• JoomlaWorks Simple Image Rotator
  • JoomlaWorks Simple Image Rotator
  • JoomlaWorks Simple Image Rotator
  • JoomlaWorks Simple Image Rotator
  • JoomlaWorks Simple Image Rotator
  • JoomlaWorks Simple Image Rotator
  • JoomlaWorks Simple Image Rotator
  • JoomlaWorks Simple Image Rotator
  • JoomlaWorks Simple Image Rotator
  • JoomlaWorks Simple Image Rotator
 
  Bookmark and Share
 
 
Mémoire de Maîtrise
DOI
https://doi.org/10.11606/D.9.2001.tde-27082012-161157
Document
Auteur
Nom complet
Andréia Peraro do Nascimento
Adresse Mail
Unité de l'USP
Domain de Connaissance
Date de Soutenance
Editeur
São Paulo, 2001
Directeur
Jury
Kedor, Erika Rosa Maria (Président)
Araujo, Magali Benjamin de
Santoro, Maria Inês Rocha Miritello
Titre en portugais
Estabilidade física e metodologia analítica para formulações farmacêuticas contendo cetoconazol
Mots-clés en portugais
Análise de medicamentos e cosméticos
Antifúngicos (Farmacologia)
Cetoconazol
Controle de qualidade
Cromatografia líquida
Espectrofotometria derivada
Medicamento
Química farmacêutica
Resumé en portugais
O cetoconazol é um derivado imidazólico com atividade antifúngica, empregado no tratamento de grande variedade de infecções cutâneas. O objetivo deste trabalho foi a padronização e a validação dos métodos analíticos empregando-se a espectrofotometria no ultravioleta ( UV ) por derivada de primeira ordem e a cromatografia líquida de alta eficiência (CLAE) para a determinação do cetoconazol em formulações farmacêuticas sob a forma de creme obtidas no comércio e formuladas em laboratório. O estudo da estabilidade física das formulações obtidas em laboratório foi realizado após o armazenamento sob diferentes condições de tempo, temperatura e umidade. O método espectrofotométrico no UV por derivada de primeira ordem foi padronizado a 257nm , no intervalo de concentração de 5,0 a 30,0 µg/mL em metanol. O coeficiente de correlação linear foi de 0,9997, o percentual de recuperação foi de 100,24%. A média do desvio padrão relativo foi de 0,56% para a amostra simulada e 0,41% para a amostra comercial. A determinação de cetoconazol por CLAE foi realizada empregando-se uma coluna LiChrospher® 100 RP- 18 ( 5µm ) e fase móvel constituída por uma mistura de trietilamina em metanol( 1:500 ) e solução de acetato de amônio em água (1:200 ) na proporção de 75 : 25 v/v, com vazão de 1,0 mL/min e detecção no UV a 225 nm. O terconazol foi utilizado como padrão interno. O coeficiente de correlação linear foi de 0,9981, o percentual de recuperação foi de 100,88%, a média do desvio padrão foi de 2,13% para a amostra simulada e 1,25% para a amostra comercial. A amostra simulada apresentou comportamento pseudoplástico e tixotropia em decorrência das medidas reológicas obtidas experimentalmente.
Titre en anglais
Study the stability and analytical methods to determine ketoconazole in dosage forms preparations
Mots-clés en anglais
Antifungal (Pharmacology)
Derivative spectrophotometry
Drugs
Ketoconazole
Liquid chromatography
Pharmaceutical chemistry
Quality control
Resumé en anglais
Ketoconazole is an imidazole antifungal agent used in the treatment of great variety of skin infectious diseases. The aim of this research was the standardization and the validation of two analytical methods, first derivative ultraviolet ( UV ) spectrophotometry and high performance liquid chromatography( HPLC ) to determine ketoconazole in commercial and simulated cream dosage forms preparations. The validated methods were used to study the stability of the simulated cream after storage under high temperatures and high percentage of humidity. First derivative UV spectrophotometry was standardized at 257 nm, in a range of concentration from 5.0 to 30.0 µg/mL in methanol. The coefficient of correlation was 0.9997 and the recovery average was 100.24%. The average relative standard deviation ( RSD ) was 0.56% for simulated preparation and 0.41 % for commercial preparation. The determination of ketoconazole by HPLC was performed using a LiChrospher® 100 RP-18(5µm ) column, a mobile phase consisting of triethylamine in methanol (1:500) and ammonium acetate solution in water(1:200 ) 75:25 ( v/v ), a flow rate of 1.0 mL/min and UV detection at 225nm. Terconazole was used as internal standard. The coefficient of correlation was 0.9981, the recovery average was 100.88%, the average relative standard deviation ( RSD ) was 2.13% for the simulated preparations and 1.25% for the commercial preparations. The rheological measurements showed that the simulated preparation presented pseudoplastic and thixotropic behavior.
 
AVERTISSEMENT - Regarde ce document est soumise à votre acceptation des conditions d'utilisation suivantes:
Ce document est uniquement à des fins privées pour la recherche et l'enseignement. Reproduction à des fins commerciales est interdite. Cette droits couvrent l'ensemble des données sur ce document ainsi que son contenu. Toute utilisation ou de copie de ce document, en totalité ou en partie, doit inclure le nom de l'auteur.
Date de Publication
2012-08-27
 
AVERTISSEMENT: Apprenez ce que sont des œvres dérivées cliquant ici.
Tous droits de la thèse/dissertation appartiennent aux auteurs
CeTI-SC/STI
Bibliothèque Numérique de Thèses et Mémoires de l'USP. Copyright © 2001-2024. Tous droits réservés.