Mémoire de Maîtrise
DOI
https://doi.org/10.11606/D.102.2018.tde-12012018-103257
Document
Auteur
Nom complet
María del Pilar Casatejada Gil
Adresse Mail
Unité de l'USP
Domain de Connaissance
Date de Soutenance
Editeur
São Carlos, 2017
Directeur
Jury
Chvatal, Karin Maria Soares (Président)
Cavalcanti, Fernando Antonio de Melo Sá
Franieck, Rosana Maria Caram
Neves, Leticia de Oliveira
Titre en portugais
Simplificações na modelagem de habitações de interesse social no programa de simulação de desempenho térmico EnergyPlus
Mots-clés en portugais
Conforto térmico
Simplificação na modelagem
Simulação computacional
Ventilação natural
Zonas térmicas
Resumé en portugais
Os programas computacionais de simulação do desempenho termoenergético de edificações têm adquirindo cada vez mais importância devido às possibilidades que apresentam para a avaliação dos projetos. No entanto, há dificuldades para o seu uso nas fases iniciais de projeto, por demandarem tempo, técnicos especializados, orçamentos elevados e um projeto detalhado. Atualmente, existem ferramentas computacionais simplificadas, mas que apresentam limitações quanto às possibilidades de uso, não oferecendo resultados precisos como os dos métodos mais complexos. Portanto, este trabalho propõe avaliar as possibilidades de simplificação das zonas térmicas no programa de simulação EnergyPlus, sem comprometer os resultados das simulações. Esta simplificação auxiliaria o uso dessas ferramentas computacionais nas fases iniciais do projeto. O edifício estudado é uma habitação de interesse social (HIS) naturalmente ventilada, térrea e isolada, simulada para três cidades do Brasil (Curitiba, Manaus e São Paulo). Esta HIS é modelada no EnergyPlus de duas formas: como um modelo multizona (MuZ) e como um modelo monozona (MoZ), em que toda a habitação é considerada apenas como uma única zona térmica. O impacto da simplificação das zonas térmicas é avaliado em dois estudos que consideram: 1) vários horários para abertura e fechamento de portas internas, e 2) diferentes geometrias e distribuições internas para os ambientes. Em ambos os estudos, os resultados mostram que a diferença absoluta horária da temperatura entre os modelos MoZs e MuZs é significativamente baixa para todos os casos considerados, estando abaixo de 0,4ºC mais de 50% do tempo. As maiores diferenças encontradas entre os MoZs e MuZs são obtidas nos modelos simulados nos climas mais frios, nos modelos nos quais as portas internas são consideradas fechadas e nos ambientes menores com uma exposição à radiação solar mais reduzida. As diferenças anuais mínimas e máximas da temperatura interna do ar entre os MoZ e MuZ são notadamente elevadas. No entanto, estes valores são observados num dia e uma hora específica, sendo a média anual significativamente baixa para todos os casos.
Titre en anglais
Modeling simplification of social houses in the thermal performance simulation program EnergyPlus
Mots-clés en anglais
Computational simulation
Modeling simplification
Natural ventilation
Thermal comfort
Thermal zones
Resumé en anglais
Building thermal and energy performance simulation programs are gaining more and more importance due to the possibilities they present for a project evaluation. However, there are difficulties for its use in the early stages of the project, because they demand time, specialized technicians, high budgets and a detailed project. Currently, there are simplified computer tools, but they present limits to the possibilities of its use, since they do not offer accurate results as more complex methods. Therefore, this work proposes to evaluate the possibilities of simplification of the thermal zones in EnergyPlus simulation program without compromising the results of the simulations. This simplification would help the computational tools use in the early design of the project. The studied building is a naturally ventilated single-story isolated social house, simulated for three cities of Brazil (Curitiba, Manaus and São Paulo). This building is modeled in two ways: as a multizone model (MuZ) and as a monozone model (MoZ), where the entire floorplan is considered as one thermal zone. The impact of the thermal zones simplification is evaluated in two studies considering: 1) several schedules for internal doors opening and closing, and 2) different building geometries and floorplans. In both studies, the results show that the absolute difference of temperature between the MoZs and MuZs models is significantly low for all of the cases, being below 0.4ºC more than 50% of the time. The maximum differences found between MoZs and MuZs are obtained in models simulated in colder climates, in models where internal doors are considered closed and in smaller rooms with reduced exposure to solar radiation. The minimum and maximum annual differences of the air temperature between the MoZ and MuZ are considerably high. However, these values are observed in a specific day and hour, with the annual average being significantly low for all cases.
 
AVERTISSEMENT - Regarde ce document est soumise à votre acceptation des conditions d'utilisation suivantes:
Ce document est uniquement à des fins privées pour la recherche et l'enseignement. Reproduction à des fins commerciales est interdite. Cette droits couvrent l'ensemble des données sur ce document ainsi que son contenu. Toute utilisation ou de copie de ce document, en totalité ou en partie, doit inclure le nom de l'auteur.
Date de Publication
2018-01-22
 
AVERTISSEMENT: Apprenez ce que sont des œvres dérivées cliquant ici.
Tous droits de la thèse/dissertation appartiennent aux auteurs
CeTI-SC/STI
Bibliothèque Numérique de Thèses et Mémoires de l'USP. Copyright © 2001-2024. Tous droits réservés.