Titre en portugais
Inversão Conjunta 2D de Dados de Caminhamento Elétrico e Caminhamento TDEM Aplicados a Estudos Hidrogeológicos em Taubaté/SP
Mots-clés en portugais
Aquífero Taubaté
Bacia de Taubaté
Caminhamento Elétrico (CE)
Caminhamento Eletromagnético no Domínio do Tempo (CTDEM)
Inversão Conjunta 2D CE/CTDEM
Resumé en portugais
Nesta Pesquisa foi empregada a metodologia de Inversão Conjunta 2D de dados de caminhamento elétrico (CE) e caminhamento eletromagnético no domínio do tempo (CTDEM) num estudo hidrogeológico da Bacia de Taubaté. A área de estudo localiza-se na cidade de Taubaté/SP, onde o Aquífero Taubaté é uma importante fonte alternativa de água frente à recente crise hídrica. O Grupo Taubaté é o principal pacote sedimentar da bacia, sendo formado principalmente por folhelhos, que formam aquicludes, e arenitos, que formam o aquífero. Foram identificados 40 poços de exploração de água subterrânea na cidade, cadastrados no banco de dados do SIAGAS-CPRM, os quais forneceram informações importantes para a interpretação dos resultados. O objetivo principal da pesquisa é caracterizar a estratigrafia geoelétrica da subsuperfície para localizar o contato entre os sedimentos Quaternários e Terciários e mapear o aquífero. Os dados de CE permitem o reconhecimento das camadas mais rasas, da ordem de dezenas de metros, e os dados de CTDEM investigam as camadas mais profundas, numa ordem de centenas de metros, portanto, fornecem informações complementares. Os resultados das inversões conjuntas de CE/CTDEM permitiram mapear as camadas sedimentares mais rasas resistivas até aproximadamente 30 m de profundidade, uma camada sedimentar condutiva intermediária entre 30 m e 50 m de profundidade, e uma camada condutiva referente ao Grupo Taubaté entre 50 m e 300 m de profundidade. O topo do embasamento da bacia foi inferido em ~300 m de profundidade com base nas informações de poços e de geologia da bacia, por outro lado, também é possível que essa interface represente uma variação faciológica do Grupo Taubaté, portanto, mais estudos são necessários.
Titre en anglais
2D Joint Inversion of Electrical Resistivity Tomography (ERT) and Time Domain Electromagnetic (TDEM) Data Applied to a Hydrogeological Study of the Taubaté Basin, São Paulo State, Brazil.
Mots-clés en anglais
2D Joint Inversion ERT/TDEM
2D TDEM
Electrical Resistivity Tomography (ERT)
Taubaté Aquifer
Taubaté Basin
Resumé en anglais
In this research, a 2D Joint Inversion of electrical resistivity tomography (ERT) and time domain electromagnetic (TDEM) data was applied to a hydrogeological study of the Taubaté basin. The study area is in Taubaté city, São Paulo State, Brazil, where the Taubaté aquifer is an important alternative water source due to the recent water crisis. The Taubaté Group is the main sedimentary package of the basin, which is formed mainly by shales, that form aquicludes, and sandstones that form the aquifer. 40 groundwater exploration wells were identified in the city, registered in SIAGAS-CPRM database, which provided important information for the results interpretation. The main objective of this research is to characterize the geoelectrical stratigraphy of the subsurface to locate the contact between the Quaternary and Tertiary sediments and to map the aquifer. The ERT is used for shallow investigations (tens of meters) and the TDEM can reach a great investigation depth (hundreds of meters), therefore, they provide complementary information. The 2D ERT/TDEM joint inversion results permitted to map the shallower resistive layers down to 30 m depth, an intermediate conductive layer between 30 m and 50 m depth, and the Taubate Group between 50 m and 300 m depth, which is very conductive. The top of the basement was inferred at ~300 m depth based on the well information and the basin geology, on the other hand, it is also possible that this interface represents a faciological variation of the Taubaté Group, therefore, more studies are needed.
 
AVERTISSEMENT - Regarde ce document est soumise à votre acceptation des conditions d'utilisation suivantes:
Ce document est uniquement à des fins privées pour la recherche et l'enseignement. Reproduction à des fins commerciales est interdite. Cette droits couvrent l'ensemble des données sur ce document ainsi que son contenu. Toute utilisation ou de copie de ce document, en totalité ou en partie, doit inclure le nom de l'auteur.
Date de Publication
2019-01-22
 
AVERTISSEMENT: Apprenez ce que sont des œvres dérivées cliquant ici.
Tous droits de la thèse/dissertation appartiennent aux auteurs
CeTI-SC/STI
Bibliothèque Numérique de Thèses et Mémoires de l'USP. Copyright © 2001-2024. Tous droits réservés.