Avaliação da atividade mutagênica de águas superficiais utilizadas para abastecimento público após tratamento na bacia dos rios Piracicaba, Capivari e Jundiaí
Palabras clave en portugués
Abastecimento de água (Cuidados)
Água de superfície (Análise)
Água fluvial (Análise)
Águas
Monitoramento
Mutagênese
Teste de Salmonella/microssoma
Tratamento de água
Resumen en portugués
Compostos mutagênicos/genotóxicos podem não ser removidos durante os processos convencionais de tratamento de água para consumo humano e podem provocar mutações em células somáticas e/ou germinativas, o que pode trazer agravos à saúde humana. O objetivo deste trabalho foi avaliar a atividade genotóxica em águas brutas coletadas em seis locais (Itatiba, Valinhos, Sumaré, Indaiatuba, Jundiaí e Artur Nogueira) onde ocorre captação para abastecimento público, na bacia dos rios Piracicaba, Capivari e Jundiaí (Estado de São Paulo), que não têm sua mutagenicidade caracterizada. Foi empregado o teste de Salmonella/microssoma, combinado a processos de extração orgânica (resina XAD), com as linhagens TA98, TA100 e YG1042. A linhagem YG1041 teve seu uso avaliado no monitoramento de águas superficiais. Foram avaliados também diferentes critérios de positividade para o teste e emprego de diferentes doses máximas testadas. Quatro captações avaliadas apresentaram resultados negativos enquanto as captações de Sumaré e Valinhos apresentaram atividade mutagênica. O ribeirão Jacaré foi identificado como uma das fontes da mutagenicidade impactando na captação de Valinhos. A potência máxima detectada, na captação de Sumaré, atingiu 1020 rev/L para a linhagem TA98 na ausência de ativação metabólica e 2600 rev/L para a TA100 com ativação metabólica, potências consideradas moderada e alta, respectivamente. Estes resultados levaram à inclusão do teste de Salmonella/microssoma no monitoramento realizado pela CETESB nas captações de Valinhos e Sumaré a partir de 2006.
Título en inglés
Mutagenic activity assessment of surface water used as source for drinking water at Piracicaba, Capivari and Jundiaí river systems
Palabras clave en inglés
Monitoring program
Mutagenicity
Salmonella test
Water
Water treatment
Resumen en inglés
Mutagenic/genotoxic compounds may persist after conventional treatment for drinking water production and may induce mutations on somatic or germinative cells which can lead to human health damage. The objetive of this study was to evaluate the genotoxic activity in surface water samples at 6 sites (Itatiba, Valinhos, Sumaré, Indaiatuba, Jundiaí and Artur Nogueira) located at Piracicaba, Capivari and Jundiaí river systems (São Paulo state). These sites are used as source for drinking water and were not previously screened for mutagenic activity. The organic extract (XAD resin) was tested for mutagenicity with the Salmonella assay using TA98, TA100 and YG1042 strains and YG1041 strain had its use in surface water evaluated. Different criteria for analyzing Salmonella/microsoma assay data were also evaluated as well as the use of different highest doses. Four evaluated sites elicited negative results while Sumaré and Valinhos samples presented mutagenic activity. Jacaré river was identififed as one of the mutagenic sources with impact on Valinhos drinking water source. Maximum mutagenic potency, detected at Sumaré water source, were 1020 rev/L for TA98 in the absence of S9 mix and 2600 rev/L for TA100 in the presence of S9 mix. These potency values are classified as moderate and high, respectively. These results lead to the inclusion of the Salmonella/microsoma assay into the monitoring program performed by CETESB (São Paulo State Environmental Protection Agency) at Valinhos and Sumaré from 2006 on.
 
ADVERTENCIA - La consulta de este documento queda condicionada a la aceptación de las siguientes condiciones de uso:
Este documento es únicamente para usos privados enmarcados en actividades de investigación y docencia. No se autoriza su reproducción con finalidades de lucro. Esta reserva de derechos afecta tanto los datos del documento como a sus contenidos. En la utilización o cita de partes del documento es obligado indicar el nombre de la persona autora.
Fecha de Publicación
2013-06-26
 
ADVERTENCIA: Aprenda que son los trabajos derivados haciendo clic aquí.
Todos los derechos de la tesis/disertación pertenecen a los autores
CeTI-SC/STI
Biblioteca Digital de Tesis y Disertaciones de la USP. Copyright © 2001-2024. Todos los derechos reservados.