• JoomlaWorks Simple Image Rotator
  • JoomlaWorks Simple Image Rotator
  • JoomlaWorks Simple Image Rotator
  • JoomlaWorks Simple Image Rotator
  • JoomlaWorks Simple Image Rotator
  • JoomlaWorks Simple Image Rotator
  • JoomlaWorks Simple Image Rotator
  • JoomlaWorks Simple Image Rotator
  • JoomlaWorks Simple Image Rotator
  • JoomlaWorks Simple Image Rotator
 
  Bookmark and Share
 
 
Dissertação de Mestrado
DOI
https://doi.org/10.11606/D.10.2022.tde-02022023-113403
Documento
Autor
Nome completo
Carla Rodriguez Paes
E-mail
Unidade da USP
Área do Conhecimento
Data de Defesa
Imprenta
São Paulo, 2022
Orientador
Banca examinadora
Safatle, Angélica de Mendonça Vaz (Presidente)
Munhoz, Paula Yuri Sacai
Watanabe, Sung Eun Song
Título em português
Avaliação morfofuncional da retina em arara-canindé (Ara ararauna) por eletrorretinografia de campo total e tomografia de coerência óptica
Palavras-chave em português
Arara
ERG
OCT
Segmento posterior
Visão
Resumo em português
A oftalmologia veterinária em aves cresce a cada dia, tanto pela conscientização na conservação, proteção e cuidados das espécies, como também pelo aumento desses animais como pet. O sistema visual desses animais é extremamente especializado e varia de acordo com o estilo de vida, ambiente e principais atividades. Vale salientar que o exame oftalmológico das aves pode ser prejudicado pelo tamanho diminuto dos olhos, dificultando principalmente, a avaliação do segmento posterior. Assim sendo, com o intuito de avaliar fisiologicamente e morfologicamente, estruturas tais como a retina, coroide, pecten, pode-se utilizar exames complementares especializados como eletrorretinografia de campo total (ERG) e tomografia de coerência óptica (OCT). O ERG é um exame pouco invasivo que define a função retiniana, utilizado para avaliação de doenças que cursam com diminuição de visão ou cegueira. É comum a indicação deste exame para cães que serão submetidos à cirurgia de catarata. A OCT é um exame de alta resolução, pouco invasivo e de não contato na maioria dos aparelhos, para avaliação de alterações morfológicas do segmento anterior e posterior, utilizado na medicina, principalmente, por especialistas em vítreo e retina. Com o OCT é possível realizar avaliação qualitativa e quantitativa das estruturas oculares com alta confiabilidade. Na oftalmologia veterinária este exame tem ganhado espaço para avaliar várias espécies, determinando valores de normalidade e detectando doenças oculares. O projeto foi aprovado pela Comissão de Ética no Uso de Animais da Faculdade de Medicina Veterinária e Zootecnia da Universidade de São Paulo - PROTOCOLO No 8241140819. Realizamos os exames de ERG e OCT, nesta ordem, para avaliação da função e da morfologia da retina de 16 araras-canindé (Ara ararauna), adultas, sem idade definida e de ambos os sexos, provenientes do Mantenedor de Fauna Silvestres Fazenda Itaoca (Indaiatuba-SP). Os animais foram submetidos à contenção farmacológica, realizada por sedação com maleato de midazolan (1mg/kg) (Dormire® ) e cloridrato de cetamina 10% (15mg/kg) (Cetamin® ). A midríase medicamentosa foi promovida pela instilação tópica ocular de 1 gota de brometo de rocurônio (10mg/kg) (ROCURON® ) em 3 momentos consecutivos com intervalo de 15 minutos. O ERG de campo total foi realizado após adaptação de 20 minutos ao escuro, dando início a fase escotópica, para avaliação das respostas de bastonetes (-25dB), a máxima resposta (0dB), bright flash (10dB) e os potenciais oscilatórios. Após 10 minutos de adaptação ao claro, para início da fase fotópica, seguimos com a avaliação das respostas de cones (0dB) e flicker (30Hz). Foi obtida a amplitude (µ V) e o tempo de culminação da onda b (ms) das respostas citadas. A OCT foi realizada com os animais devidamente posicionados, com os olhos abertos com auxílio de fitas colantes próximas as rimas palpebrais. Imagens obtidas pelo protocolo linear foram analisadas e selecionadas para mensuração manual, feita no centro da retina, na área entre o pecten e a fóvea, precisamente 2mm desta, das seguintes estruturas: retina total (RT), retina neurossensorial (RN) e complexo de células ganglionares (CCG). Foi realizado análise estatística descritiva com o software Prism 8.0.1 (GraphPad). Para o exame de ERG obtivemos média ± DP das amplitudes das respostas escotópicas: respostas de bastonetes 26.51µV ± 10,70, máxima resposta 197,10µV ± 70,33, bright flash 192,30µV ± 69,98 e potenciais oscilatórios 192,90µV ± 56,86; e respostas fotópicas: respostas de cones 205,60µV ± 50,05 e flicker 30Hz de 48,74µV ± 14,63. As mesmas medidas foram feitas para obter a média ± DP para o tempo de culminação da onda b, sendo obtidas as respostas de: bastonetes 39,18ms ± 11,19, máxima resposta 30,44ms ± 5,11, bright flash 26,71ms ± 5,55, seguidos pelos cones 24,71ms ± 1,099 e flicker de 57,14ms ± 0,9893. Para o exame de OCT, obtive-se a média ± DP das mensurações da RT, RN e CCG, do olho direito e olho esquerdo separadamente. Para o olho direito obtivemos: RT=300,40µm ± 13,94, RN=249,70µm ± 12,66 e CCG=127,80 µ m ± 7,80. E para o olho esquerdo: RT=297,30µm ± 10,75, RN=244,60µm ± 11,81 e CCG=123,40µm ± 7,57. O experimento teve como finalidade, estabelecer o padrão de normalidade, para os exames de ERG E OCT, para a espécie estudada.
