Disertación de Maestría
DOI
https://doi.org/10.11606/D.17.2020.tde-07092020-103452
Documento
Autor
Nombre completo
Kelsen de Oliveira Teixeira
Dirección Electrónica
Instituto/Escuela/Facultad
Área de Conocimiento
Fecha de Defensa
Publicación
Ribeirão Preto, 2020
Director
Tribunal
Defino, Helton Luiz Aparecido (Presidente)
Botelho, Ricardo Vieira
Fazan, Valeria Paula Sassoli
Título en portugués
Avaliação do uso de guias para posicionamento de parafusos pediculares em cirurgias de correção de escoliose
Palabras clave en portugués
Coluna vertebral
Escoliose
Fusão vertebral
Impressão em 3D
Parafusos pediculares
Resumen en portugués
Introdução: Foram desenvolvidos protótipos de guias customizados para pacientes com deformidade da coluna vertebral para auxiliar no preparo do orifício piloto e reduzir a exposição à radiação. O objetivo do estudo foi o desenvolvimento dos guias customizados e avaliação da sua utilização nos pacientes submetidos à cirurgia de correção de deformidade vertebral com sistema de fixação pedicular. Material e Método: Estudo prospectivo e intervencionista em quatro pacientes com deformidade da coluna vertebral (três escolioses idiopáticas e uma cifoescoliose congênita) submetidos a tratamento cirúrgico para a correção da deformidade com sistema de fixação pedicular. Foram desenvolvidos protótipos de guias customizados 3D, e a sua utilização foi avaliada por meio da viabilidade técnica, acurácia e exposição à radiação. Resultados: Foram considerados no estudo o conjunto de 85 pedículos vertebrais nos quais os parafusos pediculares foram inseridos (56/65,8% torácicos e 29/34,2% lombares). A viabilidade técnica foi positiva em 46 (54,1%) pedículos vertebrais, sendo 25 (54%) pedículos torácicos e 21 (46%) lombares. A viabilidade técnica foi negativa em 39 (45,9%) pedículos, sendo 31 (79,5%) torácicos e 8 (20,5%) lombares. Na avaliação da acurácia, 36 (78,2%) parafusos estavam centralizados, sendo 17 (36,9%) na coluna torácica e 19 (41,3%) na coluna lombar. Foi observado mal posicionamento em 10 (21,7%) parafusos, sendo 8 (17,4%) na coluna torácica e 2 (4,3%) na coluna lombar. O registro da média da radiação utilizada nos procedimentos cirúrgicos foi 32,34 mGy e o tempo total de uso da fluoroscopia em cada cirurgia variou de 180,3 a 207,2 segundos. Conclusão: Os protótipos de guias customizados permitiram o preparo seguro do orifício piloto dos pedículos vertebrais nos pacientes com deformidades com melhora da acurácia e redução da radiação intra-operatória.
Título en inglés
Evaluation of the use of guides for positioning pedicle screws in scoliosis correction surgery
Palabras clave en inglés
3D printing
Pedicle screws
Scoliosis
Spinal fusion
Spine
Resumen en inglés
Background: Prototypes of customized guides have been developed for patients with spinal deformity to assist in preparing the pilot orifice and reduce radiation exposure. The aim of the study was to develop customized guides and evaluate their use in patients undergoing surgery to correct spinal deformity with a pedicular fixation system. Methods / Designs: Prospective and interventional study in four patients with spinal deformity (three idiopathic scoliosis and one congenital kyphoscoliosis) who underwent surgical treatment to correct the deformity with a pedicular fixation system. Prototypes of customized 3D guides were developed, and their use was evaluated through technical feasibility, accuracy and radiation exposure. Results: The study included 85 vertebral pedicles in which pedicle screws were inserted (56 / 65.8% thoracic and 29 / 34.2% lumbar). Technical feasibility was positive in 46 (54.1%) vertebral pedicles, with 25 (54%) thoracic and 21 (46%) lumbar pedicles. Technical feasibility was negative in 39 (45.9%) pedicles, of which 31 (79.5%) were thoracic and 8 (20.5%) were lumbar. In assessing accuracy, 36 (78.2%) screws were centralized, 17 (36.9%) in the thoracic spine and 19 (41.3%) in the lumbar spine. Malposition was observed in 10 (21.7%) screws, 8 (17.4%) in the thoracic spine and 2 (4.3%) in the lumbar spine. The average radiation record used in surgical procedures was 32.34 mGy and the total time of use of fluoroscopy in each surgery ranged from 180.3 to 207.2 seconds. Conclusion: The prototypes of customized guides allowed the safe preparation of the pilot orifice of the vertebral pedicles in patients with deformities with improved accuracy and reduced intraoperative radiation.
 
ADVERTENCIA - La consulta de este documento queda condicionada a la aceptación de las siguientes condiciones de uso:
Este documento es únicamente para usos privados enmarcados en actividades de investigación y docencia. No se autoriza su reproducción con finalidades de lucro. Esta reserva de derechos afecta tanto los datos del documento como a sus contenidos. En la utilización o cita de partes del documento es obligado indicar el nombre de la persona autora.
Fecha de Publicación
2020-10-26
 
ADVERTENCIA: Aprenda que son los trabajos derivados haciendo clic aquí.
Todos los derechos de la tesis/disertación pertenecen a los autores
CeTI-SC/STI
Biblioteca Digital de Tesis y Disertaciones de la USP. Copyright © 2001-2024. Todos los derechos reservados.