• JoomlaWorks Simple Image Rotator
  • JoomlaWorks Simple Image Rotator
  • JoomlaWorks Simple Image Rotator
  • JoomlaWorks Simple Image Rotator
  • JoomlaWorks Simple Image Rotator
  • JoomlaWorks Simple Image Rotator
  • JoomlaWorks Simple Image Rotator
  • JoomlaWorks Simple Image Rotator
  • JoomlaWorks Simple Image Rotator
  • JoomlaWorks Simple Image Rotator
 
  Bookmark and Share
 
 
Thèse de Doctorat
DOI
https://doi.org/10.11606/T.16.2023.tde-11122023-111404
Document
Auteur
Nom complet
Fábio Gallo Junior
Adresse Mail
Unité de l'USP
Domain de Connaissance
Date de Soutenance
Editeur
São Paulo, 2023
Directeur
Jury
Oliveira, Claudia Terezinha de Andrade (Président)
Barossi, Antonio Carlos
França, Ricardo Leopoldo e Silva
Lindenberg Neto, Henrique
Silva, Cátia da Costa e
Titre en portugais
Análise estrutural do patrimônio edificado: contribuição de modelos estruturais analíticos à preservação do edifício Vilanova Artigas
Mots-clés en portugais
Análise estrutural
Concreto armado
Edifício Vilanova Artigas
Patrimônio edificado
Resumé en portugais
Diante de incertezas quanto ao comportamento estrutural do edifício Vilanova Artigas, a pesquisa investiga a hipótese de que, frente às principais intervenções ocorridas, esse se mantém compatível com aquele para o qual foi concebido. A partir de uma abordagem dedutiva de investigação estrutural do patrimônio, elaboraram-se cinco modelos analíticos representativos da estrutura do edifício em diferentes períodos, definidos com base no histórico das principais intervenções a que foi submetido desde a década de 1970. Concluiu-se que, localmente, na cobertura, o incremento de carga implicado nas intervenções conduziu a aumento da ordem de 20% nos esforços internos máximos de flexão e também nas flechas das vigas. Nos pórticos longitudinais, os máximos esforços de flexão não alcançaram variação superior a 5% em relação às condições originais simuladas para a estrutura. Em relação as fundações, as dispostas sob os pilares externos das fachadas longitudinais foram as mais sensíveis às variações de carregamento da cobertura, alcançando cerca de 10% de diferença entre modelos. No que se refere à comparação com as cargas previstas na documentação de projeto estrutural para as fundações, há casos em que foram expressivamente superadas, chegando a incrementos de carregamento da ordem de 70%. Em relação à sensibilidade do edifício frente aos efeitos globais de 2ª ordem, constatou-se ser maior na direção transversal, mas ainda assim desprezível de acordo com o coeficiente z que a avalia, o qual resultou inferior a 1,10 em todos os modelos representativos das intervenções contempladas no trabalho. Por fim, a pesquisa possibilitou detectar vulnerabilidades de ordem estrutural para as quais se recomendam monitoramentos e abordagens complementares de investigação, com vistas a corroborar os resultados alcançados e subsidiar futuros procedimentos de intervenções no edifício.
Titre en anglais
Structural analysis of the built heritage: contribution of structural analytical models to the preservation of the Vilanova Artigas building
Mots-clés en anglais
Built heritage
Reinforced concrete
Structural analysis
Vilanova Artigas Building
Resumé en anglais
Faced with uncertainties regarding the structural behavior of the Vilanova Artigas building, the research investigates the hypothesis that, given the main interventions that have occurred, it remains compatible with the one for which it was conceived. From a deductive approach of structural investigation of the heritage, five representative analytical models of the structure of the building in different periods were elaborated, defined based on the history of the main interventions to which it was submitted since the 1970s. It was concluded that, locally, on the roof, the increase in load involved in the interventions that took place led to an increase of around 20% in the maximum internal bending efforts and also in the beams' maximum displacements. In the longitudinal frames, the maximum bending efforts did not reach a variation greater than 5% in relation to the original conditions simulated for the structure. Regarding the foundations, those arranged under the external pillars of the longitudinal facades were the most sensitive to variations in roof loading, reaching about 10% of difference between models. With regard to the comparison with the loads foreseen in the structural design documentation for the foundations, there are cases in which they were significantly exceeded, reaching loading increments of around 70%. Regarding the sensitivity of the building to 2nd order global effects, it was found to be greater in the transverse direction, but still negligible according to the z coefficient that evaluates it, which resulted in less than 1.10 in all representative models of the interventions contemplated in the work. Finally, the research made it possible to detect structural vulnerabilities for which monitoring and complementary investigation approaches are recommended, in order to corroborating the results achieved and subsidizing future intervention procedures in the building.
 
AVERTISSEMENT - Regarde ce document est soumise à votre acceptation des conditions d'utilisation suivantes:
Ce document est uniquement à des fins privées pour la recherche et l'enseignement. Reproduction à des fins commerciales est interdite. Cette droits couvrent l'ensemble des données sur ce document ainsi que son contenu. Toute utilisation ou de copie de ce document, en totalité ou en partie, doit inclure le nom de l'auteur.
Date de Publication
2023-12-14
 
AVERTISSEMENT: Apprenez ce que sont des œvres dérivées cliquant ici.
Tous droits de la thèse/dissertation appartiennent aux auteurs
CeTI-SC/STI
Bibliothèque Numérique de Thèses et Mémoires de l'USP. Copyright © 2001-2024. Tous droits réservés.