• JoomlaWorks Simple Image Rotator
  • JoomlaWorks Simple Image Rotator
  • JoomlaWorks Simple Image Rotator
  • JoomlaWorks Simple Image Rotator
  • JoomlaWorks Simple Image Rotator
  • JoomlaWorks Simple Image Rotator
  • JoomlaWorks Simple Image Rotator
  • JoomlaWorks Simple Image Rotator
  • JoomlaWorks Simple Image Rotator
  • JoomlaWorks Simple Image Rotator
 
  Bookmark and Share
 
 
Thèse de Doctorat
DOI
https://doi.org/10.11606/T.97.2019.tde-28052019-151521
Document
Auteur
Nom complet
Beatriz Zuleika de Macedo
Adresse Mail
Unité de l'USP
Domain de Connaissance
Date de Soutenance
Editeur
Lorena, 2018
Directeur
Jury
Schneider, Sandra Giacomin (Président)
Afonso, Conrado Ramos Moreira
Couto, Antonio Augusto
Rodrigues Junior, Durval
Zavaglia, Cecília Amélia de Carvalho
Titre en portugais
Estudo do comportamento em fadiga de alto ciclo da liga Ti-35Nb-7Zr para aplicações biomédicas
Mots-clés en portugais
Biomateriais
Fadiga de alto ciclo
Ligas Ti-?
Propriedades Mecânicas
Propriedades Microestruturais
Tratamento térmico ultrarrápido
Resumé en portugais
Ligas de titânio do tipo ??compostas de elementos não tóxicos são materiais com potencial para aplicações biomédicas por apresentarem baixo módulo de elasticidade, efeito de memória de forma, biocompatibilidade satisfatória e boa conformabilidade. Para os biomateriais, o conhecimento das propriedades de fadiga é essencial para garantir uma alta confiabilidade para implantes ortopédicos e odontológicos. As propriedades mecânicas dependem diretamente do processamento termomecânico, da taxa de resfriamento imposta à liga e da composição química, que são fatores responsáveis pela determinação de sua microestrutura. Neste contexto, neste trabalho foi avaliado o comportamento em fadiga da liga Ti-35Nb-7Zr (% em p.) para aplicações biomédicas. Trata-se de uma liga de titânio do tipo ??e a motivação desse estudo baseou-se em complementar resultados de suas propriedades microestruturais e mecânicas obtidos em estudos anteriores realizados no DEMAR - EEL/USP. A liga foi produzida por fusão a arco a partir de materiais (Ti, Nb, Zr) de pureza comercial. A rota de processamento termomecânico envolveu as etapas de tratamento térmico de solubilização, forjamento rotativo a frio, tratamento térmico de recristalização. Um tratamento térmico ultrarrápido (Flash) foi adicionado para promover o refino de grãos e aumento da resistência mecânica. A caracterização microestrutural foi realizada por técnicas de microscopia óptica, microscopia eletrônica de varredura, microscopia eletrônica de transmissão, difratometria de raios X e medidas de dureza Vickers. As propriedades mecânicas foram investigadas por ensaios de tração uniaxial e ensaios de fadiga de alto ciclo por flexão rotativa de corpos de prova lisos e entalhados. Com relação ao conjunto de propriedades, os melhores resultados podem ser considerados para a condição recristalizada à 1000ºC/2h + flash. Os resultados obtidos neste trabalho confirmam a possibilidade de uso da liga Ti-35Nb-7Zr para aplicações biomédicas.
Titre en anglais
Study of the high cycle fatigue behavior of Ti-35Nb-7Zr alloy for biomedical applications
Mots-clés en anglais
Biomaterials
de Ti-? alloys
Flash thermal treatment
High cycle fatigue
Mechanical Properties
Microstructural Properties
Resumé en anglais
?-type titanium alloys composed of non-toxic elements are materials with potential for biomedical applications because they have low elastic modulus, shape memory effect, satisfactory biocompatibility and good workability. For biomaterials, knowledge of fatigue properties is essential to ensure high reliability for orthopedic and dental implants. The mechanical properties depend directly on thermomechanical processing, alloy cooling rate and chemical composition, which are responsible for the determination of its microstructure. In this context, this work was evaluated the fatigue behavior of the Ti- 35Nb-7Zr alloy (wt. %) for biomedical applications. It is a ?-type alloy and the motivation of this study was based on complementing the results of its microstructural and mechanical properties previously obtained at DEMAR-EEL/USP. The alloy was produced from materials of commercial purity (Ti, Nb and Zr) by arc meling. The thermomechanical processing route consisted the steps of solubilization heat treatment, cold rotary forging, recrystallization heat treatment. A ultrafast thermal treatment (Flash) was additioned to promote the grain refinement and to increase mechanical strength. The microstructural characterization was done by optical microscopy, scanning electron microscopy, transmission electron microscopy, X ray diffraction techniques and Vickers microhardness tests. The mechanical properties was investigated by uniaxial tensile tests and rotary bending high cycle fatigue tests of smooth and notched specimens. With respect to the set of properties, the best results can be considered for recrystalized condition at 1000ºC/2h + flash. The results obtained in this work confirm the possibility of using the Ti-35Nb-7Zr alloy for biomedical applications.
 
AVERTISSEMENT - Regarde ce document est soumise à votre acceptation des conditions d'utilisation suivantes:
Ce document est uniquement à des fins privées pour la recherche et l'enseignement. Reproduction à des fins commerciales est interdite. Cette droits couvrent l'ensemble des données sur ce document ainsi que son contenu. Toute utilisation ou de copie de ce document, en totalité ou en partie, doit inclure le nom de l'auteur.
EMT18004_C.pdf (19.95 Mbytes)
Date de Publication
2019-05-28
 
AVERTISSEMENT: Apprenez ce que sont des œvres dérivées cliquant ici.
Tous droits de la thèse/dissertation appartiennent aux auteurs
CeTI-SC/STI
Bibliothèque Numérique de Thèses et Mémoires de l'USP. Copyright © 2001-2024. Tous droits réservés.