Tesis Doctoral
DOI
https://doi.org/10.11606/T.106.2018.tde-21122017-110248
Documento
Autor
Nombre completo
Gilberto Figueiredo Pinto Filho
Dirección Electrónica
Instituto/Escuela/Facultad
Área de Conocimiento
Fecha de Defensa
Publicación
São Paulo, 2017
Director
Tribunal
Zilles, Roberto (Presidente)
Andrade, Adnei Melges de
Moreno, Francisco Martínez
Pinho, João Tavares
Rüther, Ricardo
Título en portugués
Degradação induzida pelo potencial em módulos e instalações fotovoltaicas de c-Si
Palabras clave en portugués
Degradação induzida pelo potencial
Manutenção preditiva
Método de detecção
Sistemas fotovoltaicos conectados à rede
Resumen en portugués
Este trabalho apresenta abordagens para a avaliação do fenômeno da Degradação Induzida pelo Potencial (PID do inglês Potential Induced Degradation) em módulos e instalações fotovoltaicas de c-Si. Nos ensaios em laboratório, a IEC TS 62804-1:2015 foi aplicada e ações adicionais são sugeridas como forma de adaptação da especificação técnica para o acompanhamento da degradação durante o ensaio e para melhor indicar a propensão do equipamento a se recuperar das consequências da aparição de PID. Nos ensaios em campo, avaliou-se a solução convencional do mercado de reverter a degradação através de circuitos anti-PID, além de apresentar a aplicação de técnicas de detecção do fenômeno em sistemas operacionais. A abordagem teórica e os resultados práticos mostram que o procedimento de aferição de tensões individuais de operação é um método útil para detectar PID. Os estudos de caso apresentados indicam que esta metodologia é eficaz inclusive na detecção precoce do fenômeno para diferentes topologias de células fotovoltaicas de c-Si.
Título en inglés
Potential induced degradation on c-Si photovoltaic modules and installations
Palabras clave en inglés
Detection method
Grid-connected photovoltaic systems
Potential induced degradation
Predictive maintenance
Resumen en inglés
This work presents approaches to assess the Potential Induced Degradation (PID) on c-Si photovoltaic modules and installations. The IEC TS 62804-1:2015 was applied to the laboratory tests and some additional actions are suggested. The adaptation of the technical specification aims to monitor the degradation rates during the tests and also to consider the capacity of the photovoltaic modules to recover from the degradation. In the field detection methodologies are presented and anti-PID circuits were also tested. The theoretical approach reveals that individual voltage measurements are useful to detect PID even in its early stage, as can be seen on the case studies presented.
 
ADVERTENCIA - La consulta de este documento queda condicionada a la aceptación de las siguientes condiciones de uso:
Este documento es únicamente para usos privados enmarcados en actividades de investigación y docencia. No se autoriza su reproducción con finalidades de lucro. Esta reserva de derechos afecta tanto los datos del documento como a sus contenidos. En la utilización o cita de partes del documento es obligado indicar el nombre de la persona autora.
Fecha de Publicación
2018-01-30
 
ADVERTENCIA: Aprenda que son los trabajos derivados haciendo clic aquí.
Todos los derechos de la tesis/disertación pertenecen a los autores
CeTI-SC/STI