Mémoire de Maîtrise
DOI
https://doi.org/10.11606/D.106.2017.tde-01032017-170035
Document
Auteur
Nom complet
Mauricio Andrés Rodríguez Cassares
Unité de l'USP
Domain de Connaissance
Date de Soutenance
Editeur
São Paulo, 2016
Directeur
Jury
Zilles, Roberto (Président)
Andrade, Adnei Melges de
Sauaia, Rodrigo Lopes
Trigoso, Federico Bernardino Morante
Titre en portugais
Avaliação operacional de sistemas fotovoltaicos com seguimento solar: sistemas com e sem concentração
Mots-clés en portugais
Energia solar
sistemas de seguimento solar
sistemas fotovoltaicos com concentração
Resumé en portugais
A partir de 2014, o interesse pelas grandes centrais de geração fotovoltaica tem aumentado no Brasil. Visando elevar a produtividade dos sistemas e, com isso, alavancar a competitividade econômica, muitos dos investidores de grandes projetos estão optando pela utilização de sistemas de seguimento solar. Contudo, há pouco conhecimento sobre o real desempenho operacional de sistemas fotovoltaicos com seguimento no país. Este trabalho avalia a operação e o desempenho de sistemas fotovoltaicos com seguimento solar, com e sem concentração, através de dois estudos de caso. No primeiro, foram avaliados e comparados dois sistemas fotovoltaicos com seguimento em dois eixos, um com módulos de concentração e outro com módulos planos, ambos instalados em Ilha Solteira, São Paulo. Já no segundo, realizou-se a avaliação de um sistema fotovoltaico com seguimento de eixo horizontal instalado na Universidade de São Paulo, bem como a comparação deste sistema com um sistema fixo. Para realizar as avaliações nos estudos de caso, foram utilizadas as figuras de mérito produtividade final, YF, rendimento global, PR, e fator de capacidade, FC. No caso dos sistemas de Ilha Solteira, os resultados evidenciam não só que o sistema sem concentração teve um melhor desempenho em relação ao sistema com concentração, como também evidenciam a necessidade de atenção devido às particularidades dos sistemas fotovoltaicos com concentração no Brasil. No caso dos sistemas instalados na Universidade de São Paulo, os resultados mostram que, ao longo de seis meses de operação, o sistema fotovoltaico de eixo horizontal teve um ganho médio de produtividade final de 9% comparado com o sistema fixo.
Titre en anglais
Operational evaluation of photovoltaic systems with solar tracking: systems with and without concentration
Mots-clés en anglais
concentrated photovoltaic systems
Solar energy
solar tracking systems
Resumé en anglais
Since 2014, interest in large-scale photovoltaic power plants has increased in Brazil. Aiming to raise system yield and thereby boost economic competitiveness, many investors are making use of solar tracking systems. However, there is little knowledge on the actual operational performance of photovoltaic systems with solar tracking in the country. This work evaluates the operation and performance of photovoltaic systems with solar tracking capabilities, with and without concentration technology, through two case studies. First, two photovoltaic systems with dual-axis solar tracking, one with concentration modules and the other with flat modules, both installed in Ilha Solteira, São Paulo, are evaluated and compared. Second, the performance of a photovoltaic system with horizontal axis solar tracking installed at the University of São Paulo, São Paulo, is evaluated, followed by a comparison with a fixed photovoltaic system. In order to carry out these assessments, the final yield, YF, the performance ratio, PR, and the capacity factor, FC, were used as figures of merit. Regarding the systems installed in Ilha Solteira, the results not only show that the non-concentrating system performed better than the concentrating system, but also evidences the necessity for attention due to the particularities of the photovoltaic systems with concentration technology in Brazil. As for the systems installed at the University of São Paulo, the results show that the photovoltaic system with horizontal-axis solar tracking had a final average yield 9% higher when compared to the fixed-tilt system.
 
AVERTISSEMENT - Regarde ce document est soumise à votre acceptation des conditions d'utilisation suivantes:
Ce document est uniquement à des fins privées pour la recherche et l'enseignement. Reproduction à des fins commerciales est interdite. Cette droits couvrent l'ensemble des données sur ce document ainsi que son contenu. Toute utilisation ou de copie de ce document, en totalité ou en partie, doit inclure le nom de l'auteur.
Date de Publication
2017-04-19
 
AVERTISSEMENT: Apprenez ce que sont des œvres dérivées cliquant ici.
Tous droits de la thèse/dissertation appartiennent aux auteurs
CeTI-SC/STI
Bibliothèque Numérique de Thèses et Mémoires de l'USP. Copyright © 2001-2024. Tous droits réservés.