• JoomlaWorks Simple Image Rotator
  • JoomlaWorks Simple Image Rotator
  • JoomlaWorks Simple Image Rotator
  • JoomlaWorks Simple Image Rotator
  • JoomlaWorks Simple Image Rotator
  • JoomlaWorks Simple Image Rotator
  • JoomlaWorks Simple Image Rotator
  • JoomlaWorks Simple Image Rotator
  • JoomlaWorks Simple Image Rotator
  • JoomlaWorks Simple Image Rotator
 
  Bookmark and Share
 
 
Disertación de Maestría
DOI
https://doi.org/10.11606/D.17.2020.tde-25082020-093429
Documento
Autor
Nombre completo
Raffaello de Freitas Miranda
Dirección Electrónica
Instituto/Escuela/Facultad
Área de Conocimiento
Fecha de Defensa
Publicación
Ribeirão Preto, 2020
Director
Tribunal
Defino, Helton Luiz Aparecido (Presidente)
Engel, Edgard Eduard
Mandarano Filho, Luiz Garcia
Pagnano, Rodrigo Gonçalves
Título en portugués
Influência do diâmetro e desenho do macheamento do orifício piloto nas propriedades biomecânicas do parafuso pedicular
Palabras clave en portugués
Coluna vertebral
Osteoporose
Parafusos pediculares
Torção mecânica
Resumen en portugués
Objetivo: Estudar experimentalmente por meio de ensaios mecânicos a influência do macheamento do orifício piloto com machos de diâmetros igual e inferior ao diâmetro externo do parafuso, e desenhos de rosca não congruentes, sobre a resistência ao arrancamento dos parafusos do sistema de fixação pedicular. Métodos: Parafusos pediculares de 5,5 mm e 6,5 mm de diâmetro pertencentes a três sistemas de fixação vertebral comercialmente disponíveis (Legacy, Solera e Revere) foram inseridos em blocos de poliuretano com densidade de 10PCF (0,16g / cm3). De acordo com o grupo experimental, os parafusos foram inseridos após preparar o orifício piloto com macho de passo de rosca congruente ou incongruente, e de diâmetro igual ou menor que o diâmetro do parafuso do sistema de fixação vertebral. Os testes de resistência ao arrancamento dos parafusos pediculares foram realizados utilizando máquina de teste universal após a inserção dos parafusos nos blocos de poliuretano. Resultados: O macheamento, com a utilização de macho, de menor diâmetro e passo de rosca semelhante ao parafuso aumentou a resistência ao arrancamento dos parafusos. A utilização de macheamento não congruente e de menor diâmetro mostrou resultados não homogêneos. Não foi observada diferença estatística na força da resistência ao arrancamento dos parafusos de 5,5 mm e 6,5mm com a utilização de macheamento com machos de menor diâmetro e passo de rosca incongruente. Conclusão: A utilização e macheamento do orifício com desenho do passo de rosca diferente do parafuso pedicular não diminui a força de arrancamento dos parafusos de todas as modalidades de parafusos testadas no estudo, e seu desempenho de arrancamento dos parafusos depende de outros fatores, como o desenho da rosca.
Título en inglés
Influence of the diameter and design of the pilot hole tapping on the biomechanical properties of the pedicular screw
Palabras clave en inglés
Mechanical torsion
Osteoporosis
Pedicle screws
Spine
Resumen en inglés
Objective: To study experimentally by mechanical testing the influence of pilot hole tapping with male diameters equal to and less than the outside diameter of the screw, and non-congruent thread designs, on the pullout strength of the pedicular fixation screws. Methods: 5.5 mm and 6.5 mm diameter pedicle screws belonging to three commercially available vertebral fixation systems (Legacy, Solera and Revere) were inserted into polyurethane blocks with density of 10PCF (0.16g / cm3). According to the experimental group, the screws were inserted after preparing the pilot hole with congruent or incongruent thread pitch male, and with a diameter equal to or smaller than the screw diameter of the vertebral fixation system. The pullout resistance tests of the pedicle screws were performed using a universal testing machine after the insertion of the screws in the polyurethane blocks. Results: Tapping, with the use of a smaller diameter tapered screw pitch, increased the pullout strength of the screws. The use of non-congruent and smaller diameter tapping showed inhomogeneous results. No statistical difference was observed in the pullout strength of the 5.5 mm and 6.5 mm screws with tapping with smaller diameter males and incongruent screw pitch.Conclusion: The use and tapping of the hole with thread pitch design different from the pedicular screw does not decrease the screw pullout strength of all screw types tested in the study, and its screw pullout performance depends on other factors, such as thread drawing.
 
ADVERTENCIA - La consulta de este documento queda condicionada a la aceptación de las siguientes condiciones de uso:
Este documento es únicamente para usos privados enmarcados en actividades de investigación y docencia. No se autoriza su reproducción con finalidades de lucro. Esta reserva de derechos afecta tanto los datos del documento como a sus contenidos. En la utilización o cita de partes del documento es obligado indicar el nombre de la persona autora.
Fecha de Publicación
2020-10-21
 
ADVERTENCIA: Aprenda que son los trabajos derivados haciendo clic aquí.
Todos los derechos de la tesis/disertación pertenecen a los autores
CeTI-SC/STI
Biblioteca Digital de Tesis y Disertaciones de la USP. Copyright © 2001-2024. Todos los derechos reservados.