• JoomlaWorks Simple Image Rotator
  • JoomlaWorks Simple Image Rotator
  • JoomlaWorks Simple Image Rotator
  • JoomlaWorks Simple Image Rotator
  • JoomlaWorks Simple Image Rotator
  • JoomlaWorks Simple Image Rotator
  • JoomlaWorks Simple Image Rotator
  • JoomlaWorks Simple Image Rotator
  • JoomlaWorks Simple Image Rotator
  • JoomlaWorks Simple Image Rotator
 
  Bookmark and Share
 
 
Thèse de Doctorat
DOI
https://doi.org/10.11606/T.10.2016.tde-26092016-103616
Document
Auteur
Nom complet
Nara Thiers Cacciatori Galleti Bernardes
Adresse Mail
Unité de l'USP
Domain de Connaissance
Date de Soutenance
Editeur
São Paulo, 2016
Directeur
Jury
Gregori, Fabio (Président)
Jerez, José Antonio
Labruna, Marcelo Bahia
Okuda, Liria Hiromi
Pituco, Edviges Maristela
Titre en portugais
Desenvolvimento PCR em Tempo-Real em sistema TaqMan® para detecção de rotavírus em amostras clínicas de bovinos
Mots-clés en portugais
Diagnóstico
Diarreias
PCR em Tempo Real
Rotavírus
Resumé en portugais
A diarréia neonatal é o principal problema sanitário que acomete os bezerros nas primeiras semanas de vida, causando grandes prejuízos devido à morbidade, mortalidade, custos com tratamento e atraso no desenvolvimento. Os rotavírus são os mais importantes agentes virais causadores de gastroenterites em crianças e diarreia em diferentes espécies animais. Além do seu impacto econômico na produção animal, os bovinos podem atuar como reservatórios da diversidade genética e antigênica para humanos. Assim, o diagnóstico deste agente é fundamental para o desenvolvimento de medidas profiláticas mais especificas visando o seu controle. O objetivo deste trabalho foi desenvolver um método de PCR em Tempo Real para a detecção de rotavírus bovinos em sistema Taqman® tendo como alvo, a proteína não-estrutural 5 (NSP5). Para isso, 113 amostras de fezes bovinas foram coletadas de reabanhos do estado de São Paulo, e previamente testadas por PCR convencional. Para a padronização da PCR em Tempo Real, a estirpe padrão foi clonada, gerando um plasmídeo com 3x1010 cópias/reação. Como controle exógeno foi utilizado β-actina. O limite de detecção foi determinado por diluições seriadas na base 10, detectando até 6x101 cópias/µl. A curva padrão da PCR em Temo Real para a detecção do segmento codificador da proteína NSP5 teve como resultados, uma eficiência de 100,47%; com slope igual a -3,18 e R2 de 1,0. De um total de 113 amostras testadas pela PCR convencional 63 delas (55,7%) foram consideradas positivas para rotavírus. Dessas mesmas amostras testadas, 5 não amplificaram para β-actina e não foram incluídas nas análises posteriores. Para a PCR em Tempo Real o limite de detecção foi considerado o valor de 6x101 cópias/reação, sendo definido o ponto de corte o ciclo (Ct) de número 36 para o teste com a amostra viral a partir do DNA ligado em vetor plasmidial. Considerando-se o ponto de corte de 60 (6x101) cópias/reação, das 108 amostras testadas, 63 (58,3%) foram consideradas positivas ao teste. O valor de concordância obtido através do teste Kappa, a um intervalo de confiança de 95%, a partir dos resultados gerados entre os testes de PCR convencional e PCR em foi de 0.279 (baixa concordância). Os resultados obtidos nesse estudo demonstrou que o teste foi eficiente podendo ser utilizado para um diagnóstico rápido e eficiente do rotavirus do grupo A, aumentando assim o repertório dos testes já estabelecidos
Titre en anglais
Development PCR Real-Time Taqman® system for rotavirus detection in clinical samples of cattle
Mots-clés en anglais
Diagnosis
Diarrhoea
Real-Time PCR
Rotavirus
Resumé en anglais
Neonatal diarrhea is the main health problem affecting the calves in the first weeks of life, causing major losses due to morbidity, mortality, treatment costs and delayed development. Rotaviruses are the most important causative agents of viral gastroenteritis in children and in different animal species. In addition to its economic impact on livestock, cattle can act as reservoirs for genetic and antigenic diversity for human samples. Therefore, the diagnosis of this agent is critical to the development of more specific preventive measures for their control. The objective of this work is to develop a method of PCR for rotavirus detection in cattle using TaqMan® system targeting the 5 nonstructural protein (NSP5). For this, 113 samples of cattle feces were collected from farms of São Paulo, and previously tested by convencional PCR. To PCR standardization, the standard sample was cloned, generating plasmid 3x1010 copies/reaction. The β-actin was usede as exogenous control. The limit of detection was determined by serial dilutions, to detect 6 x101 copies/µl. The standard curve of PCR to encoding segment detection NSP5 protein had as a result, an efficiency of 108.5%; with slope equal to -3.18 and R2 equal 1.. From a total of 113 samples tested by conventional PCR 63 (55.7%) were positive for rotavirus. From these samples 5 not amplifyed for β-actin gene and were not included in subsequent analyzes. For detection limit of Real-Time PCR was considered the amount of 6x101 copies / reaction, the cut-off being defined cycle (Ct) number 36 to the test with a viral sample from the DNA ligated into plasmid vector. Considering the cut-off 60 (6x101) copies/reaction of the 108 samples tested, 63 (58.3%) were positive to the test. The correlation value obtained by the Kappa test, at a 95% confidence interval, based on results generated between the conventional and PCR testing PCR was 0.279 (low agreement). The results of this study demonstrated that the probe can be efficiently used for a fast and efficient diagnosis of rotavirus of group A, thereby enhancing the repertoire of the established tests
 
AVERTISSEMENT - Regarde ce document est soumise à votre acceptation des conditions d'utilisation suivantes:
Ce document est uniquement à des fins privées pour la recherche et l'enseignement. Reproduction à des fins commerciales est interdite. Cette droits couvrent l'ensemble des données sur ce document ainsi que son contenu. Toute utilisation ou de copie de ce document, en totalité ou en partie, doit inclure le nom de l'auteur.
Date de Publication
2016-10-10
 
AVERTISSEMENT: Apprenez ce que sont des œvres dérivées cliquant ici.
Tous droits de la thèse/dissertation appartiennent aux auteurs
CeTI-SC/STI
Bibliothèque Numérique de Thèses et Mémoires de l'USP. Copyright © 2001-2024. Tous droits réservés.