• JoomlaWorks Simple Image Rotator
  • JoomlaWorks Simple Image Rotator
  • JoomlaWorks Simple Image Rotator
  • JoomlaWorks Simple Image Rotator
  • JoomlaWorks Simple Image Rotator
  • JoomlaWorks Simple Image Rotator
  • JoomlaWorks Simple Image Rotator
  • JoomlaWorks Simple Image Rotator
  • JoomlaWorks Simple Image Rotator
  • JoomlaWorks Simple Image Rotator
 
  Bookmark and Share
 
 
Tesis Doctoral
DOI
https://doi.org/10.11606/T.10.2019.tde-25092019-124137
Documento
Autor
Nombre completo
Carina Outi Baroni
Dirección Electrónica
Instituto/Escuela/Facultad
Área de Conocimiento
Fecha de Defensa
Publicación
São Paulo, 2019
Director
Tribunal
Pinto, Ana Carolina Brandão de Campos Fonseca (Presidente)
Ghirelli, Carolina de Oliveira
Maiorka, Paulo César
Muramoto, Caterina
Ribas, Laila Massad
Título en portugués
Protocolos de angiotomografia computadorizada post mortem em cães
Palabras clave en portugués
Angiografia
Cães
Necropsia
Tomografia Computadorizada
Resumen en portugués
A introdução de radiografias no auxílio à necropsia data de 1898. Atualmente, modalidades de imagem como a tomografia computadorizada e a ressonância magnética post mortem estão sendo empregadas para complementar a necropsia. Os estudos em medicina veterinária sobre a tomografia e angiotomografia computadorizada post mortem estão no início, mas já mostraram o quanto são valiosos para o diagnóstico da causa de óbitos de cães e gatos. Esta tese teve por finalidade elaborar protocolos de angiotomografia computadorizada post mortem em cães, tendo sido dividida em duas partes. Na primeira, objetivou-se descrever a técnica por via inguinal e por via cervical para realização da ATCPM em cães conservados por congelamento. Na segunda, comparar dois diferentes diluentes da mistura com contraste iodado em dois grupos de cadáveres de cães com distintos tempos de óbito na realização de ATCPM. Para tanto foram realizadas ATCPM em um total de 4 cadáveres no primeiro estudo e 8, no segundo, sendo que no primeiro estudo os cadáveres foram congelados até duas horas do óbito e no segundo, a ATCPM foi feita após 2 horas do óbito em um grupo e entre 12h a 16h no segundo grupo, um com diluente PEG e outro com diluente óleo. Os resultados obtidos permitiram concluir que as duas vias de acesso para a realização da ATCPM em cadáveres de cães conservados por congelamento são exequíveis. A via cervical demonstrou ser mais indicada para avalição da cabeça, ao passo que, para avaliação do abdômen, a via de acesso femoral seria de primeira escolha. E que a TCPM e ATCPM, em um tempo de óbito de até 16h, podem ser realizadas sem que haja comprometimento das condições técnicas para realização dos exames e com obtenção de imagens de qualidade para a interpretação. A mistura PEG e contraste iodado hidrossolúvel, no volume testado e em cadáveres com diferentes tempos de óbito, pôde ser utilizada na avaliação do sistema vascular de cadáveres de cães.
Título en inglés
Protocols of CT angiography post-mortem in dogs
Palabras clave en inglés
Angiography
Computed Tomography
Dogs
Necrospy
Resumen en inglés
The introduction of X-rays in the support of necropsy was initiated in 1898. Nowadays, imaging modalities, such as computed tomography and magnetic resonance post mortem, are being used to complement the necropsy. Studies in veterinary medicine about virtual necropsy are at the beginning, but have already shown how valuable they are for diagnosing the cause of deaths of dogs and cats. The aim of this thesis was to develop protocols of post mortem computed tomography angiography in dogs and in order of that it was divided in two parts. In the first, the objective was to describe the inguinal versus cervical approach for the PMCTA in dogs preserved by freezing. In the second part, the aim was to compare two different diluents of the iodine contrast mixture in two groups of dogs differing in the time of death. Thus, PMCTA was performed in a total of four thawed cadavers, in the first study, and in eight cadavers, with two or 12-16 hours after death, in the second one. The results allowed to the conclusion that both approaches, inguinal and cervical were achievable. The cervical approach showed to be more indicated for the head evaluation and the femoral approach was better for the evaluation of the abdominal organs. Additionally the PMCT and PMCTA in cadavers of up to 16 hours after death can be performed without any compromise of the technical conditions and with acquisition of good quality images for the adequate interpretation. The PEG and iodine water soluble contrast mixture, considering the tested volume in different times of death, could be used in the vascular system evaluation in dog cadavers.
 
ADVERTENCIA - La consulta de este documento queda condicionada a la aceptación de las siguientes condiciones de uso:
Este documento es únicamente para usos privados enmarcados en actividades de investigación y docencia. No se autoriza su reproducción con finalidades de lucro. Esta reserva de derechos afecta tanto los datos del documento como a sus contenidos. En la utilización o cita de partes del documento es obligado indicar el nombre de la persona autora.
Fecha de Publicación
2019-10-18
 
ADVERTENCIA: Aprenda que son los trabajos derivados haciendo clic aquí.
Todos los derechos de la tesis/disertación pertenecen a los autores
CeTI-SC/STI
Biblioteca Digital de Tesis y Disertaciones de la USP. Copyright © 2001-2024. Todos los derechos reservados.