• JoomlaWorks Simple Image Rotator
  • JoomlaWorks Simple Image Rotator
  • JoomlaWorks Simple Image Rotator
  • JoomlaWorks Simple Image Rotator
  • JoomlaWorks Simple Image Rotator
  • JoomlaWorks Simple Image Rotator
  • JoomlaWorks Simple Image Rotator
  • JoomlaWorks Simple Image Rotator
  • JoomlaWorks Simple Image Rotator
  • JoomlaWorks Simple Image Rotator
 
  Bookmark and Share
 
 
Mémoire de Maîtrise
DOI
https://doi.org/10.11606/D.10.2023.tde-16062023-094841
Document
Auteur
Nom complet
Isabela Espinela Perez
Adresse Mail
Unité de l'USP
Domain de Connaissance
Date de Soutenance
Editeur
São Paulo, 2023
Directeur
Jury
Safatle, Angélica de Mendonça Vaz (Président)
Ejzenbaum, Fabio
Munhoz, Paula Yuri Sacai
Titre en portugais
Mensuração da acuidade visual de resolução em grades em cães da raça Pastor Belga de Malinois pelo Potencial Visual Evocado de Varredura (PVEV)
Mots-clés en portugais
Acuidade visual
Cães
Pastor Belga de Malinois
Potencial visual evocado de varredura
Resumé en portugais
O Potencial Visual Evocado de Varredura (PVEV), considerado um teste eletrofisiológico objetivo, que independe de informações do paciente para estabelecer resultados, tem se mostrado eficaz para mensurar a acuidade visual em seres não verbais na Medicina Veterinária. Ainda existem poucos trabalhos relacionados ao tema, tanto referente aos valores de referência de acordo com a raça e a idade quanto à padronização da técnica. Assim, no presente estudo, objetivou-se determinar a acuidade visual de resolução em grades por meio do exame de Potencial Visual Evocado de Varredura, em cães dolicocefálicos da raça Pastor Belga de Malinois, adultos, a fim de contribuir na padronização de valores de referência para a raça. Foram avaliados 12 cães da raça Pastor Belga de Malinois e, devido ao comportamento agitado e/ou agressivo, outros 12 foram excluídos. Utilizou-se o sistema eletrodiagnóstico Roland RETIport System para obtenção das respostas do PVEV, obtidas em ciclos por grau (cpg), equivalente Snellen e Log-MAR. Foi realizado uma análise estatística descritiva da refração, da biometria ocular e do Potencial Visual Evocado de Varredura, utilizando o software Prism 8.0.1 (GraphPad). O valor da média e do desvio padrão da acuidade visual em ciclos por grau e na escala de Snellen foram 9,5 ± 1,312 e 20/64 ± 8,47, respectivamente. Do total de olhos avaliados, 83,3% eram emétropes, 16,7% hipermétropes de baixo grau (+ 1,0D) e 2 olhos apresentaram astigmatismo. A refração média e o desvio padrão obtidos foram de 0,22±0,4012 D, para o olho direito, e de 0,31±0,3697 D para o olho esquerdo. Com base nos resultados, o PVEV possui aplicabilidade para a mensuração de acuidade visual em cães sem uso de contenção química, porém, o comportamento é uma limitação significativa para a realização do exame.
Titre en anglais
Visual acuity of resolution in grids measurement by Sweep- Visual Evoked Potential (S-VEP) in Belgian Shepherd Malinois dogs
Mots-clés en anglais
Belgian Shepherd Malinois
Dogs
Sweep-Visual Evoked Potential
Visual acuity
Resumé en anglais
The Sweep-Visual Evoked Potential (S-VEP), considered an objective electrophysiologic test, which does not depend on patient information to establish results, has been shown to be effective in visual acuity measurement in non-verbal beings in Veterinary Medicine. There are still few works related to the subject, both regarding the reference values according to race and age and the standardization of the technique. Thus, in the present study, the objective was to determine the visual acuity of resolution in grids by means of the Sweep-Visual Evoked Potential (S-VEP) exam, in dolichocephalic dogs of the Belgian Shepherd Malinois breed, adults, in order to contribute to the standardization of reference values for the race. Twelve Belgian Malinois Shepherd dogs were evaluated and, due to agitated and/or aggressive behavior, another 12 were excluded. The Roland RETIport System electrodiagnostic system was used to obtain S-VEP responses, obtained in cycles per degree (cpg), Snellen equivalent and Log-MAR. A descriptive statistical analysis of refraction, ocular biometry and the Sweep-Visual Evoked Potential was carried out using the Prism 8.0.1 software (GraphPad). The mean and standard deviation values for visual acuity in cycles per degree and on the Snellen scale were 9,5±1,312 and 20/64±8.47, respectively. Of the total number of eyes assessed, 83.3% were emmetropic, 16.7% were low-grade hyperopic (+ 1.0D) and 2 eyes had astigmatism. The mean refraction and standard deviation obtained were 0.22±0.4012D for the right eye and 0.31±0.3697D for the left eye. Based on the results, the S-VEP has applicability for measuring visual acuity in dogs without the use of chemical restraint, however, behavior is a significant limitation for performing the test.
 
AVERTISSEMENT - Regarde ce document est soumise à votre acceptation des conditions d'utilisation suivantes:
Ce document est uniquement à des fins privées pour la recherche et l'enseignement. Reproduction à des fins commerciales est interdite. Cette droits couvrent l'ensemble des données sur ce document ainsi que son contenu. Toute utilisation ou de copie de ce document, en totalité ou en partie, doit inclure le nom de l'auteur.
Il ya retenu fichier en raison d'exigences (publication de données, des brevets ou droits).
Date de Libération
2025-10-09
Date de Publication
2023-10-11
 
AVERTISSEMENT: Apprenez ce que sont des œvres dérivées cliquant ici.
Tous droits de la thèse/dissertation appartiennent aux auteurs
CeTI-SC/STI
Bibliothèque Numérique de Thèses et Mémoires de l'USP. Copyright © 2001-2024. Tous droits réservés.