Disertación de Maestría
DOI
https://doi.org/10.11606/D.97.2008.tde-22082013-104314
Documento
Autor
Nombre completo
Wolney de Jesus Jardim
Dirección Electrónica
Instituto/Escuela/Facultad
Área de Conocimiento
Fecha de Defensa
Publicación
Lorena, 2008
Director
Tribunal
Silva, Maria Lúcia Caetano Pinto da (Presidente)
Correa, Sergio Machado
Giordani, Domingos Savio
Título en portugués
Construção e avaliação de eletrodos de Nióbio/Óxido de Nióbio para determinações potenciométricas
Palabras clave en portugués
Eletrodo
Nióbio/Óxido de Nióbio
Potenciometria
Resumen en portugués
A construção de sensor potenciométrico, utilizando Nióbio acoplado a eletrodo de referência de prata/cloreto de prata num mesmo instrumento, possibilita o acompanhamento da variação de potencial que ocorre durante uma reação ácido-base em meio aquoso. Foi utilizado eletrodo de vidro combinado, cuja membrana de vidro foi danificada fisicamente, porém com sua referência interna em pleno funcionamento. O eletrodo de Nióbio foi confeccionado com metal polido ou então com a superfície modificada com óxido eletrodepositado. O crescimento de óxido sobre o Nióbio foi obtido por eletrólise em meio a H3PO4 diluído. O metal ou o par metal/óxido foi fixado no eletrodo de vidro contendo uma solução eletrolítica. O eletrodo de Nióbio não apresenta boa sensibilidade quando utilizado como indicador em potenciometria direta, mas é sensível às variações de potenciais que ocorrem em titulações ácido-base. O eletrodo de Nióbio metálico pode substituir o eletrodo de vidro combinado na determinação do teor de acidez de vinagres.
Título en inglés
Construction and evalution of Niobium/Niobium Oxide electrodes for potentiometric determination
Palabras clave en inglés
Electrode
Niobium/Niobium Oxide
Potentiometry
Resumen en inglés
The construction of potentiometric sensors, using Niobium combined with the reference electrode silver / silver chloride in a single instrument, allows the variation of potential monitoring that occurs during an acid-base reaction in aqueous media. It was used a combined electrode glass, whose glass membrane was damaged physically, but with the internal reference in full operation. The Niobium electrode was made with polished metal or with the surface modified by electrodeposited oxide. The oxide growth was obtained by electrolysis in the H3PO4 diluted media. The metal or metal/oxide was fixed in glass electrode containing a electrolyte solution. The Niobium electrode doesn't show sensitivity when used as an indicator in direct potentiometry, but is sensitive to changes of potential that occur in acid-base titrations. The electrode of Niobium metal can replace the glass electrode combined in determining the level of acidity of vinegar.
 
ADVERTENCIA - La consulta de este documento queda condicionada a la aceptación de las siguientes condiciones de uso:
Este documento es únicamente para usos privados enmarcados en actividades de investigación y docencia. No se autoriza su reproducción con finalidades de lucro. Esta reserva de derechos afecta tanto los datos del documento como a sus contenidos. En la utilización o cita de partes del documento es obligado indicar el nombre de la persona autora.
EQD08005.pdf (10.18 Mbytes)
Fecha de Publicación
2013-08-22
 
ADVERTENCIA: Aprenda que son los trabajos derivados haciendo clic aquí.
Todos los derechos de la tesis/disertación pertenecen a los autores
CeTI-SC/STI
Biblioteca Digital de Tesis y Disertaciones de la USP. Copyright © 2001-2024. Todos los derechos reservados.