• JoomlaWorks Simple Image Rotator
  • JoomlaWorks Simple Image Rotator
  • JoomlaWorks Simple Image Rotator
  • JoomlaWorks Simple Image Rotator
  • JoomlaWorks Simple Image Rotator
  • JoomlaWorks Simple Image Rotator
  • JoomlaWorks Simple Image Rotator
  • JoomlaWorks Simple Image Rotator
  • JoomlaWorks Simple Image Rotator
  • JoomlaWorks Simple Image Rotator
 
  Bookmark and Share
 
 
Mémoire de Maîtrise
DOI
https://doi.org/10.11606/D.17.2006.tde-21092006-143828
Document
Auteur
Nom complet
Luciano Albuquerque Lima Saraiva
Unité de l'USP
Domain de Connaissance
Date de Soutenance
Editeur
Ribeirão Preto, 2006
Directeur
Jury
Santos, Antonio Carlos dos (Président)
Marques, Paulo Mazzoncini de Azevedo
Murta Junior, Luiz Otavio
Titre en portugais
Desenvolvimento de software para processamento de imagens quantitativas em ressonância magnética
Mots-clés en portugais
desenvolvimento de software
DICOM
imagem médica
processamento de imagens
ressonância magnética
transferência de magnetização
Resumé en portugais
O uso de análise quantitativa em radiologia médica tem sido de grande valia na detecção de alterações não acessíveis à análise visual simples, dita qualitativa, seja por serem muito sutis, seja por não estarem presentes nas técnicas de imagem de ressonância magnética convencional. Porém, certos tipos de quantificação exigem a aquisição softwares e de plataformas computacionais de alto custo, além de mão de obra especializada com conhecimento técnico em computação para operar em ambientes não intuitivos. Neste cenário o objetivo deste trabalho foi a implementação de um software para análise de transferência de magnetização em imagens de ressonância magnética nuclear que funcionasse na plataforma IBM-PC e em sistemas operacionais livres como GNU/Linux. Com este intuito foi elaborado um algoritmo para leitura de imagens codificadas no padrão DICOM 3.0, um algoritmo para a construção dos mapas de Razão de Transferência de Magnetização do volume adquirido e um visualizador com interface amigável para a segmentação e análise dos resultados. Ao final, software possibilitou a abertura da imagem DICOM. Também construiu de maneira eficiente, os mapas de diferença de porcentagem entre as imagens sem e com o pulso de transferência de magnetização (MTR), possibilitando, inclusive, correções de artefatos de movimentos, quando pouco intensos. Permitiu o delineamento de regiões de interesse irregular, com boa visibilidade dos resultados. Como controle padrão, os resultados foram comparados com o conjunto de ferramentas da Universidade McGill (Brain Imaging Center, McGuill University, Montreal, Quebec, Canadá), amplamente testado em artigos publicados.
Titre en anglais
Development of software for quantitative image processing in magnetic resonance
Mots-clés en anglais
DICOM
image processing
magnetic resonance
Magnetization Transfer
medical image
software development
Resumé en anglais
The use of quantitative analysis in medical radiology has been of great value in the detection of not accessible alterations in the simple visual analysis, said qualitative, for being very subtle, or for not being present in conventional magnetic resonance image techniques. However, certain types of quantification demand the acquisition of high cost softwares and computational platforms, beyond specialized workmanship, with technical knowledge in computation, to operate in non intuitive environments. In this scenery the objective of this work was the implementation of a software for analysis of transference of magneti zation in nuclear magnetic resonance images that works in IBM-PC platform and free operational systems as GNU/Linux. So, an algorithm for reading of standard DICOM 3.0 codified images was elaborated, an algorithm for the construction of Magnetization Transfer Ratio maps of acquired volume, and a visualizer with friendly interface for segmentation and analysis of the results. Finally the software made the opening of DICOM image possible. It also generated in efficient way the maps of percentage difference among the images without and with the pulse of magnetization transfer (MT), also making devices of movement corrections possible, when they are not very intense. It allowed the delineation of regions of irregular interest, with good visibility of the results. As standard control, the results were compared with the set of tools of the McGill University (Brain Imaging Center, McGuill University, Montreal, Quebec, Canada), widely tested in published articles. The elaborated program took care of the considered objectives.
 
AVERTISSEMENT - Regarde ce document est soumise à votre acceptation des conditions d'utilisation suivantes:
Ce document est uniquement à des fins privées pour la recherche et l'enseignement. Reproduction à des fins commerciales est interdite. Cette droits couvrent l'ensemble des données sur ce document ainsi que son contenu. Toute utilisation ou de copie de ce document, en totalité ou en partie, doit inclure le nom de l'auteur.
final.pdf (3.79 Mbytes)
Date de Publication
2008-02-01
 
AVERTISSEMENT: Apprenez ce que sont des œvres dérivées cliquant ici.
Tous droits de la thèse/dissertation appartiennent aux auteurs
CeTI-SC/STI
Bibliothèque Numérique de Thèses et Mémoires de l'USP. Copyright © 2001-2024. Tous droits réservés.