• JoomlaWorks Simple Image Rotator
  • JoomlaWorks Simple Image Rotator
  • JoomlaWorks Simple Image Rotator
  • JoomlaWorks Simple Image Rotator
  • JoomlaWorks Simple Image Rotator
  • JoomlaWorks Simple Image Rotator
  • JoomlaWorks Simple Image Rotator
  • JoomlaWorks Simple Image Rotator
  • JoomlaWorks Simple Image Rotator
  • JoomlaWorks Simple Image Rotator
 
  Bookmark and Share
 
 
Thèse de Doctorat
DOI
https://doi.org/10.11606/T.98.2012.tde-07122012-110520
Document
Auteur
Nom complet
Manuel Nicolas Cano
Adresse Mail
Unité de l'USP
Domain de Connaissance
Date de Soutenance
Editeur
São Paulo, 2012
Directeur
Jury
Sousa, José Eduardo Moraes Rego (Président)
Amorim, Jorge Eduardo de
Caldas, José Guilherme Mendes Pereira
Kambara, Antonio Massamitsu
Portela, Luiz Antonio Pezzi
Titre en portugais
Estudo randomizado comparando dois dispositivos de proteção cerebral no implante de stent carotídeo: avaliação de novos focos isquêmicos através das sequências de difusão por ressonância magnética.
Mots-clés en portugais
Doença das artérias carótidas
Ensaio clínico controlado aleatório
Imagem de difusão por ressonância magnética
Stents
Resumé en portugais
Introdução: O Stent Carotídeo (SC) surgiu como uma alternativa à cirurgia de endarterectomia para o tratamento de estenose carotídea extracraniana com o objetivo de prevenir o acidente vascular encefálico (AVE). O sucesso do SC depende de estratégias que minimizem o risco de AVE. No início do estudo não existiam estudos randomizados comparando o implante de stent carotídeo com diferentes tipos de proteção cerebral. Objetivos: Testar de forma aleatória a eficácia de dois diferentes princípios de proteção embólica no território carotídeo (Angioguard®) e Mo.Ma), utilizando a ressonância magnética ponderada em Difusão (RM-PD) para detectar novas lesões isquêmicas no encéfalo analisando número, tamanho e localização. Métodos: Sessenta pacientes submetidos ao implante do stent carotídeo (SC), foram alocados aleatoriamente para utilizar filtro distal Angioguard® (30 pacientes) e balão de oclusão proximal Mo.Ma (30 pacientes) desde julho de 2008 a 2011. Todos os pacientes realizaram RM-PD pré e 48 horas pós o SC. Os resultados foram avaliados por neurologista independente e cego ao tipo de proteção cerebral utilizada. Foram acompanhados por um período de pelo menos um ano. Os dados qualitativos foram resumidos em frequências absolutas e relativas (porcentagens) e comparados utilizando o teste quiquadrado com correção de continuidade de Yates ou o teste exato de Fisher. Os dados quantitativos foram expressos em médias e desvio-padrão, e/ou medianas e intervalos interquartis e foram comparadas utilizando o teste t de Student ou não paramétrico de Mann-Whitney. Resultados: Não houve diferença estatisticamente significativa em quanto a antecedentes clínicos ou características das lesões carotídeas entre os grupos, apenas as lesões eram mais calcificadas no grupo Angioguard® (p < 0,01). Não houve diferença entre os grupos quanto a incidência de novas lesões isquêmicas (63,3% do Angioguard® vs 66,7% do Mo.Ma, p = 0,787). Quando presentes, as lesões isquêmicas por pacientes o fizeram em número significativamente menor no grupo Mo.Ma, entre 1 e 43 lesões (mediana = 6), comparado ao grupo AngioguardÒ, entre 1 e 76 lesões (mediana = 10) com p < 0,001. Três pacientes (5%) apresentaram eventos neurológicos em até 30 dias e no seguimento de um ano, 1 paciente teve um infarto agudo do miocárdio. Conclusão: Foram observadas novas lesões isquêmicas cerebrais em mais de 60% dos pacientes que utilizaram os dois dispositivos de proteção cerebral, entretanto houve significativamente menos lesões por paciente no grupo Mo.Ma, com significância estatística p = < 0,001. A maioria das lesões foi pequena < 0,5 mm, e encontradas em território ipsilateral. Não foi observado óbito ou AVE maior no seguimento de pelo menos um ano.