Título em inglês
Morphofunctional evaluation of the retina in blue-and-yellow macaw (Ara Ararauna) by full-field electroretinography and optical coherence tomography
Palavras-chave em inglês
ERG
Macaw
OCT
Posterior segment
Vision
Resumo em inglês
Veterinary ophthalmology in birds grows every day, both for the awareness of the conservation, protection and care of the species, as well as for the increase of these animals as pets. The visual system of these animals is extremely specialized and varies according to lifestyle, environment and main activities. It is worth mentioning that the ophthalmological examination of birds can be impaired by the small size of the eyes, mainly making it difficult to evaluate the posterior segment. Therefore, in order to evaluated physiologically and morphologically specific structures such as the retina, choroid and pecten, specialized complementary exams such as full-field electroretinography (ERG) and optical coherence tomography (OCT) can be used. The ERG is a minimally invasive test that defines a retinal function, used to evaluate diseases that progress with increased vision or blindness. It is common to indicate this exam for dogs that will be operated for cataract. The OCT is an important high- resolution exam, non-invasive and non-contact, for analysis changes in anterior and posterior morphological, in medicine mainly by specialists in vitreous and retina. With OCT it is possible to qualitatively perform and define ocular structures with high reliability. In veterinary ophthalmology this exam has gained space to evaluate several species, determining normal values and detecting eye diseases. The project was approved by the Ethics Committee on the Use of Animals of the Faculty of Veterinary Medicine and Zootechnics of the University of São Paulo - PROTOCOL No 8241140819. We performed the ERG and OCT exams, in that order, to evaluate the function and morphology of the retina of 16 blue-and-yellow macaws (Ara ararauna), adults, of no defined age and of both sexes, from the Fazenda Itaoca (Indaiatuba- SP). The animals were submitted to pharmacological containment, performed by sedation with midazolam maleate (1mg/kg) (Dormire® ) and 10% ketamine hydrochloride (15mg/kg) (Cetamin® ). Drug mydriasis was promoted by topical ocular instillation of 1 drop of rocuronium bromide (10mg/kg) (ROCURON® ) in 3 consecutives moments with an interval of 15 minutes. The full-field ERG was performed after 20 minutes of dark adaptation, starting the scotopic phase, to evaluate the rod responses (-25dB), the maximum response (0dB), bright flash (10dB) and the oscillatory potentials. After 10 minutes of adaptation to the light, for the beginning of the photopic phase, we continued with the evaluation of the cone response (0dB) and flicker (30Hz). Amplitude (µV) and culmination time (ms) of responses were obtained. The OCT was performed with the animals properly positioned with their eyes open with the aid of sticky tapes close to the eyelid rims. Images obtained by the linear protocol were analyzed and selected for manual measurement, in the center of the retina, in the area between the pecten and the fovea, precisely 2mm from it, of the following structures: total retina (RT), sensorineural retina (RN), complex of ganglion cells (GCC). Descriptive statistical analysis was performed using Prism 8.0.1 software (GraphPad). For the ERG exam, we obtained mean±SD of the scotopic response amplitudes: rods response 26,51µV±10,70, maximum response 197,10µV±70,33, bright flash 192,30µV±69,98 and oscillatory potentials 192,90µV±56,86; and photopic responses: cones response 205,60µV±50,05 and flicker of 48,74µV±14,63. The same was done to obtain the mean±SD for the culmination time, obtaining the responses of: rods 39,18ms±11,19, maximum response 30,44ms±5,11, bright flash 26,71ms±5,55 , followed by cones 24,71ms±1,099 and flicker of 57,14ms±0,9893. For the OCT exam, the mean±SD of the RT, NB and CCG measurements of the right eye and left eye were obtained separately. For the right eye we obtained: RT=300,40µm±13,94, RN=249,70µm±12,66 and CCG=127,80µm±7,80. And for the left eye: RT=297,30µm±10,75, RN=244,60µm±11,81 and CCG=12,40µm±7,57. The experiment aimed to establish the normality pattern, for the ERG and OCT exams, for the species studied.
 
AVISO - A consulta a este documento fica condicionada na aceitação das seguintes condições de uso:
Este trabalho é somente para uso privado de atividades de pesquisa e ensino. Não é autorizada sua reprodução para quaisquer fins lucrativos. Esta reserva de direitos abrange a todos os dados do documento bem como seu conteúdo. Na utilização ou citação de partes do documento é obrigatório mencionar nome da pessoa autora do trabalho.
Há arquivos retidos devido a solicitação (publicação de dados, patentes ou diretos autorais).
Data de Liberação
2025-10-09
Data de Publicação
2023-10-11
 
AVISO: Saiba o que são os trabalhos decorrentes clicando aqui.
Todos os direitos da tese/dissertação são de seus autores
CeTI-SC/STI
Biblioteca Digital de Teses e Dissertações da USP. Copyright © 2001-2024. Todos os direitos reservados.