• JoomlaWorks Simple Image Rotator
  • JoomlaWorks Simple Image Rotator
  • JoomlaWorks Simple Image Rotator
  • JoomlaWorks Simple Image Rotator
  • JoomlaWorks Simple Image Rotator
  • JoomlaWorks Simple Image Rotator
  • JoomlaWorks Simple Image Rotator
  • JoomlaWorks Simple Image Rotator
  • JoomlaWorks Simple Image Rotator
  • JoomlaWorks Simple Image Rotator
 
  Bookmark and Share
 
 
Tesis Doctoral
DOI
https://doi.org/10.11606/T.98.2012.tde-21052012-080942
Documento
Autor
Nombre completo
Pier Marco Ricchetti
Dirección Electrónica
Instituto/Escuela/Facultad
Área de Conocimiento
Fecha de Defensa
Publicación
São Paulo, 2011
Director
Tribunal
Andrade, Aron Jose Pazin de (Presidente)
Alvarenga, Milkes Yone
Furuie, Sergio Shiguemi
Nicolosi, Denys Emilio Campion
Paula, Silvia Maria de
Título en portugués
Aplicação de técnicas matemáticas avançadas para auxílio a diagnóstico em imagens na detecção de fraturas em stents.
Palabras clave en portugués
Algoritmos.
Diagnóstico por Imagem
Filtros/Métodos
Stent
Resumen en portugués
O implante de stents em região vascular periférica tem sido apontado como uma solução para o tratamento endovascular, e tem sido largamente utilizado. No entanto, há estudos que apontam com certa frequência a ocorrência de problemas ligados a fraturas de stents, as quais devem ser diagnosticadas e convenientemente tratadas. Na região femoropoplítea, por exemplo, foi detectada a ocorrência de 32% de fraturas em um conjunto de 121 tratamentos, conforme aponta pesquisa realizada. O diagnóstico de tais fraturas é normalmente feito a partir de análise visual de imagens, as quais muitas vezes apresentam ruídos e deformidades decorrentes do método empregado para a sua captura, dificultando a correta visualização de sua estrutura e deformidades. A escassez de recursos e estudos que permitam a automatização deste processo motivaram a realização deste trabalho, em que são desenvolvidas técnicas que melhoram a visualização dos elementos de imagem de forma a facilitar o diagnóstico de observação e, quando possível, apontar regiões de possíveis fraturas. Para isto, a utilização de elementos computacionais clássicos e o desenvolvimento de técnicas adicionais inéditas contribuem para a análise de imagens, fornecendo um possível direcionamento como forma de auxílio ao diagnóstico médico. Os métodos desenvolvidos são aplicados a amostras de imagens, e os resultados obtidos são comparados àqueles do diagnóstico médico. Como resultado obteve-se, além da melhoria de visualização das imagens, um índice de concordância Kappa de 0,878 para a detecção de fraturas, o que confirma o método como satisfatório e de concordância bastante relevante.
Título en inglés
Advanced mathematics application to aid the diagnosis of images in stent fractures detection.
Palabras clave en inglés
Algorithm.
Filters/Methods
Image Diagnosis
Stent
Resumen en inglés
The insert of stents in peripheral vascular region has been considered as a solution for endovascular treatment, and has been widely used. However, there are studies that show, with a certain frequency, the occurrence of problems related to stent fractures, which should be diagnosed and properly treated. In the femoropopliteal region, for example, it was detected 32% of fractures in a set of 121 treatments, as shown by survey. The diagnosis of such fractures is usually made from visual analysis of images, which often shows noise and deformation resulting from the method employed for capture, making difficulty to the correct visualization of its structure and deformities. The lack of resources and studies that allows to automate this process, motivated this work, in which techniques are developed that improve the display of the image elements in order to facilitate the diagnosis by observation and, when possible, pointing out areas of possible fractures. For this, the use of classical elements and the development of additional computational techniques contribute to innovate image analysis, providing a possible direction as a way to aid medical diagnosis. The developed methods are applied to images samples and the results are compared to those of medical diagnosis. As a result obtained, as well as the improved display of images, a Kappa concordance index of 0.878 for the detection of fractures confirms the method as satisfactory and a quite relevant agreement.
 
ADVERTENCIA - La consulta de este documento queda condicionada a la aceptación de las siguientes condiciones de uso:
Este documento es únicamente para usos privados enmarcados en actividades de investigación y docencia. No se autoriza su reproducción con finalidades de lucro. Esta reserva de derechos afecta tanto los datos del documento como a sus contenidos. En la utilización o cita de partes del documento es obligado indicar el nombre de la persona autora.
Fecha de Publicación
2012-06-19
 
ADVERTENCIA: Aprenda que son los trabajos derivados haciendo clic aquí.
Todos los derechos de la tesis/disertación pertenecen a los autores
CeTI-SC/STI
Biblioteca Digital de Tesis y Disertaciones de la USP. Copyright © 2001-2024. Todos los derechos reservados.