Master's Dissertation
DOI
https://doi.org/10.11606/D.16.2004.tde-29092023-121254
Document
Author
Full name
Rafael Silva Brandão
Institute/School/College
Knowledge Area
Date of Defense
Published
São Paulo, 2004
Supervisor
Committee
Alucci, Marcia Peinado (President)
Assis, Eleonora Sad de
Duarte, Denise Helena Silva
Title in Portuguese
Acesso ao sol e à luz natural: avaliação do impacto de novas edificações no desempenho térmico, luminoso e energético do seu entorno
Keywords in Portuguese
Comforto ambiental
Conforto térmico
Energia solar
Abstract in Portuguese
O objeto desta pesquisa é a relação, na escala urbana, entre as relações geométricas entre duas ou mais edificações e o acesso aos recursos naturais, no caso, a luz e o sol, de modo a otimizar o conforto térmico e luminoso, bem como a eficiência energética nos edifícios urbanos em cidades de médio e grande porte. O objetivo foi desenvolver uma ferramenta que possa ser incorporada à legislação urbana ou aos procedimentos administrativos municipais que permita avaliar o efeito de novas edificações no desempenho térmico e luminoso dos vizinhos, servindo como parâmetro para a determinação de recuos, gabaritos e densidade urbana. Propôs-se seguir um raciocínio dedutivo, gerando uma ferramenta a partir de modelos já existentes. Para isso, o objeto de estudo foi dividido em três partes interdependentes entre si: a fonte, a interface e o uso final da energia. Estabelecer a comparação entre a necessidade de energia solar para iluminação e aquecimento e a sua indesejabilidade como carga térmica constituiu-se no principal desafio. Utilizou-se o consumo energético como variável comum, o que respondeu adequadamente ao fim proposto. Foi possível chegar a um ângulo de obstrução ótimo para cada orientação de fachada de acordo com o uso predominante na área. A iluminação apresentou-se como fator determinante, principalmente quando os edifícios não apresentavam cargas internas altas ou panos de vidro na fachada. O consumo ar condicionado teve peso mais significativo nas edificações com fachadas envidraçadas, sendo o seu impacto aumentado na medida em que se aumenta a carga interna. Deste modo, infere-se que só se justifica a avaliação do impacto da obstrução no desempenho térmico no caso de edificações comerciais. Caso contrário, a abordagem simplificada, levando em conta só a iluminação pode ser suficiente. Conclui-se ainda que é possível utilizar ângulos de obstrução diferentes dependendo do uso e das características predominantes das edificações, sendo possível se atingir altas densidades, preservando o acesso dos vizinhos ao sol e à luz natural.
Title in English
Not available
Keywords in English
Not available
Abstract in English
This paper refers to the geometric relationship among two or more urban buildings and their access to natural resources, mainly daylight and sunlight, so that comfort and energy performance of both may be optimized. The main goal was to develop a tool to assess the impact of new buildings on thermal and lighting performance of neighbors. This could be incorporated to the urban legislation or be used to determine setbacks, height limits and desired urban densities. The tool is to be generated using available models, which may describe the source (sun and daylight), the interface (the city) and the final use of solar energy (buildings passive and pro-active solar systems). In order to compare solar energy needs and undesirable thermal loads, energy consumption was used as common ground, which proved to be an adequate solution to the problem. Obstruction angles were determined for each façade orientation, given a current use for the urban area, commercial or residential. For low internal load buildings with no curtain walls, daylight proved to be the main criterion to determine the angles. Air conditioning was only critical in buildings with a high wall-window ratio, especially in those with high internal loads. This leads to the conclusion that thermal performance evaluation is only justifiable for large commercial buildings. In other cases, a simplified approach may be used, considering only daylight to determine obstruction angles and setbacks. It was also concluded that it is possible to allow different obstruction angles for different urban areas, according to land use and desired densities. Therefore, high-density development is possible still preserving solar and daylight access rights.
 
WARNING - Viewing this document is conditioned on your acceptance of the following terms of use:
This document is only for private use for research and teaching activities. Reproduction for commercial use is forbidden. This rights cover the whole data about this document as well as its contents. Any uses or copies of this document in whole or in part must include the author's name.