Mémoire de Maîtrise
DOI
https://doi.org/10.11606/D.17.2017.tde-30032017-135743
Document
Auteur
Nom complet
Aline Aparecida Simsic
Adresse Mail
Unité de l'USP
Domain de Connaissance
Date de Soutenance
Editeur
Ribeirão Preto, 2016
Directeur
Jury
Martinez, Jose Antonio Baddini (Président)
Regueiro, Eloisa Maria Gatti
Miranda, Carlos Henrique
Titre en portugais
Tradução e validação da escala Dyspnoea-12 para o português falado no Brasil em pacientes com DPOC e hipertensão pulmonar
Mots-clés en portugais
Dispneia
DPOC
Hipertensão Pulmonar
Resumé en portugais
Objetivo: Traduzir e adaptar para o português falado no Brasil a escala Dyspnoea-12. Fornecer dados de validação da escala para pacientes com DPOC e hipertensão pulmonar (HP). Métodos: A versão em inglês da escala Dyspnoea-12 sofreu processo clássico de tradução, até obtenção de versão definitiva em português denominada Dispneia-12-Pt. A escala Dispneia-12-Pt foi aplicada a 51 pacientes com DPOC (33 homens; idade: 66,4±8,1 anos; VEF1: 48,7±17,2%) e 15 com HP de diferentes etiologias (12 mulheres; idade: 45,8±12,7 anos; pressão sistólica da artéria pulmonar: 88±33,2 mmHg). Os voluntários responderam a escala de dispneia do Medical Research Council(MRC), o índice de dispneia basal (IDB), a escala hospitalar de ansiedade e depressão, questionário respiratório de Saint George (QRSG), avaliação funcional respiratória e teste da caminhada dos seis minutos (TC6min). Sessenta voluntários responderam a escala uma segunda vez, duas semanas após a primeira avaliação. Resultados: No grupo DPOC a escala Dispneia-12-Pt apresentou correlações significantes com as escalas MRC (r=0,4641; p=0,0006), IDB (r=0,515; p <0,0001), QRSG (r=0,8113; p<0,0001), ansiedade (r=0,4714; p=0,0005), depressão (0,4139; p=0,0025) e distância percorrida no TC6min (r=0,3293; p=0,0255). No grupo com HP a escala mostrou correlações significantes com as escalas MRC (r=0,5774; p=0,0242), QRSG (r=0,6907; p=0,0044), distância percorrida no TC6min (r=0,7193; p=0,0025) e difusão do monóxido de carbono (r=0,564; p=0,0447). O alfa de Cronbach para os voluntários analisados em um único grupo foi 0,927 e o coeficiente de correlação intraclasse 0,8456. Conclusões: A escala Dispneia-12-Pt apresenta propriedades biométricas aceitáveis e pode ser empregada em pacientes brasileiros com dispneia de diferentes etiologias.
Titre en anglais
Translation and validation of Dyspnoea -12 scale for the Portuguese spoken in Brazil in patients with COPD and pulmonary hypertension
Mots-clés en anglais
COPD
Dyspnea
Pulmonary hypertension
Resumé en anglais
Objective: To translate and to adapt for the Portuguese spoken in Brazil the scale Dyspnoea-12. To obtain validation data, regarding the use of this scale in patients with COPD and pulmonary hypertension (PH). Methods: The English version of the scale Dyspnoea-12 received a formal translation process and the final version was called Dispneia-12-Pt. The latter was applied to 51 COPD patients (33 men; age: 66.4±8.1 years; FEV1: 48.7±17.2 % pred) and 15 subjects with PH from different etiologies (12 women; age: 45.8±12.7 years; systolic pulmonary arterial pressure: 88±33.2 mmHg). The volunteers also answered the Medical Research Council dyspnea scale (MRC), the basal dyspnea index (DBI), the hospital scale of anxiety and depression, the Saint George Respiratory Questionnaire (SGRQ), respiratory functional evaluation and the six minute walk test (6 MWT). Sixty volunteers also answered the Dispneia-12-Pt scale about two weeks after the first evaluation. Results: In the COPD group the Dispneia-12-Br showed significant correlations with the scales MRC (r=0.4641; p=0.0006), BDI (0.515; p<0.0001), SGRQ (r=0.8113; p<0.0001), anxiety (r=0.4714; p=0.0005), depression (0.4139; p=0.0025) and walked distance in the 6 MWT (r=0.3293; p= 0.0255). In the HP group the scale showed significant correlations with the scales MRC (r=0.5774; p=0.0005), SGRQ (r=0.6907; p=0.0044), walked distance in the 6 MWT (0.7193; p=0.0025) and carbon dioxide diffusion capacity (r=0.564; p=0.0447). Cronbach´s alpha calculated for all volunteers evaluated as a whole was 0.927 while the intraclass correlation coefficient was 0.8456. Conclusions: The Dispneia-12-Pt exhibits acceptable biometric properties and may be used as a tool in Brazilian patients with dyspnea of different etiologies.
 
AVERTISSEMENT - Regarde ce document est soumise à votre acceptation des conditions d'utilisation suivantes:
Ce document est uniquement à des fins privées pour la recherche et l'enseignement. Reproduction à des fins commerciales est interdite. Cette droits couvrent l'ensemble des données sur ce document ainsi que son contenu. Toute utilisation ou de copie de ce document, en totalité ou en partie, doit inclure le nom de l'auteur.
AlineAparecidaSimsic.pdf (420.47 Kbytes)
Date de Publication
2017-11-16
 
AVERTISSEMENT: Apprenez ce que sont des œvres dérivées cliquant ici.
Tous droits de la thèse/dissertation appartiennent aux auteurs
CeTI-SC/STI
Bibliothèque Numérique de Thèses et Mémoires de l'USP. Copyright © 2001-2024. Tous droits réservés.