Titre en anglais
A randomized study comparing two cerebral protection devices in carotid artery stenting: evaluation of new ischemic lesions through the sequence of diffusion weighted magnetic resonance imaging
Mots-clés en anglais
Carotid artery disease
Image diffusion-weighted MRI
Randomized controlled clinical trial
Stents
Resumé en anglais
Background: Carotid Stent (CAS) has emerged as an alternative to surgical carotid endarterectomy for the treatment of extracranial carotid stenosis in order to prevent stroke. The success of the CAS depends on estrategies that minimize the risk of stroke. When this study began there were no randomized trial comparing different types of cerebral protection during carotid stenting. Objectives: Randomly test the effectiveness of two different embolic protection principles in carotid artery (Angioguard®) vs Mo.Ma) using diffusion-weighted magnetic resonance imaging (DWI) to detect new ischemic lesions in the brain, analyzing the number, size and location of this new ischemic lesions between groups. Methods: Sixty patients undergoing CAS, were randomly assigned to use distal filter AngioguardÒ (30p) and proximal balloon occlusion Mo.Ma (30p) from July 2008 to July 2011. All patients underwent DWI before and 48 hours after the CAS. The results were evaluated by an independent neuroradiologist blind to the type of cerebral protection used. The patients were followed during at least year. Qualitative data were summarized as absolute and relative frequencies (percentages) and compared using chisquare test with Yates continuity correction or Fisher's exact test. Quantitative data were expressed as means and standard deviations, and / or medians and interquartile ranges and were compared using the Student t test or nonparametric Mann-Whitney test. Results: Demographic, clinical and lesion characteristics were not different between the two groups, there were more calcified lesion in the Angioguard® group (p < 0.001). There was no difference between groups regarding the incidence of new ischemic lesions in the Angioguard® group compared to the Mo.Ma group (63.3% vs 66.7% p = 0.787). When present, the number of ischemic cerebral lesions per pacient were in fewer number in the Mo.Ma group (1 to 43 lesions; median = 6) compared to the Angioguard® group (1 to 76 lesions; median = 10) p < 0.001 and this difference was significant. Three patients (5%) had neurological events within 30 days with complete regression of symptoms, and one patient develop an infarction during the first year of follow-up. Conclusions: There were new cerebral ischemic lesions detected by DWI in more than 60% of the patients in both groups, on the other hand there were significantly fewer lesions per patient in those allocated to Mo.Ma as compared to Angioguard® with statistical significance p = 0.001. Most lesions were small < 0.5mm, and localized in ipsilateral territory. There was no death or disabling stroke in at least one year of follow-up.
 
AVERTISSEMENT - Regarde ce document est soumise à votre acceptation des conditions d'utilisation suivantes:
Ce document est uniquement à des fins privées pour la recherche et l'enseignement. Reproduction à des fins commerciales est interdite. Cette droits couvrent l'ensemble des données sur ce document ainsi que son contenu. Toute utilisation ou de copie de ce document, en totalité ou en partie, doit inclure le nom de l'auteur.
Date de Publication
2013-01-09
 
AVERTISSEMENT: Apprenez ce que sont des œvres dérivées cliquant ici.
Tous droits de la thèse/dissertation appartiennent aux auteurs
CeTI-SC/STI
Bibliothèque Numérique de Thèses et Mémoires de l'USP. Copyright © 2001-2024. Tous droits réservés.