaginal via or the abdominal. The objective of this study was to evaluate the reproducibility of the measurement of uterine cervix length at the end of the second trimester of gestation by two-dimensional (2D) using the via abdominal and vaginal. We evaluated 96 healthy singleton pregnant women with gestational age between 20 and 26 weeks. During the evaluations, three completely independent and masked measurements were performed: two made by one observer, interspersed by a second observer measurement. The correlation coefficient of agreement (CCC) and the limits of agreement (LoA) were evaluated. The accuracy of the estimates will be evaluated by the 95% confidence interval. The main characteristics of the 96 analyzed women were: age = 25.0 ± 5.4 years, GA = 22.5 ± 2.0 weeks, body mass index = 26.0 ± 3.2 Kg/m². TVUS and TA-US provides similar CL measurements; however, TV-US has a slightly better reproducibility (CCC intraobservador: US-TV 0,90 (0,86-0,93) US-TA 0,83 (0,76-0,88); CCC interobservador: US-TV 0,77 (0,68-0,84) US-TA 0,60 (0,45-0,71). The CL measurement during the second trimester should be interpreted with caution when employed in clinical practice because its reproducibility is only poor to moderate. Studies examining technical refinements to improve its reproducibility should be encouraged
 
WARNING - Viewing this document is conditioned on your acceptance of the following terms of use:
This document is only for private use for research and teaching activities. Reproduction for commercial use is forbidden. This rights cover the whole data about this document as well as its contents. Any uses or copies of this document in whole or in part must include the author's name.
Publishing Date
2019-08-07
 
WARNING: Learn what derived works are clicking here.
All rights of the thesis/dissertation are from the authors
CeTI-SC/STI
Digital Library of Theses and Dissertations of USP. Copyright © 2001-2024. All rights reserved.