Disertación de Maestría
DOI
https://doi.org/10.11606/D.17.2020.tde-05102020-100348
Documento
Autor
Nombre completo
Thiago Dantas Matos
Dirección Electrónica
Instituto/Escuela/Facultad
Área de Conocimiento
Fecha de Defensa
Publicación
Ribeirão Preto, 2020
Director
Tribunal
Defino, Helton Luiz Aparecido (Presidente)
Botelho, Ricardo Vieira
Tirapelli, Luis Fernando
Título en portugués
Alteração morfológica do forâmen lombar e lordose segmentar relacionadas ao posicionamento do espaçador intersomático na artrodese lombar intersomática transforaminal
Palabras clave en portugués
Coluna vertebral
Fusão vertebral
Lordose
Resumen en portugués
A artrodese lombar intersomática transforaminal (TLIF) é um importante procedimento que tem sido utilizada para o tratamento de doenças degenerativas que acometem a coluna lombar. O objetivo do estudo foi avaliar as alterações morfológicas do forâmen intervertebral e da lordose segmentar relacionadas ao posicionamento do espaçador intersomático e realização de facetectomia uni ou bilateral na artrodese lombar intersomática transforaminal (TLIF). Materiais e Métodos: Espaçadores de PEEK foram colocados no espaço discal (L1-S1) de modelo anatômico de poliuretana. Os espaçadores de diferentes alturas (8, 10, 12 e 14 mm) foram posicionados na parte posterior, média ou anterior da superfície do corpo vertebral e a altura do forame intervertebral e lordose segmentar mensuradas após a sua inserção, com técnica de facetectomia uni ou bilateral. Resultado: Foi observado redução da altura do forâmen intervertebral em todos os posicionamentos e alturas dos espaçadores em relação ao controle. O posicionamento posterior do espaçador induziu à menor redução da altura do forâmen vertebral. A lordose do semento vertebral apresentou tendência de aumento em relação ao controle, tendo sido observado a maior tendência com o posicionamento posterior do espaçador. Não houve diferença significante com a realização de facetectomia bilateral na altura do forame intervertebral e houve uma tendência ao aumento da lordose. Conclusão: O posicionamento do espaçador induz a alterações da altura do forame intervertebral e lordose do segmento vertebral. O posicionamento posterior do espaçador induz a menor redução da altura do forame intervertebral e aumento da lordose do segmento vertebral.
Título en inglés
Morphologic changes of lumbar foramen and segmental lordosis related to cage position in transforaminal lumbar interbody fusion
Palabras clave en inglés
Lordosis
Spinal fusion
Spine
Resumen en inglés
Transforaminal lumbar interbody fusion (TLIF) is an important procedure that has been used in the treatment of lumbar spine degenerative disease. The aim of this study was to evaluate the morphological alterations of intervertebral foramen and segmental lordosis related to the positioning of the intersomatic spacer and facetectomy uni or bilateral in transforaminal interbody lumbar fusion (TLIF). Methods / Designs: PEEK Cages were placed in the disc space (L1-S1) of polyurethane anterograde model. The Cages of different heights (8, 10, 12 and 14 mm) were positioned in the posterior, middle or anterior part of the surface of the vertebral body and the height of the intervertebral foramina and segmental lordosis measured after their insertion, with uni or bilateral facetectomy technique. Results: The height of the vertebral foramen was observed in all the positions and heights of the Cages in relation to the control. Posterior positioning of the Cage induced a smaller reduction in the height of the vertebral foramen. Vertebral lordosis presented a tendency to increase in relation to the control, and the greatest tendency was observed with the posterior positioning of the Cage. There was no statistic difference in the height of lumbar foramen when performing facetectomy bilaterally, and there was a tendency to increase lordosis. Conclusion: The positioning of the Cage induces changes in the height of the intervertebral foramen and lordosis of the vertebral segment. The posterior positioning of the Cage induces the smaller reduction of the height of the intervertebral foramen and increase of the lordosis of the vertebral segment.
 
ADVERTENCIA - La consulta de este documento queda condicionada a la aceptación de las siguientes condiciones de uso:
Este documento es únicamente para usos privados enmarcados en actividades de investigación y docencia. No se autoriza su reproducción con finalidades de lucro. Esta reserva de derechos afecta tanto los datos del documento como a sus contenidos. En la utilización o cita de partes del documento es obligado indicar el nombre de la persona autora.
Fecha de Publicación
2020-10-20
 
ADVERTENCIA: Aprenda que son los trabajos derivados haciendo clic aquí.
Todos los derechos de la tesis/disertación pertenecen a los autores
CeTI-SC/STI
Biblioteca Digital de Tesis y Disertaciones de la USP. Copyright © 2001-2024. Todos los derechos reservados.