• JoomlaWorks Simple Image Rotator
  • JoomlaWorks Simple Image Rotator
  • JoomlaWorks Simple Image Rotator
  • JoomlaWorks Simple Image Rotator
  • JoomlaWorks Simple Image Rotator
  • JoomlaWorks Simple Image Rotator
  • JoomlaWorks Simple Image Rotator
  • JoomlaWorks Simple Image Rotator
  • JoomlaWorks Simple Image Rotator
  • JoomlaWorks Simple Image Rotator
 
  Bookmark and Share
 
 
Mémoire de Maîtrise
DOI
https://doi.org/10.11606/D.17.2021.tde-11042022-143300
Document
Auteur
Nom complet
Murilo Augusto Duarte Vieira
Unité de l'USP
Domain de Connaissance
Date de Soutenance
Editeur
Ribeirão Preto, 2021
Directeur
Jury
Júnior, Rubens Fazan (Président)
Colombari, Débora Simões de Almeida
Correa, Fernando Morgan de Aguiar
Titre en portugais
Análise da função barorreflexa e parâmetros cardiovasculares avaliados pela cateterização de diferentes artérias em ratos não anestesiados
Mots-clés en portugais
Barorreflexo
Isquemia
Sistema nervoso autônomo
Variabilidade da frequência cardíaca
Resumé en portugais
A medida direta da pressão arterial (PA) pela cateterização oclusiva de artérias periféricas é um procedimento comum em laboratórios de fisiologia cardiovascular. No entanto, fatores como isquemia, inflamação e/ou dor podem comprometer a interpretação de dados coletados, principalmente em animais não anestesiados. No presente estudo, avaliamos parâmetros hemodinâmicos, variabilidade da frequência cardíaca, da pressão arterial e função barorreflexa em ratos com cateterização de diferentes artérias. Foram selecionados registros basais de PA de estudos prévios do laboratório realizados por meio de cateteres implantados na a. femoral (N=10), carótida (N=9) ou por cateterização não oclusiva da aorta abdominal (N=13). Séries de valores de intervalo de pulso (IP) e PA sistólica foram geradas para cada grupo de registros e utilizadas para cálculo de índices de variabilidade desses parâmetros, bem como para avaliação da função barorreflexa pela técnica da sequência e por análise espectral cruzada. Os ratos com cateter na carótida foram taquicardíacos (392±18 bpm) comparados àqueles com cateter na a. femoral (358±11 bpm) ou aorta abdominal (343±10 bpm). A PA sistólica foi maior nos animais com cateter na a. femoral (126±3 mmHg) em relação aos outros grupos (123±3 mmHg, carótida; 113±3 mmHg, aorta abdominal). A variabilidade do IP nos domínios do tempo e frequência, bem como a entropia amostral, foram semelhantes entre os grupos, no entanto, o espectro da PA mostrou um aumento na potência das oscilações de baixa frequência nos animais com cateter na a. femoral (6,9±1,1 mmHg²) em relação aos demais grupos (3,2±0,5 e 2,9±0,5 mmHg²). A análise simbólica dos valores de PA mostrou aumento na incidência dos padrões de 1V (45±2 %) em comparação com os animais cateterizados na aorta (36±2 %). Os animais com cateter na a. femoral apresentaram menor sensibilidade do barorreflexo (0,9±0,06 ms/mmHg) do que aqueles cateterizados através da aorta abdominal (1,3±0,06 ms/mmHg). A análise espectral cruzada mostrou resultados semelhantes à técnica da sequência para avaliação do barorreflexo. Dessa forma, podemos sugerir que a cateterização oclusiva, tanto da a. femoral, como da carótida levam a um desbalanço autonômico com preponderância simpática e a uma disfunção o barorreflexo. Então, é importante considerar o potencial o potencial efeito oclusão arterial na interpretação de dados.
Titre en anglais
Analysis of baroreflex function and heart rate variability measured trough the catheterization of different arteries on unanesthetized rats
Mots-clés en anglais
Autonomic nervous system
Baroreflex
Heart rate variability
Ischemia
Resumé en anglais
Direct measurement of arterial pressure (AP) by occlusive catheterization of peripheral arteries is a common procedure in cardiovascular physiology laboratories. However, factors such as ischemia, inflammation and/or pain can affect the interpretation of collected data, especially in unanesthetized animals. In the present study, we evaluated hemodynamics, heart rate and blood pressure variability, as well as baroreflex function in rats with catheterization of different arteries. Baseline AP recordings from previous studies performed in our laboratory through catheters in femoral artery (N=10), carotid (N=9) or by non-occlusive catheterization of the abdominal aorta (N=13). Series of pulse interval (PI) and systolic AP values were generated for each group of recordings and used to calculate the variability indices of these parameters, as well as to assess the baroreflex function by the sequence technique and by cross-spectral analysis. Rats with catheter in the carotid were tachycardiac (392±18 bpm) compared to those with catheter in femoral artery (358±11 bpm) or abdominal aorta (343±10 bpm). Systolic AP was higher in animals with a catheter into femoral artery (126±3 mmHg) as compared to the other groups (123±3 mmHg, carotid; 113±3 mmHg, abdominal aorta). The variability of PI in the time and frequency domains, as well as the sample entropy, were similar among the groups, however, the AP spectra showed an increased power of low frequency oscillations in animals with catheter into femoral artery (6.9±1.1 mmHg²) as compared to the other groups (3.2±0.5 and 2.9±0.5 mmHg²). Symbolic analysis of BP values showed an increase in the incidence of 1V patterns (45±2 %) compared to animals catheterized in the aorta (36±2 %). Animals with catheters into femoral artery had lower baroreflex sensitivity (0.9±0.06 ms/mmHg) than those catheterized through the abdominal aorta (1.3±0.06 ms/mmHg). Cross spectral analysis showed similar results than the sequence technique. Our study suggests that occlusive catheterization of femoral artery, as well as carotid, lead to an autonomic unbalance (with sympathetic predominance) and baroreflex dysfunction in awake rats. Therefore, it is important to consider the potential effect of arterial occlusion in data interpretation.
 
AVERTISSEMENT - Regarde ce document est soumise à votre acceptation des conditions d'utilisation suivantes:
Ce document est uniquement à des fins privées pour la recherche et l'enseignement. Reproduction à des fins commerciales est interdite. Cette droits couvrent l'ensemble des données sur ce document ainsi que son contenu. Toute utilisation ou de copie de ce document, en totalité ou en partie, doit inclure le nom de l'auteur.
Date de Publication
2022-04-14
 
AVERTISSEMENT: Apprenez ce que sont des œvres dérivées cliquant ici.
Tous droits de la thèse/dissertation appartiennent aux auteurs
CeTI-SC/STI
Bibliothèque Numérique de Thèses et Mémoires de l'USP. Copyright © 2001-2024. Tous droits réservés.