Tesis Doctoral
DOI
https://doi.org/10.11606/T.17.2020.tde-20082020-113301
Documento
Autor
Nombre completo
Gustavo Henrique Vieira de Andrade
Dirección Electrónica
Instituto/Escuela/Facultad
Área de Conocimiento
Fecha de Defensa
Publicación
Ribeirão Preto, 2019
Director
Tribunal
Abud, Daniel Giansante (Presidente)
Garcia, Rodrigo Gobbo
Muglia, Valdair Francisco
Tucci Junior, Silvio
Título en portugués
Exposição à radiação ionizante dos pacientes e operador na embolização das artérias prostáticas para tratamento da hiperplasia benigna
Palabras clave en portugués
Dose absorvida
Embolização terapêutica
Equivalente de dose pessoal
Hiperplasia prostática
Máxima dose na pele
Proteção radiológica
Sintomas do trato urinário inferior
Resumen en portugués
A embolização das artérias prostáticas (EAP) para tratamento dos sintomas obstrutivos da hiperplasia benigna é um procedimento complexo pela variabilidade anatômica, superposição de vasos e estruturas pélvicas, além do fino calibre e tortuosidade destas artérias. Embora venha ganhando cada vez mais aceitação, não tem sido alvo de estudos dosimétricos. Este trabalho apresenta os resultados de exposição à radiação ionizante dos pacientes e do operador em 34 pacientes consecutivos submetidos à EAP no Hospital da Restauração, Recife-PE. Dados epidemiológicos gerais e do procedimento foram obtidos tais como tempo de fluoroscopia, parâmetros de radiação, projeções e número de imagens. A dosimetria dos pacientes foi realizada através da dose máxima na pele (PSD) obtida com filme radiocrômico (Gafchromic XR RV3), pelo produto kerma ar-área (PKA) e do kerma ar no ponto de referência (Ka,r). A dosimetria ocupacional foi realizada com dosímetros termoluminescentes distribuídos em várias regiões do radiologista intervencionista. As primeiras 25 EAPs foram realizadas com protocolo padrão do equipamento. Neste grupo, a média da máxima dose na pele dos pacientes foi de 2,4 Gy, com PKA médio de 450.7 Gy.cm2. A dose efetiva média do médico foi de 17μSv. Após implementação e testes em phantoms do protocolo otimizado de radiação denominado RECiFE (Radiation Exposure Curtailment For Embolization) desenvolvido em parceria e baseado no sistema CARE - Siemens (Combined applications to reduce exposure), foram realizadas 9 EAPs e os resultados dos protocolos foram comparados. Houve redução das doses do operador de aproximadamente 80%. Concluímos que a EAP é um procedimento com elevada exposição dos pacientes e operador e a otimização dos parâmetros é mandatória, questionando-se os protocolos convencionais dos fabricantes.
Título en inglés
Radiation exposure of patients and staff in prostatic artery embolization for benign hyperplasia
Palabras clave en inglés
Absorbed dose
Embolization
Lower urinary tract symptoms
Maximum skin dose
Personal equivalent dose
Prostatic hyperplasia
Radiological protection
Resumen en inglés
Prostatic artery embolization (PAE) for treatment of obstructive symptoms caused by benign hyperplasia is a technically challenging procedure due the complex anatomic variations, superimposed pelvic vessels and structures and thin and tortuous prostatic arteries. Although its increasingly acceptance, very few dosimetry studies have been done. This paper presents the radiation exposure results of patients and operator in 34 consecutive PAEs in Hospital da Restauração, Recife-PE. Demographic and general procedures data were obtained such as fluoroscopy time, irradiation parameters, used projections and number of images. Patient dosimetry comprised the measure of peak skin dose (PSD) with radiochromic films (Gafchromic XR RV3), air kerma-area product (PKA) and reference air kerma (Ka,r). Occupational dosimetry was performed using thermoluminescent dosimeters distributed over various regions of the physician's body. The first 25 PAEs were performed using the standard radiation protocol of the equipment. In this group the mean PSD was 2,4 Gy, and the mean PKA 450,7 Gy.cm2. The operator mean effective dose was 17μSv. After implementation and phantom testing of optimized protocol called RECiFE (Radiation Exposure Curtailment For Embolization) based on Siemens CARE (Combined applications to reduce exposure), we performed 9 PAEs and compared the exposure parameters with standard protocol. A reduction of approximately 80% was obtained in staff doses. Thus, PAE is high exposure procedure for patients and operator. Optimization is mandatory and standard equipment protocol must be examined.
 
ADVERTENCIA - La consulta de este documento queda condicionada a la aceptación de las siguientes condiciones de uso:
Este documento es únicamente para usos privados enmarcados en actividades de investigación y docencia. No se autoriza su reproducción con finalidades de lucro. Esta reserva de derechos afecta tanto los datos del documento como a sus contenidos. En la utilización o cita de partes del documento es obligado indicar el nombre de la persona autora.
Fecha de Publicación
2020-10-19
 
ADVERTENCIA: Aprenda que son los trabajos derivados haciendo clic aquí.
Todos los derechos de la tesis/disertación pertenecen a los autores
CeTI-SC/STI
Biblioteca Digital de Tesis y Disertaciones de la USP. Copyright © 2001-2024. Todos los derechos reservados.