• JoomlaWorks Simple Image Rotator
  • JoomlaWorks Simple Image Rotator
  • JoomlaWorks Simple Image Rotator
  • JoomlaWorks Simple Image Rotator
  • JoomlaWorks Simple Image Rotator
  • JoomlaWorks Simple Image Rotator
  • JoomlaWorks Simple Image Rotator
  • JoomlaWorks Simple Image Rotator
  • JoomlaWorks Simple Image Rotator
  • JoomlaWorks Simple Image Rotator
 
  Bookmark and Share
 
 
Tesis Doctoral
DOI
https://doi.org/10.11606/T.10.2022.tde-17112022-162345
Documento
Autor
Nombre completo
Tatiana Assunção de Moraes
Dirección Electrónica
Instituto/Escuela/Facultad
Área de Conocimiento
Fecha de Defensa
Publicación
São Paulo, 2022
Director
Tribunal
Safatle, Angélica de Mendonça Vaz (Presidente)
Bolzan, Aline Adriana
Ejzenbaum, Fabio
Munhoz, Paula Yuri Sacai
Watanabe, Sung Eun Song
Título en portugués
Mensuração da acuidade visual de cães da raça Cavalier King Charles Spaniel pelo potencial visual evocado de varredura (PVEV)
Palabras clave en portugués
Acuidade visual de grades
Eletrofisiologia
Maturação visual
Visão
Resumen en portugués
A avaliação da visão é parte fundamental do exame oftálmico em humanos. Nos seres não verbais, como bebês e crianças em idade pré-verbal, são necessárias técnicas objetivas de mensuração da acuidade visual de grades. Entre as técnicas eletrofisiológicas, o Potencial Visual Evocado de Varredura (PVEV) tem se mostrado a mais eficaz. Na Medicina Veterinária ainda há poucos trabalhos relacionados ao tema, tanto referentes à padronização da técnica quanto aos valores de referência baseados na idade. Sabe-se que cada raça apresenta particularidades anatômicas que influenciam, de forma determinante, na acuidade visual. Assim, objetivou-se, no presente trabalho determinar padrões de acuidade visual em cães da raça Cavalier King Charles Spaniel (CKCS) em diferentes faixas etárias, bem como determinar o momento da maturação da via visual na raça. Foram avaliados 50 cães da raça CKCS divididos em cinco grupos, contendo 10 animais cada, baseando-se na idade: G1 (20 dias), G2 (30 dias), G3 (45 dias), G4 (90 dias), G5 (entre 1 e 2 anos de idade). Utilizou-se o sistema eletrodiagnóstico Roland RETIport System para obtenção das respostas obtidas em ciclos por grau (cpg), equivalente Snellen, decimal e Log-MAR. A análise estatística foi realizada por meio do teste de Kruskal-Wallis, seguido do teste de Dunn, quando necessário. Para isso, utilizou-se o software estatístico Prism 5 for Windows (GraphPad Software). As medianas dos grupos (G1 ao G5) foram, respectivamente, em cpg, 1,250; 1,750; 3,775; 4,000 e 4,135. Foi observada diferença estatística entre os grupos G1 e G3 e G2 e G3, diferentemente dos grupos G3, G4 e G5, que não apresentaram diferença estatística, sugerindo um platô dos valores de acuidade. Com base nos resultados, a maturidade da via visual foi obtida entre 30 e 45 dias de vida, no grupo experimental avaliado.
Título en inglés
Visual acuity measurement by Sweep-Visual Evoked Potential (S-VEP) in Cavalier King Charles Spaniel dogs
Palabras clave en inglés
Electrophysiology
Grating visual acuity
Vision
Vision maturation
Resumen en inglés
Visual evaluation plays an essential role in the ophthalmic examination in human beings. Some objective techniques are required to achieve gratin visual acuity (VA) in non verbal people, like babies or infants in pre-verbal ages. The Sweep-Visual Evoked Potential (S-VEP) is suggested to be the most feasible electrophysiologic technique to measure visual acuity. In Veterinary Medicine, researches regarding S-VEP standadization and VA values according to age are still scarce. The anatomical peculiarities of each breed directly influence in visual acuity. Thus, the aim of this study was to determine standard values of visual acuity in Cavalier King Charles Spaniel (CKCS) dogs in different ages and to define the moment of visual maturation in this breed. 50 CKCS dogs were selected and divides into five groups by age criteria: G1 (20 days of age), G2 (30 days), G3 (45 days), G4 (90 days), G5 (1 to 2 years old). The S-VEP was performed by Roland RETIport system electrodiagnostic device and the VA values were obtained in cicles per degree (cpd), Snellen Equivalent, decimal and LogMAR. Statstical analysis was based on Kruskal-Wallis test, followed by Dunn test, whenever it was required, using the statistical software Prism 5 for Windows (GraphPad Software). The median of the groups (from G1 to G5) were respectly 1,250; 1,750; 3,775; 4,000 e 4,135cpg. A statistical difference was observed between G1 x G3, and G2 x G3, unlike G3 x G4 x G5, that didn′t show differences between these three older groups, suggesting a plateau of VA values. Based on the results, the visual maturity of the subjects studied was achieved by 30 and 45 days of life.
 
ADVERTENCIA - La consulta de este documento queda condicionada a la aceptación de las siguientes condiciones de uso:
Este documento es únicamente para usos privados enmarcados en actividades de investigación y docencia. No se autoriza su reproducción con finalidades de lucro. Esta reserva de derechos afecta tanto los datos del documento como a sus contenidos. En la utilización o cita de partes del documento es obligado indicar el nombre de la persona autora.
Fecha de Publicación
2023-01-03
 
ADVERTENCIA: Aprenda que son los trabajos derivados haciendo clic aquí.
Todos los derechos de la tesis/disertación pertenecen a los autores
CeTI-SC/STI
Biblioteca Digital de Tesis y Disertaciones de la USP. Copyright © 2001-2024. Todos los derechos reservados.