Thèse de Doctorat
DOI
https://doi.org/10.11606/T.98.2012.tde-03082012-070905
Document
Auteur
Nom complet
Flavio Roberto Azevedo de Oliveira
Adresse Mail
Unité de l'USP
Domain de Connaissance
Date de Soutenance
Editeur
São Paulo, 2012
Directeur
Jury
Mattos, Luiz Alberto Piva e (Président)
Chaves, Áurea Jacob
Alves, Claudia Maria Rodrigues
Devito, Fernando Stuchi
Mangione, José Armando
Titre en portugais
Avaliação da eficácia tardia após o implante de um stent miniaturizado, farmacológico versus não-farmacológico, em artérias coronárias de pequeno calibre
Mots-clés en portugais
Angiografia coronária
Estudo comparativo
Stents
Stents farmacológicos
Resumé en portugais
Os vasos de fino calibre apresentam maior risco para reestenose e revascularização da lesão alvo. Limitações relacionadas com a navegabilidade dos sistemas de dilatação por balão e menor capacidade de acomodação da neoíntima podem contribuir para isto. O stent autoexpansível de nitinol Sparrow® dedicado a vaso de calibre < 2,75 mm, resultou num conjunto com perfil de um fio-guia 0,014". Testado na forma de stent de metal puro no estudo CARE I, revelou-se seguro e eficaz em vasos de fino calibre. Este estudo avaliou, de forma pioneira, o despenho de um stent autoexpansível farmacológico neste cenário. O objetivo primário foi comparar a perda luminal tardia no vaso-alvo pela angiografia coronária quantitativa ao final de oito meses, entre os stents Sparrow® farmacológico e não farmacológico, em coronárias com diâmetro de referência < 2,75 mm. Casuística e métodos: Os pacientes foram randomizados de forma prospectiva em dois grupos para procedimento de angioplastia: um grupo com o emprego o stent Sparrow® farmacológico (sirolimus), e ou outro grupo com o stent Sparrow® na versão não farmacológica. Análise pela angiografia coronária quantitativa foi realizada imediatamente antes e após o procedimento e aos oito meses, com seguimento clínico de 24 meses. Foi utilizado o programa IBM SPSS Statistics® para análise estatística e foi considerado nível de significância de 5% e poder de 80% para o cálculo do tamanho da amostra. Resultados: 24 pacientes foram randomizados, 12 no grupo com stent farmacológico Sparrow® e 12 no grupo com a versão não farmacológica. Na avaliação angiográfica aos oito meses verificou-se significativa redução de perda luminal tardia no grupo com o stent farmacológico Sparrow® em comparação com grupo com a versão não farmacológica (0,25 + 0,16 mm versus 0,97 + 0,76 mm, p = 0,008, IC 95% de -1,19 ; -0,22). No seguimento clínico de 12 meses, não foram observados eventos cardíacos adversos maiores (morte, infarto ou necessidade de revascularização do vaso alvo) no grupo com stent farmacológico. Não ocorreu trombose intrastent. Conclusão: Em pacientes submetidos à angioplastia transluminal percutânea em artérias coronárias com diâmetro de referência < 2,75 mm, o emprego do stent farmacológico autoexpansível Sparrow®, em comparação com a versão não farmacológica do mesmo stent, resultou em significativa redução de perda luminal tardia, sem ocorrência de eventos clínicos que deponham contra a segurança do dispositivo pesquisado.
Titre en anglais
Evaluating the effectiveness late after implantation of a miniaturized drug eluting stent versus a bare metal stent with the same platform in percutaneous coronary angioplasty of small vessels
Mots-clés en anglais
Comparative study
Coronary angiography
Drug-eluting stents
Stents
Resumé en anglais
Small vessels represent a group with high risk for restenosis and target lesion revascularization. Limitations associated with navigability of balloon dilation systems and less accommodating of the neointima may contribute to this. The self-expanding Sparrow® stent system dedicated to the vessel size <2.75 mm resulted in a profile similar to a 0.014" guide wire angioplasty. Tested as bare metal stent in the CARE trial I, the Sparrow® stent system has proved to be safe and effective in small vessels. This study evaluated, for the first time, the performance of a self-expanding drug eluting stent in this scenario. The primary objective was to compare the in-stent late lumen loss by quantitative coronary angiography at the end of eight months between the Sparrow® drug-elutig stent and Sparrow® bare metal stent in coronary arteries with reference diameter <=2.75 mm. Materials and methods: Patients were prospectively randomized (1:1) Analysis by quantitative coronary angiography was performed immediately before and after the procedure and at eight months with clinical follow-up to 12 months. We used the IBM® SPSS for statistical analysis and was considered a significance level of 5% and 80% power for the calculation of sample size. Results: 24 patients were randomized, 12 in each group. At Eight months follow-up there was significant reduction in late lumen loss in the Sparrow® drug-eluting stent group compared to the Sparrow® bare metal stent group (0.25 ± 0.16 mm vs. 0.97 + 0.76 mm, p = 0.008, 95% CI -1.19 to -0.22). Up to 12 months of clinical follow-up there no cases of death, myocardial infarction and target vessel revascularization Of note, there was no stent thrombosis. Conclusion: In patients undergoing percutaneous transluminal angioplasty in coronary arteries with reference diameter <= 2.75 mm, the use of Sparrow® drug-eluting stent, compared to the Sparrow® bare metal stent, resulted in significant less late loss without occurrence of clinical events that weigh against the security of device.
 
AVERTISSEMENT - Regarde ce document est soumise à votre acceptation des conditions d'utilisation suivantes:
Ce document est uniquement à des fins privées pour la recherche et l'enseignement. Reproduction à des fins commerciales est interdite. Cette droits couvrent l'ensemble des données sur ce document ainsi que son contenu. Toute utilisation ou de copie de ce document, en totalité ou en partie, doit inclure le nom de l'auteur.
Date de Publication
2012-08-03
 
AVERTISSEMENT: Apprenez ce que sont des œvres dérivées cliquant ici.
Tous droits de la thèse/dissertation appartiennent aux auteurs
CeTI-SC/STI
Bibliothèque Numérique de Thèses et Mémoires de l'USP. Copyright © 2001-2024. Tous droits réservés.